Evaluation of a multiplex liquid chromatography-tandem mass spectrometry method for congenital adrenal hyperplasia in pediatric patients

被引:2
|
作者
Cao, Jing [1 ,2 ]
Sonilal, Marilyn [2 ]
Roper, Stephen M. [3 ,4 ]
Ali, Mahesheema [1 ,2 ]
Devaraj, Sridevi [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pathol & Immunol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Dept Pathol, Houston, TX 77030 USA
[3] Washington Univ, Sch Med, St Louis, MO USA
[4] St Louis Childrens Hosp, St Louis, MO 63178 USA
关键词
Congenital adrenal hyperplasia; Adrenal steroid hormone; Liquid chromatography; Tandem mass spectrometry; Interference;
D O I
10.1016/j.clinms.2018.07.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Multiplexed adrenal steroid measurement provides critical diagnostic information for patients with congenital adrenal hyperplasia (CAH) as confirmation of newborn screening (NBS) or as initial diagnosis. This study reports the implementation of an adrenal steroid profiling method with a turnaround time (TAT) of less than 24 h using liquid chromatography and tandem-mass spectrometry (LC-MS/MS). A lab-developed multiplexed LC-MS/MS assay was used to quantify levels of 11-deoxycortisol, cortisol, 17-hydroxy-progesterone (17-OHP), androstenedione, and testosterone. Intra and interassay imprecision were found to be < 10%. Comparison with a reference laboratory revealed < 20% bias for all 5 analytes and Deming correlation coefficients > 0.990. Linearity ranges were established from the lowest to upper limit calibrator concentrations with 100- to 800-fold maximum dilution. Run to run carryover was < 0.1%, and acceptable matrix effect was observed (i.e., ion suppression enhancement < 15%). Compared to serum samples, ethylenediaminetetraacetic acid (EDTA) and heparin plasma had large positive bias in the measurement of 11-deoxycortisol (62.2% and 60.2%, respectively) and androstenedione (43.8% and 33.2%, respectively), while cortisol, 17-OHP and testosterone showed less than 20% bias between sample types. Hemoglobin, bilirubin, or triglyceride interference decreased 11-deoxycortisol measurement in EDTA plasma (-19.3%, -25.6%, and -25.0%, respectively). Lipemia increased the measurement of testosterone by 28.9%. In summary, our multiplexed LC-MS/MS method provided highly sensitive and specific measurement of adrenal steroids. EDTA, heparin, hemolysis, icterus and/or lipemia may significantly impact assay results and should be avoided. This method provides an effective strategy for improving TAT in CAH testing and confirmation of NBS results.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [1] Screening for Nonclassic Congenital Adrenal Hyperplasia in the Era of Liquid Chromatography-Tandem Mass Spectrometry
    Chesover, Alexander D.
    Millar, Heather
    Sepiashvili, Lusia
    Adeli, Khosrow
    Palmert, Mark R.
    Hamilton, Jill
    [J]. JOURNAL OF THE ENDOCRINE SOCIETY, 2020, 4 (02)
  • [2] Serum steroid profiling for Congenital Adrenal Hyperplasia using liquid chromatography-tandem mass spectrometry
    Rossi, Claudia
    Calton, Lisa
    Hammond, Gareth
    Brown, Heather A.
    Wallace, A. Michael
    Sacchetta, Paolo
    Morris, Michael
    [J]. CLINICA CHIMICA ACTA, 2010, 411 (3-4) : 222 - 228
  • [3] Newborn screening for congenital adrenal hyperplasia: Additional steroid profile using liquid chromatography-tandem mass spectrometry
    Janzen, N.
    Peter, M.
    Sander, S.
    Steuerwald, U.
    Terhardt, M.
    Holtkamp, U.
    Sander, J.
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2007, 92 (07): : 2581 - 2589
  • [4] The use of liquid chromatography-tandem mass spectrometry in newborn screening for congenital adrenal hyperplasia: improvements and future perspectives
    de Hora, Mark
    Heather, Natasha
    Webster, Dianne
    Albert, Benjamin
    Hofman, Paul
    [J]. FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [5] Steroid profiling for the diagnosis of congenital adrenal hyperplasia by microbore ultra-performance liquid chromatography-tandem mass spectrometry
    Feng, Disheng
    Wang, Zixuan
    Li, Hang
    Shi, Xianzhe
    Zou, Lin
    Kong, Hongwei
    Xu, Zhiliang
    Yu, Chaowen
    Hu, Chunxiu
    Xu, Guowang
    [J]. CLINICA CHIMICA ACTA, 2023, 543
  • [6] Implementing steroid profiling by liquid chromatography-tandem mass spectrometry improves newborn screening for congenital adrenal hyperplasia in New Zealand
    de Hora, Mark R.
    Heather, Natasha L.
    Patel, Tejal
    Bresnahan, Lauren G.
    Webster, Dianne
    Hofman, Paul L.
    [J]. CLINICAL ENDOCRINOLOGY, 2021, 94 (06) : 904 - 912
  • [7] Liquid chromatography-tandem mass spectrometry
    Petrovic, Mira
    Barcelo, Damia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (18) : 5857 - 5858
  • [8] Diagnosis of adrenal cortical dysfunction by liquid chromatography-tandem mass spectrometry
    Kao, PC
    Machacek, DA
    Magera, MJ
    Lacey, JM
    Rinaldo, P
    [J]. ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2001, 31 (02): : 199 - 204
  • [9] Rapid steroid hormone quantification for congenital adrenal hyperplasia (CAH) in dried blood spots using UPLC liquid chromatography-tandem mass spectrometry
    Janzen, Nils
    Sander, Stefanie
    Terhardt, Michael
    Steuerwald, Ulrike
    Peter, Michael
    Das, Anibh M.
    Sander, Johannes
    [J]. STEROIDS, 2011, 76 (13) : 1437 - 1442
  • [10] Serum Steroid Profiling by Liquid Chromatography-Tandem Mass Spectrometry for the Rapid Confirmation and Early Treatment of Congenital Adrenal Hyperplasia: A Neonatal Case Report
    Cicalini, Ilaria
    Tumini, Stefano
    Guidone, Paola Irma
    Pieragostino, Damiana
    Zucchelli, Mirco
    Franchi, Sara
    Lisi, Gabriele
    Chiesa, Pierluigi Lelli
    Stuppia, Liborio
    De Laurenzi, Vincenzo
    Rossi, Claudia
    [J]. METABOLITES, 2019, 9 (12)