Experimental validation of 3D printed patient-specific implants using digital image correlation and finite element analysis

被引:67
|
作者
Sutradhar, Alok [1 ,2 ]
Park, Jaejong [2 ]
Carrau, Diana [3 ]
Miller, Michael J. [1 ]
机构
[1] Ohio State Univ, Dept Plast Surg, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Mech & Aerosp Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Coll Med, Columbus, OH 43210 USA
基金
美国国家科学基金会;
关键词
Craniofacial implants; Topology optimization; Segmental bone defect; Digital image correlation; Masticatory simulation; RECONSTRUCTION; OPTIMIZATION; MODELS;
D O I
10.1016/j.compbiomed.2014.06.002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
With the dawn of 3D printing technology, patient-specific implant designs are set to have a paradigm shift. A topology optimization method in designing patient-specific craniofacial implants has been developed to ensure adequate load transfer mechanism and restore the form and function of the mid-face. Patient-specific finite element models are used to design these implants and to validate whether they are viable for physiological loading such as mastication. Validation of these topology optimized finite element models using mechanical testing is a critical step. Instead of inserting the implants into a cadaver or patient, we embed the implants into the computer-aided skull model of a patient and, fuse them together to 3D print the complete skull model with the implant. Masticatory forces are applied in the molar region to simulate chewing and measure the stress-strain trajectory. Until recently, strain gages have been used to measure strains for validation. Digital Image Correlation (DIC) method is a relatively new technique for full-field strain measurement which provides a continuous deformation field data. The main objective of this study is to validate the finite element model of patient-specific craniofacial implants against the strain data from the DIC obtained during the mastication simulation and show that the optimized shapes provide adequate load-transfer mechanism. Patient-specific models are obtained from CT scans. The principal maximum and minimum strains are compared. The computational and experimental approach to designing patient-specific implants proved to be a viable technique for mid-face craniofacial reconstruction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:8 / 17
页数:10
相关论文
共 50 条
  • [41] Treatment Planning for Image-Guided Neuro-Vascular Interventions Using Patient-Specific 3D Printed Phantoms
    Russ, M.
    O'Hara, R.
    Nagesh, S. V. Setlur
    Mokin, M.
    Jimenez, C.
    Siddiqui, A.
    Bednarek, D.
    Rudin, S.
    Ionita, C.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417
  • [42] Patient-specific 3D-printed glioblastomas
    Gomez-Roman, Natividad
    Chalmers, Anthony J.
    NATURE BIOMEDICAL ENGINEERING, 2019, 3 (07) : 498 - 499
  • [43] Patient-specific 3D-printed glioblastomas
    Natividad Gomez-Roman
    Anthony J. Chalmers
    Nature Biomedical Engineering, 2019, 3 : 498 - 499
  • [44] Functional 3D Printed Patient-Specific Modeling of Severe Aortic Stenosis
    Maragiannis, Dimitrios
    Jackson, Matthew S.
    Igo, Stephen R.
    Chang, Su Min
    Zoghbi, William A.
    Little, Stephen H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (10) : 1066 - 1068
  • [45] 3D Printed Patient-Specific Cutting Guide for Anterior Midfoot Tarsectomy
    Dagneaux, Louis
    Canovas, Francois
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (02) : 211 - 215
  • [46] Patient-specific 3D printed model of biliary ducts with congenital cyst
    Allan, Amee
    Kealley, Catherine
    Squelch, Andrew
    Wong, Yin How
    Yeong, Chai Hong
    Sun, Zhonghua
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (01) : 86 - 93
  • [47] Experimental Validation of a Finite Element Model of the Proximal Femur Using Digital Image Correlation and a Composite Bone Model
    Dickinson, A. S.
    Taylor, A. C.
    Ozturk, H.
    Browne, M.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (01):
  • [48] Functional Evaluation of a Patient-specific 3D Printed Model of Aortic Regurgitation
    Vukicevic, Marija
    Maragiannis, Dimitrios
    Jackson, Matthew
    Little, Stephen H.
    CIRCULATION, 2015, 132
  • [49] Patient-Specific 3D Printed Models of Aortic Aneurysm and Aortic Dissection
    Sun, Zhonghua
    Squelch, Andrew
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (04) : 886 - 889
  • [50] Quality Control in 3D Printing: Accuracy Analysis of 3D-Printed Models of Patient-Specific Anatomy
    Dorweiler, Bernhard
    Baque, Pia Elisabeth
    Chaban, Rayan
    Ghazy, Ahmed
    Salem, Oroa
    MATERIALS, 2021, 14 (04) : 1 - 13