Evaluation of a multiplex liquid chromatography-tandem mass spectrometry method for congenital adrenal hyperplasia in pediatric patients

被引:2
|
作者
Cao, Jing [1 ,2 ]
Sonilal, Marilyn [2 ]
Roper, Stephen M. [3 ,4 ]
Ali, Mahesheema [1 ,2 ]
Devaraj, Sridevi [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pathol & Immunol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Dept Pathol, Houston, TX 77030 USA
[3] Washington Univ, Sch Med, St Louis, MO USA
[4] St Louis Childrens Hosp, St Louis, MO 63178 USA
关键词
Congenital adrenal hyperplasia; Adrenal steroid hormone; Liquid chromatography; Tandem mass spectrometry; Interference;
D O I
10.1016/j.clinms.2018.07.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Multiplexed adrenal steroid measurement provides critical diagnostic information for patients with congenital adrenal hyperplasia (CAH) as confirmation of newborn screening (NBS) or as initial diagnosis. This study reports the implementation of an adrenal steroid profiling method with a turnaround time (TAT) of less than 24 h using liquid chromatography and tandem-mass spectrometry (LC-MS/MS). A lab-developed multiplexed LC-MS/MS assay was used to quantify levels of 11-deoxycortisol, cortisol, 17-hydroxy-progesterone (17-OHP), androstenedione, and testosterone. Intra and interassay imprecision were found to be < 10%. Comparison with a reference laboratory revealed < 20% bias for all 5 analytes and Deming correlation coefficients > 0.990. Linearity ranges were established from the lowest to upper limit calibrator concentrations with 100- to 800-fold maximum dilution. Run to run carryover was < 0.1%, and acceptable matrix effect was observed (i.e., ion suppression enhancement < 15%). Compared to serum samples, ethylenediaminetetraacetic acid (EDTA) and heparin plasma had large positive bias in the measurement of 11-deoxycortisol (62.2% and 60.2%, respectively) and androstenedione (43.8% and 33.2%, respectively), while cortisol, 17-OHP and testosterone showed less than 20% bias between sample types. Hemoglobin, bilirubin, or triglyceride interference decreased 11-deoxycortisol measurement in EDTA plasma (-19.3%, -25.6%, and -25.0%, respectively). Lipemia increased the measurement of testosterone by 28.9%. In summary, our multiplexed LC-MS/MS method provided highly sensitive and specific measurement of adrenal steroids. EDTA, heparin, hemolysis, icterus and/or lipemia may significantly impact assay results and should be avoided. This method provides an effective strategy for improving TAT in CAH testing and confirmation of NBS results.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [21] Clinical applications of genetic analysis and liquid chromatography tandem-mass spectrometry in rare types of congenital adrenal hyperplasia
    Zhuoguang Li
    Yan Liang
    Caiqi Du
    Xiao Yu
    Ling Hou
    Wei Wu
    Yanqing Ying
    Xiaoping Luo
    [J]. BMC Endocrine Disorders, 21
  • [22] Analysis of acrylamide in different foodstuffs using liquid chromatography-tandem mass spectrometry and gas chromatography-tandem mass spectrometry
    Hoenicke, K
    Gatermann, R
    Harder, W
    Hartig, L
    [J]. ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 207 - 215
  • [23] Method for the Quantification of Diamorphine and its Metabolites in Pediatric Plasma Samples by liquid Chromatography-Tandem Mass Spectrometry
    Al-Asmari, Ahmed
    Anderson, Robert A.
    Kidd, Susan
    Thomson, Alison H.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2010, 34 (04) : 177 - 195
  • [24] An automated method on analysis of blood steroids using liquid chromatography tandem mass spectrometry: Application to population screening for congenital adrenal hyperplasia in newborns
    Dhillon, Kuldeep
    Ho, Thomson
    Rich, Patti
    Xu, Dadong
    Lorey, Fred
    She, Jianwen
    Bhandal, Ajit
    [J]. CLINICA CHIMICA ACTA, 2011, 412 (23-24) : 2076 - 2084
  • [25] LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY APPLICATIONS IN ENDOCRINOLOGY
    Kushnir, Mark M.
    Rockwood, Alan L.
    Bergquist, Jonas
    [J]. MASS SPECTROMETRY REVIEWS, 2010, 29 (03) : 480 - 502
  • [26] HYDROPHILIC INTERACTION LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Ji, Hye Young
    Park, Eun Jung
    Chang, Bo Yoon
    Kim, Sung Yeon
    Lee, Hye Suk
    [J]. DRUG METABOLISM REVIEWS, 2008, 40 : 45 - 45
  • [27] Liquid chromatography-tandem mass spectrometry for clinical diagnostics
    不详
    [J]. NATURE REVIEWS METHODS PRIMERS, 2022, 2 (01):
  • [28] Mediator lipidomics by liquid chromatography-tandem mass spectrometry
    Kita, Yoshihiro
    Tokuoka, Suzumi M.
    Shimizu, Takao
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2017, 1862 (08): : 777 - 781
  • [29] Determination of dalcetrapib by liquid chromatography-tandem mass spectrometry
    Heinig, Katja
    Bucheli, Franz
    Kuhlmann, Olaf
    Zell, Manfred
    Paehler, Axel
    Zwanziger, Elke
    Gross, Guenter
    Tardio, Joseph
    Ishikawa, Tomohiro
    Yamashita, Tomoko
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 314 - 324
  • [30] Ocrelizumab quantitation by liquid chromatography-tandem mass spectrometry
    Hallin, Erik I.
    Serkland, Trond Traetteberg
    Myhr, Kjell-Morten
    Torkildsen, Oivind Grytten
    Skrede, Silje
    [J]. JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2022, 25 : 53 - 60