Self-gated MRI motion modeling for respiratory motion compensation in integrated PET/MRI

被引:90
|
作者
Grimm, Robert [1 ,2 ]
Fuerst, Sebastian [3 ]
Souvatzoglou, Michael [3 ]
Forman, Christoph [1 ,2 ]
Hutter, Jana [1 ]
Dregely, Isabel [3 ]
Ziegler, Sibylle I. [3 ]
Kiefer, Berthold [2 ]
Hornegger, Joachim [1 ]
Block, Kai Tobias [4 ]
Nekolla, Stephan G. [3 ]
机构
[1] FAU Erlangen Nurnberg, Pattern Recognit Lab, Erlangen, Germany
[2] Siemens AG Healthcare MR, Erlangen, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Nucl Med, D-80290 Munich, Germany
[4] NYU, Dept Radiol, Langone Med Ctr, New York, NY 10016 USA
关键词
Respiratory motion; Motion compensation; PET/MRI; MRI; Respiratory gating; POSITRON-EMISSION-TOMOGRAPHY; ATTENUATION CORRECTION; TUMOR QUANTIFICATION; PET RECONSTRUCTION; HYBRID PET/MR; LUNG-TUMORS; SIMULATION; DELINEATION; ARTIFACTS; IMPACT;
D O I
10.1016/j.media.2014.08.003
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Accurate localization and uptake-quantification of lesions in the chest and abdomen using PET imaging is challenged by respiratory motion occurring during the exam. This work describes how a stack-of-stars MRI acquisition on integrated PET/MRI systems can be used to derive a high-resolution motion model, how many respiratory phases need to be differentiated, how much MRI scan time is required, and how the model is employed for motion-corrected PET reconstruction. MRI self-gating is applied to perform respiratory gating of the MRI data and simultaneously acquired PET raw data. After gated PET reconstruction, the MRI motion model is used to fuse the individual gates into a single, motion-compensated volume with high signal-to-noise ratio (SNR). The proposed method is evaluated in vivo for 15 clinical patients. The gating requires 5-7 bins to capture the motion to an average accuracy of 2 mm. With 5 bins, the motion-modeling scan can be shortened to 3-4 min. The motion-compensated reconstructions show significantly higher accuracy in lesion quantification in terms of standardized uptake value (SUV) and different measures of lesion contrast compared to ungated PET reconstruction. Furthermore, unlike gated reconstructions, the motion-compensated reconstruction does not lead to SNR loss. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 120
页数:11
相关论文
共 50 条
  • [1] Self-gated Radial MRI for Respiratory Motion Compensation on Hybrid PET/MR Systems
    Grimm, Robert
    Fuerst, Sebastian
    Dregely, Isabel
    Forman, Christoph
    Hutter, Jana Maria
    Ziegler, Sibylle I.
    Nekolla, Stephan
    Kiefer, Berthold
    Schwaiger, Markus
    Hornegger, Joachim
    Block, Tobias
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT III, 2013, 8151 : 17 - 24
  • [2] Self-Gated Respiratory Motion Rejection for Optoacoustic Tomography
    Ron, Avihai
    Davoudi, Neda
    Dean-Ben, Xose Luis
    Razansky, Daniel
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (13):
  • [3] Respiratory compensated PET with DOTATOC PET/MRI using motion registered and gated reconstruction
    Tao, Dora
    Pampaloni, Miguel Hernandez
    Ravanfar, Vahid
    Nakakura, Eric
    Bergsland, Emily
    Hope, Thomas
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [4] Self-gated cardiac cine MRI
    Larson, AC
    White, RD
    Laub, G
    McVeigh, ER
    Li, DB
    Simonetti, OP
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 93 - 102
  • [5] Respiratory Motion Resolved, Self-Gated 4D-MRI Using Rotating Cartesian K-Space Sampling
    Han, F.
    Zhou, Z.
    Yang, Y.
    Sheng, K.
    Hu, P.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3444 - 3444
  • [6] Clinical Evaluation of MR-Gated Respiratory Motion Correction in Simultaneous PET/MRI
    Li, Hui
    Meng, Xiangxi
    Guan, Xiangping
    Zhou, Nina
    Liu, Hui
    Zhang, Yan
    Yu, Boqi
    Zhu, Hua
    Li, Nan
    Yang, Zhi
    [J]. CLINICAL NUCLEAR MEDICINE, 2021, 46 (04) : 297 - 302
  • [7] Respiratory motion-resolved, self-gated 4D-MRI using rotating cartesian k-space (ROCK)
    Han, Fei
    Zhou, Ziwu
    Cao, Minsong
    Yang, Yingli
    Sheng, Ke
    Hu, Peng
    [J]. MEDICAL PHYSICS, 2017, 44 (04) : 1359 - 1368
  • [8] Cardiac and respiratory double self-gated cine MRI in the mouse at 7 T
    Hiba, B
    Richard, N
    Janier, M
    Croisille, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) : 506 - 513
  • [9] MRI for modeling of liver and skin respiratory motion
    Wong, KH
    VanMeter, JW
    Fricke, ST
    Maurer, CR
    Cleary, K
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 747 - 752
  • [10] Evaluation of a direct motion estimation/correction method in respiratory-gated PET/MRI with motion-adjusted attenuation
    Bousse, Alexandre
    Manber, Richard
    Holman, Beverley F.
    Atkinson, David
    Arridge, Simon
    Ourselin, Sebastien
    Hutton, Brian F.
    Thielemans, Kris
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2379 - 2390