Clinical Evaluation of MR-Gated Respiratory Motion Correction in Simultaneous PET/MRI

被引:1
|
作者
Li, Hui [1 ]
Meng, Xiangxi [1 ]
Guan, Xiangping [1 ]
Zhou, Nina [1 ]
Liu, Hui [2 ]
Zhang, Yan [1 ]
Yu, Boqi [1 ]
Zhu, Hua [1 ]
Li, Nan [1 ]
Yang, Zhi [1 ]
机构
[1] Peking Univ Canc Hosp & Inst, Key Lab Carcinogenesis & Translat Res, Minist Educ Beijing, Dept Nucl Med, 52 Fucheng Rd, Beijing 100142, Peoples R China
[2] United Imaging Healthcare, Shanghai, Peoples R China
关键词
PET; MRI; motion correction; lesion detection; lesion quantification; CARDIAC MOTION; PET;
D O I
10.1097/RLU.0000000000003510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The recently available gated T1-weighted imaging with the Dixon technique enables the synchronized gating signal for both MR acquisition and PET reconstruction. Herein, we evaluated the clinical value of this MR-gated PET reconstruction in the thoracic-abdominal PET/MRI compared with non-MR-gated method. Methods Twenty patients (28 hypermetabolic target lesions) underwent PET/MRI. Four types of PET images were reconstructed: non-MR-gating + gated attenuation correction (AC) (group A), MR-gating + gated AC (group B), non-MR-gating + breath-hold (BH) AC (group C), and MR-gating + BH AC (group D). A 4-point objective scale (from well match to obvious mismatch was scored from 3 to 0) was proposed to evaluate the mismatch. The detection rate and quantitative metrics were also evaluated. Results In the patient-based analysis, for groups A through D, the detection rates were 90%, 100%, 85%, and 90% as well as 95%, 100%, 85%, and 85%, assessed by readers 1 and 2, respectively, and significant difference of mismatch score was observed with the highest proportion of 3 points in group B (85%, 90%, 35%, and 40%, and 80%, 90%, 35%, and 20%, assessed by readers 1 and 2, respectively). The lesion-based analysis demonstrated significant differences in quantitative metrics for groups A through D (all P's < 0.05), with the highest quantitative metrics in group B (SUVmax: 7.49 +/- 3.37, 8.45 +/- 3.82, 6.90 +/- 3.24, and 7.69 +/- 3.50; SUVmean: 3.90 +/- 1.60, 4.34 +/- 1.84, 3.67 +/- 1.61, and 4.03 +/- 1.81; SUVpeak: 5.60 +/- 2.50, 6.10 +/- 2.80, 5.22 +/- 2.40, and 5.65 +/- 2.68; signal-to-noise ratio: 136.06 +/- 90.58, 136.24 +/- 81.63, 99.52 +/- 53.16, and 107.57 +/- 69.05). Conclusions The MR-gated reconstruction using gated AC reduced the mismatch between MR and PET images and improved the thoracic-abdominal PET image quality in simultaneous PET/MRI systems.
引用
下载
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [41] Hybrid MR-guided and PET-guided motion correction of PET images in simultaneous PET/MR
    Feng, Tao
    Ahlman, Mark
    Tsui, Benjamin
    Guo, Liheng
    Guttman, Mike
    McVeigh, Elliot
    Bluemke, David
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [42] Quantitative evaluation of PET respiratory motion correction using real- time PET/MR simulated data
    Irene Polycarpou
    Charalampos Tsoumpas
    Andrew King
    Paul K Marsden
    EJNMMI Physics, 1 (Suppl 1)
  • [43] In-vivo studies of tagged MR based PET motion correction in simultaneous PET-MR
    Chun, Se Young
    Moussallem, Elie
    Reese, Timothy
    Guerin, Bastien
    Catana, Ciprian
    Alpert, Nathaniel
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [44] Pulmonary imaging using respiratory motion compensated simultaneous PET/MR
    Dutta, Joyita
    Huang, Chuan
    Li, Quanzheng
    El Fakhri, Georges
    MEDICAL PHYSICS, 2015, 42 (07) : 4227 - 4240
  • [45] Creation of a generic respiratory motion model for motion correction in PET/MRI imaging
    Fayad, Hadi
    Buerger, Christian
    Tsoumpas, Charalampos
    Cheze-Le Rest, Catherine
    Visvikis, Dimitris
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [46] Respiratory motion compensation for simultaneous PET/MR based on highly undersampled MR data
    Rank, Christopher M.
    Heusser, Thorsten
    Wetscherek, Andreas
    Freitag, Martin T.
    Sedlaczek, Oliver
    Schlemmer, Heinz-Peter
    Kachelriess, Marc
    MEDICAL PHYSICS, 2016, 43 (12) : 6234 - 6245
  • [47] Motion estimation and correction for simultaneous PET/MR using SIRF and CIL
    Brown, Richard
    Kolbitsch, Christoph
    Delplancke, Claire
    Papoutsellis, Evangelos
    Mayer, Johannes
    Ovtchinnikov, Evgueni
    Pasca, Edoardo
    Neji, Radhouene
    Costa-luis, Casper da
    Gillman, Ashley G.
    Ehrhardt, Matthias J.
    McClelland, Jamie R.
    Eiben, Bjoern
    Thielemans, Kris
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2021, 379 (2204):
  • [48] Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling
    Robson, Philip M.
    Trivieri, MariaGiovanna
    Karakatsanis, Nicolas A.
    Padilla, Maria
    Abgral, Ronan
    Dweck, Marc R.
    Kovacic, Jason C.
    Fayad, Zahi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (22):
  • [49] Using ITK to obtain motion transform in anatomically guided PET motion correction for simultaneous PET/MR
    Cheng, Ju-Chieh
    Laforest, Richard
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [50] Evaluation of Two PET Motion Correction Techniques For Simultaneous Real-Time PET-MR Acquisitions Using An MR-Derived Motion Model
    Tsoumpas, Charalampos
    Agarwal, Siddharth
    Marsden, Paul K.
    King, Andrew P.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2519 - 2522