Experimental validation of 3D printed patient-specific implants using digital image correlation and finite element analysis

被引:67
|
作者
Sutradhar, Alok [1 ,2 ]
Park, Jaejong [2 ]
Carrau, Diana [3 ]
Miller, Michael J. [1 ]
机构
[1] Ohio State Univ, Dept Plast Surg, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech & Aerosp Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Craniofacial implants; Topology optimization; Segmental bone defect; Digital image correlation; Masticatory simulation; RECONSTRUCTION; OPTIMIZATION; MODELS;
D O I
10.1016/j.compbiomed.2014.06.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
With the dawn of 3D printing technology, patient-specific implant designs are set to have a paradigm shift. A topology optimization method in designing patient-specific craniofacial implants has been developed to ensure adequate load transfer mechanism and restore the form and function of the mid-face. Patient-specific finite element models are used to design these implants and to validate whether they are viable for physiological loading such as mastication. Validation of these topology optimized finite element models using mechanical testing is a critical step. Instead of inserting the implants into a cadaver or patient, we embed the implants into the computer-aided skull model of a patient and, fuse them together to 3D print the complete skull model with the implant. Masticatory forces are applied in the molar region to simulate chewing and measure the stress-strain trajectory. Until recently, strain gages have been used to measure strains for validation. Digital Image Correlation (DIC) method is a relatively new technique for full-field strain measurement which provides a continuous deformation field data. The main objective of this study is to validate the finite element model of patient-specific craniofacial implants against the strain data from the DIC obtained during the mastication simulation and show that the optimized shapes provide adequate load-transfer mechanism. Patient-specific models are obtained from CT scans. The principal maximum and minimum strains are compared. The computational and experimental approach to designing patient-specific implants proved to be a viable technique for mid-face craniofacial reconstruction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:8 / 17
页数:10
相关论文
共 50 条
  • [31] 3D Printing Experimental Validation of the Finite Element Analysis of the Maxillofacial Model
    Shu, Jingheng
    Luo, Haotian
    Zhang, Yuanli
    Liu, Zhan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [32] Direct medical image-based Finite Element modelling for patient-specific simulation of future implants
    Giovannelli, L.
    Rodenas, J. J.
    Navarro-Jimenez, J. M.
    Tur, M.
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2017, 136 : 37 - 57
  • [33] Finite Element Analysis of Patient-Specific 3D-Printed Cranial Implant Manufactured with PMMA and PEEK: A Mechanical Comparative Study
    Moncayo-Matute, Freddy P.
    Vazquez-Silva, Efren
    Pena-Tapia, Pablo G.
    Torres-Jara, Paul B.
    Moya-Loaiza, Diana P.
    Viloria-Avila, Tony J.
    POLYMERS, 2023, 15 (17)
  • [34] Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
    Peterman, Emma L.
    Kolewe, Emily L.
    Fromen, Catherine A.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (165): : 1 - 16
  • [35] Applications and limitations of using patient-specific 3D printed molds in autologous breast reconstruction
    Hummelink S.
    Verhulst A.C.
    Maal T.J.J.
    Ulrich D.J.O.
    European Journal of Plastic Surgery, 2018, 41 (5) : 571 - 576
  • [36] Tensile testing of 3D printed material with digital image correlation
    Kaspar, Vaclav
    Zacal, Jaroslav
    Rozlivka, Jakub
    Brabec, Martin
    PROCEEDINGS OF 25TH INTERNATIONAL PHD STUDENTS CONFERENCE (MENDELNET 2018), 2018, : 429 - 434
  • [37] Patient-specific finite element analysis of popliteal stenting
    Conti, Michele
    Marconi, Michele
    Campanile, Giulia
    Reali, Alessandro
    Adami, Daniele
    Berchiolli, Raffaella
    Auricchio, Ferdinando
    MECCANICA, 2017, 52 (03) : 633 - 644
  • [38] A Systematic Approach for Making 3D-Printed Patient-Specific Implants for Craniomaxillofacial Reconstruction
    Du, Ruxu
    Su, Yu-Xiong
    Yan, Yu
    Choi, Wing Shan
    Yang, Wei-Fa
    Zhang, Chunyu
    Chen, Xianshuai
    Curtin, Justin Paul
    Ouyang, Jianglin
    Zhang, Bitao
    ENGINEERING, 2020, 6 (11) : 1291 - 1301
  • [39] Patient-specific finite element analysis of popliteal stenting
    Michele Conti
    Michele Marconi
    Giulia Campanile
    Alessandro Reali
    Daniele Adami
    Raffaella Berchiolli
    Ferdinando Auricchio
    Meccanica, 2017, 52 : 633 - 644
  • [40] 3D Patient-Specific Finite Element Model (FEM) of Intracorneal Ring Segment (ICRS) Implantation
    Seven, Ibrahim
    Grytz, Rafael
    Dupps, William J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)