Comparative evaluation of two commercial PET scanners, ECAT EXACT HR+ and Biograph 2, using GATE

被引:40
|
作者
Karakatsanis, N.
Sakellios, N.
Tsantilas, N. X.
Dikaios, N.
Tsoumpas, C.
Lazaro, D.
Loudos, G.
Schmidtlein, C. R.
Louizi, K.
Valais, J.
Nikolopoulos, D.
Malamitsi, J.
Kandarakis, J.
Nikita, K.
机构
[1] Natl Tech Univ Athens, Nucl Imaging Med Lab, Biomed Simulat & Imaging Appl Lab, Sch Elect & Comp Engn, GR-15780 Athens, Greece
[2] Univ Athens, GR-11527 Athens, Greece
[3] Technol Educ Inst Athens, GR-12210 Athens, Greece
[4] Hammersmith Hosp, Hammersmith Imanet Ltd, London W12 0NN, England
[5] CHU Pitie Salpetriere, UMR 678 INSERM UPMC, F-75634 Paris 13, France
[6] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
GATE; PET; HR; biograph; Monte Carlo simulations; validation;
D O I
10.1016/j.nima.2006.08.110
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Geant4 application for tomographic emission (GATE) is a generic Monte Carlo simulation platform based on a general-purpose code GEANT4 and designed to simulate positron emission tomography (PET) and single photon emission tomography systems. Monte Carlo simulations are used in nuclear medicine to model imaging systems and develop and assess tomographic reconstruction algorithms and correction methods for improved image quantification. The purpose of this study is to validate two GATE models of the commercial available PET scanner HR+ and the PET/CT Biograph 2. The geometry of the system components has been described in GATE, including detector ring, crystal blocks, PMTS etc. The energy and spatial resolution of the scanners as given by the manufacturers have been taken into account. The GATE simulated results are compared directly to experimental data obtained using a number of NEMA NU-2-2001 performance protocols, including spatial resolution, sensitivity and scatter fraction. All the respective phantoms are precisely modeled. Furthermore, an approximate dead-time model both at the level of single and coincidence events was developed so that the simulated count rate curve can satisfactorily match the experimental count rate performance curve for each scanner In addition a software tool was developed to build the sinograms from the simulated data and import them into the software for tomographic image reconstruction where the reconstruction algorithm of FBP3DRP was applied. An agreement of less than 0.8 mm was obtained between the spatial resolution of the simulated system and the experimental results. Also the simulated scatter fraction for the NEMA NU 2-2001 scatter phantom matched the experimental results to within 3% of measured values. Finally the ratio of the simulated sensitivities with sources radially offset 0 and 10 cm from the central axis of each of the two scanners reaches an agreement of less than 1 % between the simulated and experimental values. This simulation code will be used in a second phase in order to study scatter phenomena and motion artifacts. The simulation results will be used to optimize image reconstruction algorithms, with emphasis on dynamic PET studies. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:368 / 372
页数:5
相关论文
共 46 条
  • [1] Performance of list mode data acquisition with ECAT EXACT HR and ECAT EXACT HR+ positron emission scanners
    Watabe, H
    Matsumoto, K
    Senda, M
    Iida, H
    [J]. ANNALS OF NUCLEAR MEDICINE, 2006, 20 (03) : 189 - 194
  • [2] Performance of list mode data acquisition with ECAT EXACT HR and ECAT EXACT HR+ positron emission scanners
    Hiroshi Watabe
    Keüchi Matsumoto
    Michio Senda
    Hidehiro Iida
    [J]. Annals of Nuclear Medicine, 2006, 20 : 189 - 194
  • [3] Monte Carlo simulation for the ECAT EXACT HR+ system using GATE
    Jan, S
    Comtat, C
    Strul, D
    Santin, G
    Trébossen, R
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2545 - 2548
  • [4] BIOGRAPH 64型PET/CT与ECAT EXACT HR+型PET的性能比较
    程午樱
    朱朝晖
    欧阳萌
    霍力
    [J]. 现代仪器与医疗, 2008, (04) : 32 - 34
  • [5] Performance evaluation of the whole-body PET scanner ECAT EXACT HR+
    Adam, LE
    Zaers, J
    Ostertag, H
    Trojan, H
    Bellemann, ME
    Brix, G
    Lorenz, WJ
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1270 - 1274
  • [6] NEMA evaluation of the first and second generation of the Ecat Exact and Ecat Exact HR family of scanners.
    Eriksson, L
    Wienhard, K
    Eriksson, M
    Casey, ME
    Knoess, C
    Bruckbauer, T
    Hamill, J
    Mulnix, T
    Vollmar, S
    Bendriem, B
    Heiss, WD
    Nutt, R
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1223 - 1226
  • [7] A Monte Carlo Study of Clinical PET ECAT EXACT HR plus Using GATE
    Saaidi, Rahal
    Toufique, Yassine
    Merouani, Asad
    Elbouhali, Othman
    El Moursli, Rajaa Cherkaoui
    [J]. BASIC CONCEPTS IN NUCLEAR PHYSICS: THEORY, EXPERIMENTS AND APPLICATIONS, 2016, 182 : 223 - 225
  • [8] NEMA count-rate evaluation of the first and second generation of the Ecat Exact and Ecat Exact HR family of scanners
    Eriksson, L
    Wienhard, K
    Eriksson, M
    Casey, ME
    Knoess, C
    Bruckbauer, T
    Hamill, J
    Mulnix, T
    Vollmar, S
    Bendriem, B
    Heiss, WD
    Nutt, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 640 - 643
  • [9] Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard
    Adam, LE
    Zaers, J
    Ostertag, H
    Trojan, H
    Bellemann, ME
    Brix, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1172 - 1179
  • [10] Quantitative imaging of yttrium-86 PET with the ECAT EXACT HR+ in 2D mode
    Kull, T
    Ruckgaber, J
    Weller, R
    Reske, S
    Glatting, G
    [J]. CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2004, 19 (04) : 482 - 490