Self-gated MRI motion modeling for respiratory motion compensation in integrated PET/MRI

被引:90
|
作者
Grimm, Robert [1 ,2 ]
Fuerst, Sebastian [3 ]
Souvatzoglou, Michael [3 ]
Forman, Christoph [1 ,2 ]
Hutter, Jana [1 ]
Dregely, Isabel [3 ]
Ziegler, Sibylle I. [3 ]
Kiefer, Berthold [2 ]
Hornegger, Joachim [1 ]
Block, Kai Tobias [4 ]
Nekolla, Stephan G. [3 ]
机构
[1] FAU Erlangen Nurnberg, Pattern Recognit Lab, Erlangen, Germany
[2] Siemens AG Healthcare MR, Erlangen, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Nucl Med, D-80290 Munich, Germany
[4] NYU, Dept Radiol, Langone Med Ctr, New York, NY 10016 USA
关键词
Respiratory motion; Motion compensation; PET/MRI; MRI; Respiratory gating; POSITRON-EMISSION-TOMOGRAPHY; ATTENUATION CORRECTION; TUMOR QUANTIFICATION; PET RECONSTRUCTION; HYBRID PET/MR; LUNG-TUMORS; SIMULATION; DELINEATION; ARTIFACTS; IMPACT;
D O I
10.1016/j.media.2014.08.003
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Accurate localization and uptake-quantification of lesions in the chest and abdomen using PET imaging is challenged by respiratory motion occurring during the exam. This work describes how a stack-of-stars MRI acquisition on integrated PET/MRI systems can be used to derive a high-resolution motion model, how many respiratory phases need to be differentiated, how much MRI scan time is required, and how the model is employed for motion-corrected PET reconstruction. MRI self-gating is applied to perform respiratory gating of the MRI data and simultaneously acquired PET raw data. After gated PET reconstruction, the MRI motion model is used to fuse the individual gates into a single, motion-compensated volume with high signal-to-noise ratio (SNR). The proposed method is evaluated in vivo for 15 clinical patients. The gating requires 5-7 bins to capture the motion to an average accuracy of 2 mm. With 5 bins, the motion-modeling scan can be shortened to 3-4 min. The motion-compensated reconstructions show significantly higher accuracy in lesion quantification in terms of standardized uptake value (SUV) and different measures of lesion contrast compared to ungated PET reconstruction. Furthermore, unlike gated reconstructions, the motion-compensated reconstruction does not lead to SNR loss. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 120
页数:11
相关论文
共 50 条
  • [21] Automatic compensation of motion artifacts in MRI
    Atkinson, D
    Hill, DLG
    Stoyle, PNR
    Summers, PE
    Clare, S
    Bowtell, R
    Keevil, SF
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (01) : 163 - 170
  • [22] Self-gated MRI of multiple beat morphologies in the presence of arrhythmias
    Contijoch, Francisco
    Iyer, Srikant Kamesh
    Pilla, James J.
    Yushkevich, Paul
    Gorman, Joseph H., III
    Gorman, Robert C.
    Litt, Harold
    Han, Yuchi
    Witschey, Walter R. T.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (02) : 678 - 688
  • [23] Markerless motion tracking and correction for PET, MRI, and simultaneous PET/MRI
    Slipsager, Jakob M.
    Ellegaard, Andreas H.
    Glimberg, Stefan L.
    Paulsen, Rasmus R.
    Tisdall, M. Dylan
    Wighton, Paul
    van der Kouwe, Andre
    Marner, Lisbeth
    Henriksen, Otto M.
    Law, Ian
    Olesen, Oline V.
    [J]. PLOS ONE, 2019, 14 (04):
  • [24] Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data
    Lu, Yihuan
    Fontaine, Kathryn
    Mulnix, Tim
    Onofrey, John A.
    Ren, Silin
    Panin, Vladimir
    Jones, Judson
    Casey, Michael E.
    Barnett, Robert
    Kench, Peter
    Fulton, Roger
    Carson, Richard E.
    Liu, Chi
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (09) : 1480 - 1486
  • [25] Improved respiratory motion self-gating in cardiovascular MRI
    Yu Gao
    Ziwu Zhou
    Fei Han
    Paul J Finn
    Peng Hu
    [J]. Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [26] Self-gated cardiac Cine MRI of the rat on a clinical 3T MRI system
    Kraemer, Martin
    Herrmann, Karl-Heinz
    Biermann, Judith
    Freiburger, Sebastian
    Schwarzer, Michael
    Reichenbach, Juergen R.
    [J]. NMR IN BIOMEDICINE, 2015, 28 (02) : 162 - 167
  • [27] Respiratory motion-resolved, self-gated 4D-MRI using Rotating Cartesian K-space (ROCK): Initial clinical experience on an MRI-guided radiotherapy system
    Han, Fei
    Zhou, Ziwu
    Du, Dongsu
    Gao, Yu
    Rashid, Shams
    Cao, Minsong
    Shaverdian, Narek
    Hegde, John V.
    Steinberg, Michael
    Lee, Percy
    Raldow, Ann
    Low, Daniel A.
    Sheng, Ke
    Yang, Yingli
    Hu, Peng
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 (03) : 467 - 473
  • [28] Motion Correction for Respiratory Gated PET Images
    Detorie, Nicole
    Dahlbom, Magnus
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3273 - 3277
  • [29] Motion Correction Options in PET/MRI
    Catana, Ciprian
    [J]. SEMINARS IN NUCLEAR MEDICINE, 2015, 45 (03) : 212 - 223
  • [30] Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom
    Yue, Y.
    Fan, Z.
    Yang, W.
    Pang, J.
    McKenzie, E.
    Deng, Z.
    Tuli, R.
    Sandler, H.
    Li, D.
    Fraass, B.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 572 - 573