Evaluation of a multiplex liquid chromatography-tandem mass spectrometry method for congenital adrenal hyperplasia in pediatric patients

被引:2
|
作者
Cao, Jing [1 ,2 ]
Sonilal, Marilyn [2 ]
Roper, Stephen M. [3 ,4 ]
Ali, Mahesheema [1 ,2 ]
Devaraj, Sridevi [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pathol & Immunol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Dept Pathol, Houston, TX 77030 USA
[3] Washington Univ, Sch Med, St Louis, MO USA
[4] St Louis Childrens Hosp, St Louis, MO 63178 USA
关键词
Congenital adrenal hyperplasia; Adrenal steroid hormone; Liquid chromatography; Tandem mass spectrometry; Interference;
D O I
10.1016/j.clinms.2018.07.001
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Multiplexed adrenal steroid measurement provides critical diagnostic information for patients with congenital adrenal hyperplasia (CAH) as confirmation of newborn screening (NBS) or as initial diagnosis. This study reports the implementation of an adrenal steroid profiling method with a turnaround time (TAT) of less than 24 h using liquid chromatography and tandem-mass spectrometry (LC-MS/MS). A lab-developed multiplexed LC-MS/MS assay was used to quantify levels of 11-deoxycortisol, cortisol, 17-hydroxy-progesterone (17-OHP), androstenedione, and testosterone. Intra and interassay imprecision were found to be < 10%. Comparison with a reference laboratory revealed < 20% bias for all 5 analytes and Deming correlation coefficients > 0.990. Linearity ranges were established from the lowest to upper limit calibrator concentrations with 100- to 800-fold maximum dilution. Run to run carryover was < 0.1%, and acceptable matrix effect was observed (i.e., ion suppression enhancement < 15%). Compared to serum samples, ethylenediaminetetraacetic acid (EDTA) and heparin plasma had large positive bias in the measurement of 11-deoxycortisol (62.2% and 60.2%, respectively) and androstenedione (43.8% and 33.2%, respectively), while cortisol, 17-OHP and testosterone showed less than 20% bias between sample types. Hemoglobin, bilirubin, or triglyceride interference decreased 11-deoxycortisol measurement in EDTA plasma (-19.3%, -25.6%, and -25.0%, respectively). Lipemia increased the measurement of testosterone by 28.9%. In summary, our multiplexed LC-MS/MS method provided highly sensitive and specific measurement of adrenal steroids. EDTA, heparin, hemolysis, icterus and/or lipemia may significantly impact assay results and should be avoided. This method provides an effective strategy for improving TAT in CAH testing and confirmation of NBS results.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [41] Improved method for concurrent quantification of antiretrovirals by liquid chromatography-tandem mass spectrometry
    Ghoshal, AK
    Soldin, SJ
    [J]. THERAPEUTIC DRUG MONITORING, 2003, 25 (04) : 497 - 497
  • [42] Optimisation and validation of a liquid chromatography-tandem mass spectrometry method for folates in rice
    De Brouwer, Veerle
    Storozhenko, Sergei
    Van de Steene, Jet C.
    Wille, Sarah M. R.
    Stove, Christophe P.
    Van Der Straeten, Dominique
    Lambert, Willy E.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1215 (1-2) : 125 - 132
  • [43] A liquid chromatography-tandem mass spectrometry method for the analysis of biomarkers of acrylamide exposure
    Ospina, M
    Vesper, H
    Meyers, T
    Smith, A
    Gray, G
    Ingham, L
    Myers, G
    [J]. ENVIRONMENTAL EXPOSURE AND HEALTH, 2005, 85 : 187 - 194
  • [44] Determination of tandospirone in human plasma by a liquid chromatography-tandem mass spectrometry method
    Jin, Fengdan
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 2881 - 2887
  • [45] Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Trimetazidine in Human Plasma
    Zou, Jianjun
    Dai, Li
    Wang, Guang Ji
    Zhu, Yubing
    Fan, Hongwei
    Xiao, Da Wei
    [J]. ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2008, 58 (09): : 429 - 434
  • [46] Measurement of teicoplanin by liquid chromatography-tandem mass spectrometry: development of a novel method
    Fung, Francis H. Y.
    Tang, Jonathan C. Y.
    Hopkins, John P. P.
    Dutton, John J.
    Bailey, Lisa M.
    Davison, Andrew S.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2012, 49 : 475 - 481
  • [47] A novel liquid chromatography-tandem mass spectrometry method for assessing renal function
    Molinaro, Ross. J.
    Ritchie, James C.
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (03) : 472 - 472
  • [48] Liquid chromatography-tandem mass spectrometry method for the determination of anthelmintics in alfalfa plants
    Islam, M. Dabalus
    Haberhauer, G.
    Gerzabek, M.
    Cannavan, A.
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (11): : 1679 - 1688
  • [49] A rapid quantitative method of carisoprodol and meprobamate by liquid chromatography-tandem mass spectrometry
    Essler, Shannon
    Bruns, Kerry
    Frontz, Michael
    McCutcheon, J. Rod
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 908 : 155 - 160
  • [50] Quantification and Validation of Ertapenem Using a Liquid Chromatography-Tandem Mass Spectrometry Method
    van Rijn, S. P.
    Wessels, A. M. A.
    Greijdanus, B.
    Touw, D. J.
    Alffenaar, J. W. C.
    [J]. ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2014, 58 (06) : 3481 - 3484