Respiratory motion compensation for simultaneous PET/MR based on highly undersampled MR data

被引:24
|
作者
Rank, Christopher M. [1 ]
Heusser, Thorsten [1 ]
Wetscherek, Andreas [1 ,2 ,3 ]
Freitag, Martin T. [4 ]
Sedlaczek, Oliver [4 ]
Schlemmer, Heinz-Peter [4 ]
Kachelriess, Marc [1 ]
机构
[1] German Canc Res Ctr, Med Phys Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[2] Inst Canc Res, Joint Dept Phys, 123 Old Brompton Rd, London SW7 3RP, England
[3] Royal Marsden NHS Fdn Trust, 123 Old Brompton Rd, London SW7 3RP, England
[4] German Canc Res Ctr, Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
关键词
PET/MR; motion compensation; respiratory motion; radial acquisition; high undersampling; POSITRON-EMISSION-TOMOGRAPHY; IMAGE-RECONSTRUCTION; LUNG-CANCER; ONCOLOGY APPLICATIONS; SCANNER; MODEL; CT; ATTENUATION; THERAPY;
D O I
10.1118/1.4966128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Positron emission tomography (PET) of the thorax region is impaired by respiratory patient motion. To account for motion, the authors propose a new method for PET/magnetic resonance (MR) respiratory motion compensation (MoCo), which uses highly undersampled MR data with acquisition times as short as 1 min/bed. Methods: The proposed PET/MR MoCo method (4D jMoCo PET) uses radial MR data to estimate the respiratory patient motion employing MR joint motion estimation and image reconstruction with temporal median filtering. Resulting motion vector fields are incorporated into the system matrix of the PET reconstruction. The proposed approach is evaluated for the thorax region utilizing a PET/MR simulation with 1 min MR acquisition time and simultaneous PET/MR measurements of six patients with MR acquisition times of 1 and 5 min and radial undersampling factors of 11.2 and 2.2, respectively. Reconstruction results are compared to 3D PET, 4D gated PET and a standard MoCo method (4D sMoCo PET), which performs iterative image reconstruction and motion estimation sequentially. Quantitative analysis comprises the parameters SUVmean, SUVmax, full width at half-maximum/lesion volume, contrast and signal-to-noise ratio. Results: For simulated PET data, our quantitative analysis shows that the proposed 4D jMoCo PET approach with temporal filtering achieves the best quantification accuracy of all tested reconstruction methods with a mean absolute deviation of 2.3% when compared to the ground truth. For measured PET patient data, the mean absolute deviation of 4D jMoCo PET using a 1 min MR acquisition for motion estimation is 2.1% relative to the 5 min MR acquisition. This demonstrates a robust behavior even in case of strong undersampling at MR acquisition times as short as 1 min. In contrast, 4D sMoCo PET shows considerable reduction of quantification accuracy for the 1 min MR acquisition time. Relative to 3D PET, the proposed 4D jMoCo PET approach with temporal filtering yields an average increase of SUVmean, SUVmax, and contrast of 29.9% and 13.8% for simulated and measured PET data, respectively. Conclusions: Employing artifact-robust motion estimation enables PET/MR respiratory MoCo with MR acquisition times as short as 1 min/bed improving PET image quality and quantification accuracy. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:6234 / 6245
页数:12
相关论文
共 50 条
  • [1] Respiratory Motion Compensation for Simultaneous PET/MR based on strongly undersampled radial MR data
    Christopher M Rank
    Thorsten Heußer
    Andreas Wetscherek
    Marc Kachelrieß
    [J]. EJNMMI Physics, 2 (Suppl 1)
  • [2] Artifact Model-Based Respiratory Motion Compensation (MoCo) for Simultaneous PET/MR Based on Strongly Undersampled Radial MR Data
    Rank, Christopher M.
    Heusser, Thorsten
    Brehm, Marcus
    Kachelriess, Marc
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [3] Respiratory motion compensation for simultaneous PET/MR based on a 3D-2D registration of strongly undersampled radial MR data - a simulation study
    Rank, Christopher M.
    Heusser, Thorsten
    Flach, Barbara
    Brehm, Marcus
    Kachelriess, Mare
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [4] MR-based motion compensation in simultaneous cardiac PET-MR
    Petibon, Yoann
    Ouyang, Jinsong
    Zhu, Xuping
    Reese, Timothy
    Dagher, Joseph
    Catana, Ciprian
    El Fakhri, Georges
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [5] Dynamic MR-based Respiratory Motion Compensation for Hybrid PET/MR System
    Miao, Shun
    Liao, Rui
    Moran, Gerald
    Butler, John
    Pan, Li
    Wang, Z. Jane
    [J]. PROCEEDINGS OF THE 2014 9TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2014, : 1915 - +
  • [6] Five-Dimensional Respiratory and Cardiac Motion Compensation for Simultaneous PET/MR
    Rank, Christopher M.
    Heusser, Thorsten
    Wetscherek, Andreas
    Freitag, Martin T.
    Schlemmer, Heinz-Peter
    Kachelriess, Marc
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [7] RESPIRATORY MOTION COMPENSATION IN SIMULTANEOUS PET/MR USING A MAXIMUM A POSTERIORI APPROACH
    Dutta, Joyita
    El Fakhri, Georges
    Huang, Chuan
    Petibon, Yoann
    Reese, Timothy G.
    Li, Quanzheng
    [J]. 2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 800 - 803
  • [8] MR-Based Cardiac and Respiratory Motion-Compensation Techniques for PET-MR Imaging
    Munoz, Camila
    Kolbitsch, Christoph
    Reader, Andrew J.
    Marsden, Paul
    Schaeffter, Tobias
    Prieto, Claudia
    [J]. PET CLINICS, 2016, 11 (02) : 179 - 191
  • [9] MR Image-based PET Respiratory Motion Correction in PET/MR
    Manber, Richard
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    Ourselin, Sebastien
    Arridge, Simon
    Wan, Ming Young Simon
    O'Meara, Celia
    Atkinson, David
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [10] Respiratory Motion Compensation in PET/MR: Evaluation of an Integrated Approach
    Schneider, Manuel
    Zimmermann, Judith
    Schachoff, Sylvia
    Winter, Anna
    Fenchel, Matthias
    Grimm, Robert
    Hong, Inki
    Casey, Michael
    Farst, Sebastian
    Hemmert, Werner
    Haase, Axel
    Schwaiger, Markus
    Nekolla, Stephan
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57