Performance evaluation of siemens CTI ECAT EXACT 47 PET scanner using NEMA NU2-2001

被引:0
|
作者
Kim, JS [1 ]
Lee, JS [1 ]
Lee, DS [1 ]
Jung, JK [1 ]
Lee, MC [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul, South Korea
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner was measured using NEMA NU2-2001 standard. ECAT EXACT 47 is a BGO crystal based PET scanner. Coincidence window are set to 12 ns, and energy window are set to 250 similar to 650 keV. For the spatial resolution measurement, F-18 point source was placed at 1cm and 10 cm offset from the center of transaxial FOV. Images were reconstructed using FBP with ramp filter. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by 1 similar to 5 aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity were estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 solution (2D: 2,900 MBq), and coincidence count rates were measured for 7 half-lives to obtain noise equivalent count rate (NECR) and scatter fraction. Transverse and axial resolutions at 1cm offset from the center were 9.1 and 9.8 mm (FBP, 2D and 3D), Sensitivity values were 709 (2D), 3332 (3D) cps/MBq at the center and 796(2D), 4050 (3D) cps/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D). Peak true count rate and NECR were 64.0 kcps@37.5 kBq/mL and 49.6 kcps@37.5 kBq/mL in 2D. Information about the performance of EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.
引用
收藏
页码:3118 / 3120
页数:3
相关论文
共 50 条
  • [31] Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard
    Rausch, Ivo
    Ruiz, Agustin
    Valverde-Pascual, Itziar
    Cal-Gonzalez, Jacobo
    Beyer, Thomas
    Carrio, Ignasi
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (04) : 561 - 567
  • [32] Scatter Fraction, Count Rates, and Noise Equivalent Count Rate of an RPC TOF- PET System: Simulation Study Following the NEMA NU2-2001 Standards
    Couceiro, Miguel
    Crespo, Paulo
    Marques, Rui Ferreira
    Fonte, Paulo
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2651 - 2660
  • [33] NEMA NU4 performance evaluation of the SynchroPET human arterial PET (ArterialPET) scanner for standalone blood input function derivation
    Karakatsanis, Nicolas
    Fung, Edward
    Akerele, Mercy
    Pollenz, Louis
    Gross, Robert
    Sinelnikov, Yegor
    Mariner, Tom
    Alessi, Marc
    Babich, John
    Nehmeh, Sadek
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [34] Performance Evaluation of Quantitative SPECT/CT: Applying NEMA NU2 PET Measurements to SPECT
    Ryu, HyunJu
    Eslick, Enid
    Willowson, Kathy P.
    Meikle, Steven R.
    Bailey, Dale L.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [35] Performance Evaluation of Philips Forte Dual Head SPECT Using Nema NU1-2001 Standard
    Kim, J. H.
    Lee, J. S.
    Kim, J. S.
    Lee, B. I.
    Lee, D. S.
    Chung, J. K.
    Lee, M. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S259 - S259
  • [36] Performance evaluation of a high resolution BGO PET/CT using NEMA2001 standard
    Im, K. C.
    Ryu, J.
    Kim, J. S.
    Sheen, H. S.
    Lee, Y. H.
    Kim, E. N.
    Moon, D. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S340 - S340
  • [37] Image-Quality Assessment for Several Positron Emitters Using the NEMA NU 4-2008 Standards in the Siemens Inveon Small-Animal PET Scanner
    Disselhorst, Jonathan A.
    Brom, Maarten
    Laverman, Peter
    Slump, Cornelius H.
    Boerman, Otto C.
    Oyen, Wim J. G.
    Gotthardt, Martin
    Visser, Eric P.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (04) : 610 - 617
  • [39] Development and validation of NEMA NU-2 equivalent sensitivity and scatter phantoms for PET performance characteristic evaluation
    Sawant, Viraj
    Jha, Ashish Kumar
    Rawat, Bipin Singh
    Vishwakarma, R. S.
    Sahoo, Sridhar
    Selvam, T. Palani
    Rangarajan, Venkatesh
    HEALTH AND TECHNOLOGY, 2024, : 367 - 375
  • [40] Image quality as a function of reconstruction algorithms and their parameter settings for the Siemens Inveon small-animal PET scanner evaluated using the NEMA NU4 2008 standards
    Visser, E. P.
    Disselhorst, J. A.
    van Lier, M. G. J. T.
    Laverman, P.
    Gotthardt, M.
    Oyen, W. J. G.
    Boerman, O. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S171 - S171