Experimental validation of 3D printed patient-specific implants using digital image correlation and finite element analysis

被引:67
|
作者
Sutradhar, Alok [1 ,2 ]
Park, Jaejong [2 ]
Carrau, Diana [3 ]
Miller, Michael J. [1 ]
机构
[1] Ohio State Univ, Dept Plast Surg, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech & Aerosp Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Craniofacial implants; Topology optimization; Segmental bone defect; Digital image correlation; Masticatory simulation; RECONSTRUCTION; OPTIMIZATION; MODELS;
D O I
10.1016/j.compbiomed.2014.06.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
With the dawn of 3D printing technology, patient-specific implant designs are set to have a paradigm shift. A topology optimization method in designing patient-specific craniofacial implants has been developed to ensure adequate load transfer mechanism and restore the form and function of the mid-face. Patient-specific finite element models are used to design these implants and to validate whether they are viable for physiological loading such as mastication. Validation of these topology optimized finite element models using mechanical testing is a critical step. Instead of inserting the implants into a cadaver or patient, we embed the implants into the computer-aided skull model of a patient and, fuse them together to 3D print the complete skull model with the implant. Masticatory forces are applied in the molar region to simulate chewing and measure the stress-strain trajectory. Until recently, strain gages have been used to measure strains for validation. Digital Image Correlation (DIC) method is a relatively new technique for full-field strain measurement which provides a continuous deformation field data. The main objective of this study is to validate the finite element model of patient-specific craniofacial implants against the strain data from the DIC obtained during the mastication simulation and show that the optimized shapes provide adequate load-transfer mechanism. Patient-specific models are obtained from CT scans. The principal maximum and minimum strains are compared. The computational and experimental approach to designing patient-specific implants proved to be a viable technique for mid-face craniofacial reconstruction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:8 / 17
页数:10
相关论文
共 50 条
  • [21] Initial Clinical Experience Using 3d Printing And Patient-Specific Airway Stents: Compassionate Use Of 3d Printed Patient-Specific Airway Stents
    Young, B. P.
    Machuzak, M. S.
    Gildea, T. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [22] 3D digital image correlation evaluation of arthrodesis implants
    Shen, Victor ChuYu
    Bumgardner, Clifton H.
    Actis, Lisa
    Ritz, Joseph
    Park, Joseph
    Li, Xiaodong
    CLINICAL BIOMECHANICS, 2020, 71 : 29 - 36
  • [23] Treatment of Facial Deformities using 3D Planning and Printing of Patient-Specific Implants
    Shilo, Dekel
    Capucha, Tal
    Goldstein, Dana
    Bereznyak, Yekaterina
    Emodi, Omri
    Rachmiel, Adi
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):
  • [24] A Validation Approach for Quasistatic Numerical/Experimental Indentation Analysis in Soft Materials Using 3D Digital Image Correlation
    Felipe-Sese, Luis
    Lopez-Alba, Elias
    Hannemann, Benedikt
    Schmeer, Sebastian
    Diaz, Francisco A.
    MATERIALS, 2017, 10 (07)
  • [25] 3D Printed Patient-Specific Mould for HDR GYN Treatment
    Wadi-Ramahi, S.
    Jastaniyah, N.
    Constantinescu, C.
    Nobeh, A.
    DeBlois, F.
    MEDICAL PHYSICS, 2018, 45 (06) : E594 - E595
  • [26] A 3D Printed Patient-specific Simulator for Percutaneous Coronary Intervention
    Redondo Dieguez, Alfredo
    Cid Alvarez, Belen
    Avila Carrillo, Alejandro
    Gomez Pena, Fernando
    Ramon Gonzalez-Juanatey, Jose
    Trillo Nouche, Ramiro
    REVISTA ESPANOLA DE CARDIOLOGIA, 2019, 72 (05): : 424 - 426
  • [27] Patient-specific 3D scanned and 3D printed antimicrobial polycaprolactone wound dressings
    Muwaffak, Zaid
    Goyanes, Alvaro
    Clark, Vivienne
    Basit, Abdul W.
    Hilton, Stephen T.
    Gaisford, Simon
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2017, 527 (1-2) : 161 - 170
  • [28] Experimental Validation of Finite Element Models of Intact and Implanted Composite Hemipelvises Using Digital Image Correlation
    Ghosh, Rajesh
    Gupta, Sanjay
    Dickinson, Alexander
    Browne, Martin
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (08):
  • [29] Patient-Specific Surgical Implants Made of 3D Printed PEEK: Material, Technology, and Scope of Surgical Application
    Honigmann, Philipp
    Sharma, Neha
    Okolo, Brando
    Popp, Uwe
    Msallem, Bilal
    Thieringer, Florian M.
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [30] Validation of a finite element model of pediatric patient-specific mandible
    Zhao, LP
    Patel, PK
    Widera, GEO
    Harris, GF
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1831 - 1834