Effects of Motion Artifact on the Blood Oxygen Saturation Estimate in Pulse Oximetry

被引:0
|
作者
Clarke, Geoffrey W. J. [1 ]
Chan, Adrian D. C. [1 ]
Adler, Andy [1 ]
机构
[1] Carleton Univ, Dept Syst & Comp Engn, Ottawa, ON K1S 5B6, Canada
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Oxygen saturation estimates from pulse oximeters (SpO(2)) have been shown to be unreliable in the presence of motion artifact. This may cause errors in the clinical environment if the device falsely detects normal or desaturated conditions. This paper seeks to investigate the failure modes of the standard SpO(2) calculation algorithm in the presence of motion artifact. A Texas Instruments AFE4400 evaluation module was used to collect data. The board is designed for pulse oximetry applications and allows access to the raw photoplethysmograph signals. Measurements were taken from a single subject with a finger probe. Signals were collected both while moving the instrumented hand and while moving the sensor without moving the hand. These were compared to a control signal where the subject remained motionless. Oxygen saturation was constant as verified by a Clevemed Bioradio SpO(2) probe on the subject's other hand, which remained motionless for all of the measurements. The results showed a significant decrease of measured SpO(2) during motion of the hand but not during motion of the sensor. This was likely due to the probe detecting the movement of venous blood, or failure to correctly detect peaks in the PPG signals. The variability of the measured SpO(2) increased during motion of the hand and motion of the sensor, likely due to variation of the optical path length through the tissue. This work will help future development of algorithms to improve the performance of pulse oximetry in ambulatory conditions.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 50 条
  • [41] Pulse Oximetry and Arterial Oxygen Saturation during Cardiopulmonary Exercise Testing
    Ascha, Mona
    Bhattacharyya, Anirban
    Ramos, Jose A.
    Tonelli, Adriano R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (10): : 1992 - 1997
  • [42] THE EFFECT OF CARBOXYHEMOGLOBIN ON PULSE-OXIMETRY OXYGEN-SATURATION MEASUREMENTS
    PANACEK, EA
    JOURILLES, NJ
    SHERMAN, BW
    RUTHERFORD, WF
    CLINICAL RESEARCH, 1991, 39 (02): : A421 - A421
  • [43] Effects of maternal oxygen administration on fetal pulse oximetry measured by fetal pulse oximetry
    Haydon, Michael L.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 196 (04)
  • [44] Discrepancies between Arterial Oxygen Saturation and Functional Oxygen Saturation Measured with Pulse Oximetry in Very Preterm Infants
    Rosychuk, Rhonda J.
    Hudson-Mason, Ann
    Eklund, Dianne
    Lacaze-Masmonteil, Thierry
    NEONATOLOGY, 2012, 101 (01) : 14 - 19
  • [45] Comparison of oxygen saturation by pulse oximetry and co-oximetry during exercise testing in patients with COPD
    McGovern, JP
    Sasse, SA
    Stansbury, DW
    Causing, LA
    Light, RW
    CHEST, 1996, 109 (05) : 1151 - 1155
  • [46] Correlation and concordance of arterial oxygen saturation measured by arterial blood gases and pulse oximetry according to anatomical location
    Correa, Cristhian
    Gallo Gonzalez, Virginia
    Moreno-Tome, Rosa Maria Rojas
    Suarez Rubio, Maria Del Carmen
    Pesquera Criado, Rafael
    Lopez Padilla, Daniel
    Antonella Benedetti, Paola
    Garcia Lopez, Jose Javier
    Puente Maestu, Luis
    EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [47] Reduction of motion artifact in pulse oximetry by smoothed pseudo Wigner-Ville distribution
    Yan Y.-S.
    Poon C.C.Y.
    Zhang Y.-T.
    Journal of NeuroEngineering and Rehabilitation, 2 (1)
  • [48] Study On Resistance to Motion Artifact in Pulse Oximetry Measurement Using Segment Filter Method
    Li Qing-bo
    Nie Xin
    Zhang Guang-jun
    Wu Jin-guang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (11) : 2994 - 2997
  • [49] Comparative Analysis of Oxygen Saturation by Pulse Oximetry and Arterial Blood Gas in Hypoxemic Patients in a Tertiary Care Hospital
    Abraham, Elen A.
    Verma, Ghanshyam
    Arafat, Yasar
    Acharya, Sourya
    Kumar, Sunil
    Pantbalekundri, Nikhil
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (07)
  • [50] A Comparison of Oxygen Saturation in White-tailed Deer Estimated by Pulse Oximetry and from Arterial Blood Gases
    Muller, Lisa I.
    Osborn, David A.
    Doherty, Tom
    Keel, M. Kevin
    Miller, Brad F.
    Warren, Robert J.
    Miller, Karl V.
    JOURNAL OF WILDLIFE DISEASES, 2012, 48 (02) : 458 - 461