Clinical Evaluation of MR-Gated Respiratory Motion Correction in Simultaneous PET/MRI

被引:1
|
作者
Li, Hui [1 ]
Meng, Xiangxi [1 ]
Guan, Xiangping [1 ]
Zhou, Nina [1 ]
Liu, Hui [2 ]
Zhang, Yan [1 ]
Yu, Boqi [1 ]
Zhu, Hua [1 ]
Li, Nan [1 ]
Yang, Zhi [1 ]
机构
[1] Peking Univ Canc Hosp & Inst, Key Lab Carcinogenesis & Translat Res, Minist Educ Beijing, Dept Nucl Med, 52 Fucheng Rd, Beijing 100142, Peoples R China
[2] United Imaging Healthcare, Shanghai, Peoples R China
关键词
PET; MRI; motion correction; lesion detection; lesion quantification; CARDIAC MOTION; PET;
D O I
10.1097/RLU.0000000000003510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The recently available gated T1-weighted imaging with the Dixon technique enables the synchronized gating signal for both MR acquisition and PET reconstruction. Herein, we evaluated the clinical value of this MR-gated PET reconstruction in the thoracic-abdominal PET/MRI compared with non-MR-gated method. Methods Twenty patients (28 hypermetabolic target lesions) underwent PET/MRI. Four types of PET images were reconstructed: non-MR-gating + gated attenuation correction (AC) (group A), MR-gating + gated AC (group B), non-MR-gating + breath-hold (BH) AC (group C), and MR-gating + BH AC (group D). A 4-point objective scale (from well match to obvious mismatch was scored from 3 to 0) was proposed to evaluate the mismatch. The detection rate and quantitative metrics were also evaluated. Results In the patient-based analysis, for groups A through D, the detection rates were 90%, 100%, 85%, and 90% as well as 95%, 100%, 85%, and 85%, assessed by readers 1 and 2, respectively, and significant difference of mismatch score was observed with the highest proportion of 3 points in group B (85%, 90%, 35%, and 40%, and 80%, 90%, 35%, and 20%, assessed by readers 1 and 2, respectively). The lesion-based analysis demonstrated significant differences in quantitative metrics for groups A through D (all P's < 0.05), with the highest quantitative metrics in group B (SUVmax: 7.49 +/- 3.37, 8.45 +/- 3.82, 6.90 +/- 3.24, and 7.69 +/- 3.50; SUVmean: 3.90 +/- 1.60, 4.34 +/- 1.84, 3.67 +/- 1.61, and 4.03 +/- 1.81; SUVpeak: 5.60 +/- 2.50, 6.10 +/- 2.80, 5.22 +/- 2.40, and 5.65 +/- 2.68; signal-to-noise ratio: 136.06 +/- 90.58, 136.24 +/- 81.63, 99.52 +/- 53.16, and 107.57 +/- 69.05). Conclusions The MR-gated reconstruction using gated AC reduced the mismatch between MR and PET images and improved the thoracic-abdominal PET image quality in simultaneous PET/MRI systems.
引用
下载
收藏
页码:297 / 302
页数:6
相关论文
共 50 条
  • [21] Performance improvement with respiratory gated PET using simultaneous PET-MRI
    Trott, Cathryn
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [22] Real-Time Respiratory Motion Correction for Simultaneous PET-MR Using an MR-Derived Motion Model
    King, A. P.
    Tsoumpas, C.
    Buerger, C.
    Schulz, V.
    Marsden, P.
    Schaeffter, T.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3589 - 3594
  • [23] Impact of MR-based head motion correction on amyloid PET diagnosis - A simultaneous PET/MRI study
    Schuerer, M.
    Jochimsen, T.
    Rullmann, M.
    Patt, M.
    Tiepolt, S.
    Schroeter, M.
    Weise, C.
    Saur, D.
    Hoffmann, K.
    Sabri, O.
    Barthel, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S410 - S411
  • [24] Respiratory motion correction in cardiac PET-MR by optical monitoring and incorporation of MRI data
    Boutchko, Rostyslav
    Saloner, David
    Gullberg, Grant
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [25] Respiratory Motion Correction of PET using Motion Parameters from MR
    Dikaios, Nikolaos
    Fryer, Tim D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2806 - 2808
  • [26] Self-gated MRI motion modeling for respiratory motion compensation in integrated PET/MRI
    Grimm, Robert
    Fuerst, Sebastian
    Souvatzoglou, Michael
    Forman, Christoph
    Hutter, Jana
    Dregely, Isabel
    Ziegler, Sibylle I.
    Kiefer, Berthold
    Hornegger, Joachim
    Block, Kai Tobias
    Nekolla, Stephan G.
    MEDICAL IMAGE ANALYSIS, 2015, 19 (01) : 110 - 120
  • [27] Quantitative Evaluation of PET Respiratory Motion Correction Using MR Derived Simulated Data
    Polycarpou, Irene
    Tsoumpas, Charalampos
    King, Andrew P.
    Marsden, Paul K.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (06) : 3110 - 3116
  • [28] MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
    Chun, Se Young
    Reese, Timothy G.
    Ouyang, Jinsong
    Guerin, Bastien
    Catana, Ciprian
    Zhu, Xuping
    Alpert, Nathaniel M.
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1284 - 1291
  • [29] PET motion correction using simultaneous PET-MR acquisition and MR-derived motion fields
    Tsoumpas, Charalampos
    Mackewn, Jane
    King, Andrew
    Buerger, Christian
    Totman, John
    Schaeffter, Tobias
    Marsden, Paul
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 : 532 - 532
  • [30] Evaluation of respiratory and cardiac motion correction schemes in dual gated PET/CT cardiac imaging
    Lamare, F.
    Le Maitre, A.
    Dawood, M.
    Schaefers, K. P.
    Fernandez, P.
    Rimoldi, O. E.
    Visvikis, D.
    MEDICAL PHYSICS, 2014, 41 (07)