Sub-20 nm x-ray nanolithography using conventional mask technologies on monochromatized synchrotron radiation

被引:23
|
作者
Simon, G [1 ]
Haghiri-Gosnet, AM
Bourneix, J
Decanini, D
Chen, Y
Rousseaux, F
Launois, H
Vidal, B
机构
[1] CNRS, Microstruct & Microelect Lab, L2M, F-92225 Bagneux, France
[2] Univ Aix Marseille, URA 843, Fac Sci St Jerome, F-13397 Marseille 20, France
来源
关键词
D O I
10.1116/1.589672
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The optimal wavelength range for x-ray lithography is usually estimated between 0.8 and 1.4 nm. In this work, the use of a monochromator working at 1.1 nm on synchrotron radiation is reported. Replication results in this monochromatic mode are compared with results obtained for a polychromatic synchrotron radiation centered at 0.8 nm in terms of resolution and image contrast, Two conventional mask technologies are used for this study. The influence of the mask contrast is also studied. A nondestructive soft contact system was chosen to lower the gap below 1 mu m. An ultimate resolution of 20 nm is shown in PMMA resist as well as 35 nm in PMMA/MAA (8.5%) resist for the monochromatic mode. The effect of photoelectrons created in the substrate is also investigated by replications on Si substrates coated with a Cr/Au bilayer. In addition, the daughtering of high resolution masks at 1.1 nm is successfully performed in the 20 nm range by Au electroplating. (C) 1997 American Vacuum Society.
引用
收藏
页码:2489 / 2494
页数:6
相关论文
共 50 条
  • [41] Matrix characterization using synchrotron radiation X-ray diffraction
    Barroso, RC
    Anjos, MJ
    Lopes, RT
    de Jesus, EFO
    Simabuco, SM
    Braz, D
    Castro, CRF
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 739 - 741
  • [42] X-RAY INSTRUMENTATION FOR BIOLOGICAL CRYSTALLOGRAPHY USING SYNCHROTRON RADIATION
    KAHN, R
    BOSSHARD, R
    FOURME, R
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 68 - 72
  • [43] SAMPLE ENVIRONMENT IN EXPERIMENTS USING X-RAY SYNCHROTRON RADIATION
    BURAS, B
    REVUE DE PHYSIQUE APPLIQUEE, 1984, 19 (09): : 697 - 703
  • [44] X-RAY TOMOGRAPHIC MICROSCOPY (XTM) USING SYNCHROTRON RADIATION
    KINNEY, JH
    NICHOLS, MC
    ANNUAL REVIEW OF MATERIALS SCIENCE, 1992, 22 : 121 - 152
  • [45] X-ray fluorescence analysis using synchrotron radiation (SYXRF)
    Haller, M
    Knochel, A
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1996, 14 (03): : 461 - 488
  • [46] CRYSTAL ASSESSMENT BY X-RAY TOPOGRAPHY USING SYNCHROTRON RADIATION
    TANNER, BK
    PROGRESS IN CRYSTAL GROWTH AND CHARACTERIZATION OF MATERIALS, 1977, 1 (01): : 23 - 56
  • [47] REVIEW OF X-RAY FLUORESCENT ANALYSIS USING SYNCHROTRON RADIATION
    BARYSHEV, VB
    KULIPANOV, GN
    SKRINSKY, AN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 739 - 750
  • [48] EXPERIMENTS IN X-RAY HOLOGRAPHIC MICROSCOPY USING SYNCHROTRON RADIATION
    HOWELLS, MR
    IAROCCI, MA
    KIRZ, J
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1986, 3 (12): : 2171 - 2178
  • [49] A novel nanochannel fabrication for nanofluidic applications using synchrotron radiation via a micro patterned X-ray mask
    Jeon, Hyungkook
    Kim, Jong Hyun
    Lim, Geunbae
    RSC ADVANCES, 2016, 6 (52): : 46068 - 46072
  • [50] X-RAY TOPOGRAPHY OF NATURAL BERYL USING SYNCHROTRON AND CONVENTIONAL SOURCES
    HERRES, N
    LANG, AR
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1983, 16 (FEB) : 47 - 56