X-ray transmission microtomography using synchrotron radiation

被引:10
|
作者
Lopes, RT
Rocha, HS
de Jesus, EFO
Barroso, RC
de Oliveira, LF
Anjos, MJ
Braz, D
Moreira, S
机构
[1] Univ Fed Rio de Janeiro, COPPE, Nucl Instrumentat Lab, BR-21945970 Rio De Janeiro, Brazil
[2] Univ Estado Rio De Janeiro, Rio De Janeiro, Brazil
[3] Univ Estadual Campinas, Campinas, SP, Brazil
关键词
microtomography; synchrotron; NDT; X-ray;
D O I
10.1016/S0168-9002(03)01157-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work reports the feasibility of a non-destructive synchrotron radiation X-ray transmission imaging technique development at Brazilian synchrotron light source. The quality control image parameters (spatial and density resolution and noise) are given and microtomograms presented. Microtomograms of biomedical samples are presented. The tomography system was mounted into the XRF beamline that uses a high-intensity white beam with 12 keV effective energy, and maximum width and height equals to 11 and 1 mm, respectively. The detector used to collect the data was a 512-pixel Hamamatsu linear array with width of 50 mum (36 mum of sensitivity length) and cooled by a Peltier junction, causing the temperature falling down to 15degreesC. The samples were placed over a computer controlled table with 0.5degrees angular resolution and turned around the center covering 360degrees. To reconstruct the sample a parallel beam filtered back-projection algorithm was used. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
下载
收藏
页码:604 / 607
页数:4
相关论文
共 50 条
  • [1] X-ray diffraction microtomography using synchrotron radiation
    Barroso, RC
    Lopes, RT
    de Jesus, EFO
    Oliveira, LF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 75 - 79
  • [2] X-RAY MICROTOMOGRAPHY WITH MONOCHROMATIC SYNCHROTRON RADIATION
    DAMICO, KL
    DECKMAN, HW
    DUNSMUIR, JH
    FLANNERY, BP
    ROBERGE, WG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1524 - 1526
  • [3] X-ray Microtomography at Shanghai Synchrotron Radiation Facility
    Chen, Rongchang
    Xie, Honglan
    Deng, Biao
    Du, Guohao
    Ren, Yuqi
    Wang, Yudan
    Zhou, Guangzhao
    Tan, Hai
    Yang, Yiming
    Xu, Liang
    Hu, Tao
    Li, Qiao
    Feng, Binggang
    Wang, Feixiang
    Xiao, Tiqiao
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [4] X-ray computed microtomography (mu CT) using synchrotron radiation (SR)
    Bonse, U
    Busch, F
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 (1-2): : 133 - 169
  • [5] USING SYNCHROTRON X-RAY MICROTOMOGRAPHY TO DETECT DEFECTS
    MILEWSKI, JO
    HMELO, AB
    DAMICO, KL
    DUNSMUIR, JH
    FERGUSON, SR
    WELDING JOURNAL, 1994, 73 (02) : 45 - 49
  • [6] Investigation of internal structure of fine granules by microtomography using synchrotron X-ray radiation
    Noguchi, Shuji
    Kajihara, Ryusuke
    Iwao, Yasunori
    Fujinami, Yukari
    Suzuki, Yoshio
    Terada, Yasuko
    Uesugi, Kentaro
    Miura, Keiko
    Itai, Shigeru
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2013, 445 (1-2) : 93 - 98
  • [7] X-ray fluorescence microtomography and polycapillary based confocal imaging using synchrotron radiation
    Vincze, L
    Vekemans, B
    Szalóki, I
    Brenker, FE
    Falkenberg, G
    Rickers, K
    Aerts, K
    Van Grieken, R
    Adams, F
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 220 - 231
  • [8] Single and double grating-based X-ray microtomography using synchrotron radiation
    Thalmann, P.
    Bikis, C.
    Hipp, A.
    Mueller, B.
    Hieber, S. E.
    Schulz, G.
    APPLIED PHYSICS LETTERS, 2017, 110 (06)
  • [9] X-ray Microtomography Using Synchrotron Radiation and its Application to Meteorites and Cosmic Dust
    Tsuchiyama, Akira
    Uesugi, Kentaro
    Nakano, Tsukasa
    INTERNATIONAL JOURNAL OF MICROGRAVITY SCIENCE AND APPLICATION, 2005, 22 (02): : 116 - 120
  • [10] The imaging of failure in structural materials by synchrotron radiation X-ray microtomography
    Wu, S. C.
    Xiao, T. Q.
    Withers, P. J.
    ENGINEERING FRACTURE MECHANICS, 2017, 182 : 127 - 156