An automated method on analysis of blood steroids using liquid chromatography tandem mass spectrometry: Application to population screening for congenital adrenal hyperplasia in newborns

被引:23
|
作者
Dhillon, Kuldeep [1 ]
Ho, Thomson [1 ]
Rich, Patti [1 ]
Xu, Dadong [2 ]
Lorey, Fred [3 ]
She, Jianwen [4 ]
Bhandal, Ajit [1 ]
机构
[1] Calif Dept Publ Hlth, Genet Dis Lab Branch, Richmond, CA 94804 USA
[2] Calif Dept Publ Hlth, Sanitat & Radiat Lab Branch, Richmond, CA 94804 USA
[3] Calif Dept Publ Hlth, Genet Dis Screening Program, Richmond, CA 94804 USA
[4] Calif Dept Publ Hlth, Environm Hlth Lab Branch, Richmond, CA 94804 USA
关键词
LC-MS/MS; Enzyme immunoassay; Congenital adrenal hyperplasia; Steroids; 17-alpha-hydroxyprogestrone; Newborn screening; 21-HYDROXYLASE DEFICIENCY; 17-HYDROXYPROGESTERONE LEVELS; PREDICTIVE-VALUE; PRETERM INFANTS; 17-ALPHA-HYDROXYPROGESTERONE; DIAGNOSIS; IMPROVES; PLASMA; SPOTS;
D O I
10.1016/j.cca.2011.07.009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Newborn screening for congenital adrenal hyperplasia (CAH) is commonly accomplished by measurement of 17-alpha-hydroxyprogestrone (17-OHP) using enzyme immunoassay (EIA). EIA contributes a significant number of false positives. Therefore, second-tier steroid profile by liquid chromatography-tandem mass spectrometry (LC-MS/MS) is warranted. Methods: Dried blood spots (DBS) were extracted with a mixture of methanol and water containing the deuterium labeled internal standards of d(8)-17-OHP, d(7)-androstenedione, and d(4)-cortisol. The final extracts were analyzed for 17-OHP, androstenedione and cortisol by LC-MS/MS in the multiple reaction monitoring (MRM) mode. Results: Mean recoveries of the target analytes, 17-OHP, androstenedione and cortisol, were between 97 and 115% with an average intra- and inter-assay CVs ranging from 3.9-9.9% to 3.6-10.1%, respectively. The high efficiency of this method enabled us to test 11,598 specimens, identified as indeterminate by EIA in similar to 6 years; resulting in 809 presumptive positives reducing the false positives rate by 93%. Conclusions: The three steroid profile provided better screening outcomes of CAH than 17-OHP concentration alone. Our sample preparation allowed high throughput using common laboratory chemicals. Using three internal standards significantly improved method precision and accuracy. The reduction in false positives significantly reduces anxiety for newborns and their families. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:2076 / 2084
页数:9
相关论文
共 50 条
  • [1] Screening for Nonclassic Congenital Adrenal Hyperplasia in the Era of Liquid Chromatography-Tandem Mass Spectrometry
    Chesover, Alexander D.
    Millar, Heather
    Sepiashvili, Lusia
    Adeli, Khosrow
    Palmert, Mark R.
    Hamilton, Jill
    [J]. JOURNAL OF THE ENDOCRINE SOCIETY, 2020, 4 (02)
  • [2] Steroid profile in dried blood spots by liquid chromatography tandem mass spectrometry: Application to newborn screening for congenital adrenal hyperplasia in China
    Zhan, Xia
    Han, Lianshu
    Qiu, Wenjuan
    Gu, Xuefan
    Guo, Jun
    Chang, Siyu
    Wang, Yu
    Zhang, Huiwen
    [J]. STEROIDS, 2022, 185
  • [3] Newborn screening for congenital adrenal hyperplasia: Additional steroid profile using liquid chromatography-tandem mass spectrometry
    Janzen, N.
    Peter, M.
    Sander, S.
    Steuerwald, U.
    Terhardt, M.
    Holtkamp, U.
    Sander, J.
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2007, 92 (07): : 2581 - 2589
  • [4] Serum steroid profiling for Congenital Adrenal Hyperplasia using liquid chromatography-tandem mass spectrometry
    Rossi, Claudia
    Calton, Lisa
    Hammond, Gareth
    Brown, Heather A.
    Wallace, A. Michael
    Sacchetta, Paolo
    Morris, Michael
    [J]. CLINICA CHIMICA ACTA, 2010, 411 (3-4) : 222 - 228
  • [5] Measuring steroids from dried blood spots using tandem mass spectrometry to diagnose congenital adrenal hyperplasia
    Qasrawi, Deema O.
    Boyd, Jessica M.
    Sadrzadeh, S. M. H.
    [J]. CLINICA CHIMICA ACTA, 2021, 520 : 202 - 207
  • [6] Evaluation of a multiplex liquid chromatography-tandem mass spectrometry method for congenital adrenal hyperplasia in pediatric patients
    Cao, Jing
    Sonilal, Marilyn
    Roper, Stephen M.
    Ali, Mahesheema
    Devaraj, Sridevi
    [J]. CLINICAL MASS SPECTROMETRY, 2018, 9 : 18 - 22
  • [7] The use of liquid chromatography-tandem mass spectrometry in newborn screening for congenital adrenal hyperplasia: improvements and future perspectives
    de Hora, Mark
    Heather, Natasha
    Webster, Dianne
    Albert, Benjamin
    Hofman, Paul
    [J]. FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [8] Rapid blood spot quantification of steroids relevant for Congenital Adrenal Hyperplasia (CAH) using UPLC tandem mass spectrometry
    Janzen, N.
    Sander, S.
    Terhardt, M.
    Peter, M.
    Das, A. M.
    Sander, J.
    [J]. CLINICAL BIOCHEMISTRY, 2011, 44 (07) : 533 - 534
  • [9] Clinical applications of genetic analysis and liquid chromatography tandem-mass spectrometry in rare types of congenital adrenal hyperplasia
    Li, Zhuoguang
    Liang, Yan
    Du, Caiqi
    Yu, Xiao
    Hou, Ling
    Wu, Wei
    Ying, Yanqing
    Luo, Xiaoping
    [J]. BMC ENDOCRINE DISORDERS, 2021, 21 (01)
  • [10] Clinical applications of genetic analysis and liquid chromatography tandem-mass spectrometry in rare types of congenital adrenal hyperplasia
    Zhuoguang Li
    Yan Liang
    Caiqi Du
    Xiao Yu
    Ling Hou
    Wei Wu
    Yanqing Ying
    Xiaoping Luo
    [J]. BMC Endocrine Disorders, 21