Performance evaluation of siemens CTI ECAT EXACT 47 PET scanner using NEMA NU2-2001

被引:0
|
作者
Kim, JS [1 ]
Lee, JS [1 ]
Lee, DS [1 ]
Jung, JK [1 ]
Lee, MC [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul, South Korea
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner was measured using NEMA NU2-2001 standard. ECAT EXACT 47 is a BGO crystal based PET scanner. Coincidence window are set to 12 ns, and energy window are set to 250 similar to 650 keV. For the spatial resolution measurement, F-18 point source was placed at 1cm and 10 cm offset from the center of transaxial FOV. Images were reconstructed using FBP with ramp filter. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by 1 similar to 5 aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity were estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 solution (2D: 2,900 MBq), and coincidence count rates were measured for 7 half-lives to obtain noise equivalent count rate (NECR) and scatter fraction. Transverse and axial resolutions at 1cm offset from the center were 9.1 and 9.8 mm (FBP, 2D and 3D), Sensitivity values were 709 (2D), 3332 (3D) cps/MBq at the center and 796(2D), 4050 (3D) cps/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D). Peak true count rate and NECR were 64.0 kcps@37.5 kBq/mL and 49.6 kcps@37.5 kBq/mL in 2D. Information about the performance of EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.
引用
收藏
页码:3118 / 3120
页数:3
相关论文
共 50 条
  • [41] Performance measurements for the PET/CT Discovery-600 using NEMA NU 2-2007 standards
    De Ponti, E.
    Morzenti, S.
    Guerra, L.
    Pasquali, C.
    Arosio, M.
    Bettinardi, V.
    Crespi, A.
    Gilardi, M. C.
    Messa, C.
    MEDICAL PHYSICS, 2011, 38 (02) : 968 - 974
  • [42] PERFORMANCE EVALUATION OF PRECLINICAL PET SCANNERS WITH THE NEMA NU-4 IMAGE QUALITY PHANTOM USING A COLLECTION OF RADIOISOTOPES
    Nezich, Rik
    Reilhac, Anthonin
    Zahra, David
    Price, Roger
    INTERNAL MEDICINE JOURNAL, 2013, 43 : 23 - 23
  • [43] Performance Evaluation of the uEXPLORER Total-Body PET/CT Scanner Based on NEMA NU 2-2018 with Additional Tests to Characterize PET Scanners with a Long Axial Field of View
    Spencer, Benjamin A.
    Berg, Eric
    Schmall, Jeffrey P.
    Omidvari, Negar
    Leung, Edwin K.
    Abdelhafez, Yasser G.
    Tang, Songsong
    Deng, Zilin
    Dong, Yun
    Lv, Yang
    Bao, Jun
    Liu, Weiping
    Li, Hongdi
    Jones, Terry
    Badawi, Ramsey D.
    Cherry, Simon R.
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (06) : 861 - 870
  • [44] PET performance measurements for an LSO-based combined PET/CT scanner using the National Electrical Manufacturers Association NU 2-2001 standard
    Erdi, YE
    Nehmeh, SA
    Mulnix, T
    Humm, JL
    Watson, CC
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (05) : 813 - 821
  • [45] NEMA NU2-like performance evaluation of a helmet-type brain TOF-PET prototype
    Akamatsu, Go
    Yoshida, Eiji
    Tashima, Hideaki
    Iwao, Yuma
    Takahashi, Miwako
    Yamashita, Taichi
    Yamaya, Taiga
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [46] Characterization and optimization of image quality as a function of reconstruction algorithms and parameter settings in a Siemens Inveon small-animal PET scanner using the NEMA NU 4-2008 standards
    Visser, Eric P.
    Disselhorst, Jonathan A.
    van Lier, Monique G. J. T. B.
    Laverman, Peter
    de Jong, Gabie M.
    Oyen, Wim J. G.
    Boerman, Otto C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 357 - 367
  • [47] Performance evaluation of the Biograph mCT Flow PET/CT system according to the NEMA NU2-2012 standard
    Rausch I.
    Cal-González J.
    Dapra D.
    Gallowitsch H.J.
    Lind P.
    Beyer T.
    Minear G.
    EJNMMI Physics, 2 (1) : 1 - 17
  • [48] Performance Evaluation of the New Discovery IQ Five Rings PET/CT Scanner According to NEMA NU-2 Standard and the Image Quality Test with Low Activity Protocols
    Reynes-Llompart, G.
    Montes, E.
    Saldana, P.
    Romero-Zayas, I.
    Rustarazo-Losada, S.
    Mateo-Navarro, D.
    Picon, C.
    Gamez-Cenzano, C.
    Marti-Climent, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S523 - S523
  • [49] NEMA NU 2-2007 Performance Characteristics of GE Signa Integrated PET/MR: Impact of Using Different PET Isotopes
    Caribe, P.
    Koole, M.
    Vandenberghe, S.
    Deller, T.
    van Laere, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S339 - S339
  • [50] Comparative evaluation of two commercial PET scanners, ECAT EXACT HR+ and Biograph 2, using GATE
    Karakatsanis, N.
    Sakellios, N.
    Tsantilas, N. X.
    Dikaios, N.
    Tsoumpas, C.
    Lazaro, D.
    Loudos, G.
    Schmidtlein, C. R.
    Louizi, K.
    Valais, J.
    Nikolopoulos, D.
    Malamitsi, J.
    Kandarakis, J.
    Nikita, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 368 - 372