Sub-20 nm x-ray nanolithography using conventional mask technologies on monochromatized synchrotron radiation

被引:23
|
作者
Simon, G [1 ]
Haghiri-Gosnet, AM
Bourneix, J
Decanini, D
Chen, Y
Rousseaux, F
Launois, H
Vidal, B
机构
[1] CNRS, Microstruct & Microelect Lab, L2M, F-92225 Bagneux, France
[2] Univ Aix Marseille, URA 843, Fac Sci St Jerome, F-13397 Marseille 20, France
来源
关键词
D O I
10.1116/1.589672
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The optimal wavelength range for x-ray lithography is usually estimated between 0.8 and 1.4 nm. In this work, the use of a monochromator working at 1.1 nm on synchrotron radiation is reported. Replication results in this monochromatic mode are compared with results obtained for a polychromatic synchrotron radiation centered at 0.8 nm in terms of resolution and image contrast, Two conventional mask technologies are used for this study. The influence of the mask contrast is also studied. A nondestructive soft contact system was chosen to lower the gap below 1 mu m. An ultimate resolution of 20 nm is shown in PMMA resist as well as 35 nm in PMMA/MAA (8.5%) resist for the monochromatic mode. The effect of photoelectrons created in the substrate is also investigated by replications on Si substrates coated with a Cr/Au bilayer. In addition, the daughtering of high resolution masks at 1.1 nm is successfully performed in the 20 nm range by Au electroplating. (C) 1997 American Vacuum Society.
引用
收藏
页码:2489 / 2494
页数:6
相关论文
共 50 条
  • [21] X-RAY EXPERIMENTS USING SYNCHROTRON RADIATION AT A SOURCE
    EISENBERGER, P
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (01): : 51 - 51
  • [22] SCANNING X-RAY MICROSCOPE USING SYNCHROTRON RADIATION
    HOROWITZ, P
    SCIENCE, 1972, 178 (4061) : 608 - &
  • [23] The X-ray measurements of the supermirror using synchrotron radiation
    Okajima, T
    Ichimaru, S
    Tamura, K
    Haga, K
    Ogasaka, Y
    Takahashi, S
    Fukuda, S
    Kitou, H
    Gotou, A
    Tawara, Y
    Yamashita, K
    Tsusaka, Y
    Takeda, S
    Kunieda, H
    ADVANCES IN X-RAY OPTICS, 2001, 4145 : 53 - 60
  • [24] X-ray diffraction microtomography using synchrotron radiation
    Barroso, RC
    Lopes, RT
    de Jesus, EFO
    Oliveira, LF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 75 - 79
  • [25] X-RAY TOPOGRAPHY USING SYNCHROTRON-RADIATION
    WIETESKA, K
    ACTA PHYSICA POLONICA A, 1994, 86 (04) : 545 - 552
  • [26] X-RAY HOLOGRAM OBTAINED BY USING SYNCHROTRON RADIATION
    AOKI, S
    ICHIHARA, Y
    KIKUTA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1972, 11 (12) : 1857 - 1857
  • [27] ON THE DEVELOPMENT OF X-RAY MICROPROBES USING SYNCHROTRON RADIATION
    VIS, RD
    VANLANGEVELDE, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 54 (1-3): : 417 - 423
  • [28] A TUNABLE X-RAY MICROPROBE USING SYNCHROTRON RADIATION
    WU, Y
    THOMPSON, AC
    UNDERWOOD, JH
    GIAUQUE, RD
    CHAPMAN, K
    RIVERS, ML
    JONES, KW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2): : 146 - 151
  • [29] X-ray transmission microtomography using synchrotron radiation
    Lopes, RT
    Rocha, HS
    de Jesus, EFO
    Barroso, RC
    de Oliveira, LF
    Anjos, MJ
    Braz, D
    Moreira, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 604 - 607
  • [30] Study of X-ray interference using synchrotron radiation
    Jiang, JH
    Han, Y
    Wang, ZG
    Tian, YL
    Wang, GL
    Wang, L
    Zhao, Y
    Cao, M
    Li, DC
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 1998, 22 (08): : 763 - 767