Effects of Motion Artifact on the Blood Oxygen Saturation Estimate in Pulse Oximetry

被引:0
|
作者
Clarke, Geoffrey W. J. [1 ]
Chan, Adrian D. C. [1 ]
Adler, Andy [1 ]
机构
[1] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON K1S 5B6, Canada
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Oxygen saturation estimates from pulse oximeters (SpO(2)) have been shown to be unreliable in the presence of motion artifact. This may cause errors in the clinical environment if the device falsely detects normal or desaturated conditions. This paper seeks to investigate the failure modes of the standard SpO(2) calculation algorithm in the presence of motion artifact. A Texas Instruments AFE4400 evaluation module was used to collect data. The board is designed for pulse oximetry applications and allows access to the raw photoplethysmograph signals. Measurements were taken from a single subject with a finger probe. Signals were collected both while moving the instrumented hand and while moving the sensor without moving the hand. These were compared to a control signal where the subject remained motionless. Oxygen saturation was constant as verified by a Clevemed Bioradio SpO(2) probe on the subject's other hand, which remained motionless for all of the measurements. The results showed a significant decrease of measured SpO(2) during motion of the hand but not during motion of the sensor. This was likely due to the probe detecting the movement of venous blood, or failure to correctly detect peaks in the PPG signals. The variability of the measured SpO(2) increased during motion of the hand and motion of the sensor, likely due to variation of the optical path length through the tissue. This work will help future development of algorithms to improve the performance of pulse oximetry in ambulatory conditions.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 50 条
  • [21] Maternal position during labor: Effects on fetal oxygen saturation measured by pulse oximetry
    Carbonne, B
    Benachi, A
    Leveque, ML
    Cabrol, D
    Papiernik, E
    OBSTETRICS AND GYNECOLOGY, 1996, 88 (05): : 797 - 800
  • [22] Effect of exchange blood transfusion on oxygen saturation of neonates with severe neonatal jaundice by pulse oximetry
    Shakur, Abubakar Muhammed
    Garba, Nuhu Abubakar
    Ahmadu, Ibrahim
    Apollos, Daniel
    Wada, Aminu
    Abdullahil, Safiya Garba
    Mohammed, Abdulsalam
    Asani, Mustafa O.
    Aliyu, Ibrahim
    JOURNAL OF ACUTE DISEASE, 2021, 10 (03) : 112 - 116
  • [23] PREDICTING CHANGES IN OXYGEN-SATURATION USING PULSE OXIMETRY
    SAPSFORD, DJ
    JONES, JG
    BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (04) : P497 - P497
  • [24] Reflectance Pulse Oximetry for Blood Oxygen Saturation Measurement from Diverse Locations - A Preliminary Analysis
    Kiruthiga, A.
    Alex, Annamol
    Balamugesh, T.
    Prabhu, Dinesh R.
    Christopher, D. J.
    Preejith, S. P.
    Joseph, Jayaraj
    Sivaprakasam, Mohanasankar
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 666 - 671
  • [25] FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY
    BUSCHMANN, J
    RALL, G
    KNITZA, R
    LANCET, 1992, 339 (8793): : 615 - 615
  • [26] TIME TO EQUILIBRATION OF OXYGEN-SATURATION USING PULSE OXIMETRY
    GRUBER, P
    KWIATKOWSKI, T
    SILVERMAN, R
    FLASTER, E
    AUERBACH, C
    ACADEMIC EMERGENCY MEDICINE, 1995, 2 (09) : 810 - 815
  • [27] BIOLOGICAL QUALITY CONTROL FOR PULSE OXIMETRY OXYGEN SATURATION MEASUREMENT
    Back, Geraldine M.
    Dooney, Natalie A.
    Robiony-Rogers, David
    RESPIROLOGY, 2012, 17 : 7 - 7
  • [28] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293
  • [29] CONTINUOUS MONITORING OF FETAL OXYGEN-SATURATION BY PULSE OXIMETRY
    LUTTKUS, A
    FENGLER, TW
    FRIEDMANN, W
    DUDENHAUSEN, JW
    OBSTETRICS AND GYNECOLOGY, 1995, 85 (02): : 183 - 186
  • [30] Methodology of generating motion artifact affects measures of pulse oximetry experimental performance
    Jopling, MW
    Bebout, DE
    Mannheimer, P
    CRITICAL CARE MEDICINE, 2000, 28 (12) : A61 - A61