A non-contact camera-based method for respiratory rhythm extraction

被引:11
|
作者
Mateu-Mateus, M. [1 ]
Guede-Fernandez, F. [1 ]
Rodriguez-Ibanez, N. [2 ]
Garcia-Gonzalez, M. A. [1 ]
Ramos-Castro, J. [1 ]
Fernandez-Chimeno, M. [1 ]
机构
[1] Univ Politecn Cataluna, Dept Elect Engn, Barcelona 08034, Spain
[2] Ficosa Int SA, PI Can Mitjans S-N, Viladecavalls 08232, Barcelona, Spain
关键词
Non-contact; Camera-based; Respiration; Computer vision;
D O I
10.1016/j.bspc.2021.102443
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this work is to present a non-contact video-based method for respiratory rhythm extraction. The method makes use of a consumer-grade RGB camera, and it is based on computer vision algorithms to detect and track a custom pattern placed on the thorax of the subject. The respiratory signal is extracted by computing the changes in the position of the detected pattern through time. The method has been validated by comparing the extracted respiratory signal versus the one obtained with a reference method in adult population. The reference method was an inductive thorax plethysmography system (Respiband system from BioSignalsPlux (TM)). 21 healthy subjects were measured and four tests were performed for each subject. The respiratory signals and its respiratory cycles were extracted. To characterise the error, the respiratory cycles were assessed with: the Fisher intra-class correlation (ICC), mean absolute error (MAE), the mean absolute percentage error (MAPE) and four Bland-Altman plots were obtained. The results show a > 0.9 correlation for controlled respiration and > 0.85 for unconstrained respiration between the proposed method and the reference method, with low error results (MAPE < 4% for constrained respiration and < 6% for unconstrained respiration) and with a high sensitivity when detecting the respiratory cycles (> 94% in all cases). From the obtained results we can conclude that the proposed algorithm is adequate to acquire the respiratory signal for rhythm extraction, in real-time with a high performance when compared with the reference method, and that it could be applied to real-life situations.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [21] Non-contact identification of bridge deflection based on network camera
    Zhu Q.-K.
    Cui D.-P.
    Du Y.-F.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (06): : 146 - 155
  • [22] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [23] Mobile Camera-Based Positioning Method by Applying Landmark Corner Extraction
    Lee, Yoo Jin
    Yoon, Wansang
    Rhee, Sooahm
    KOREAN JOURNAL OF REMOTE SENSING, 2023, 39 (06) : 1309 - 1320
  • [24] Camera-Based, Non-Contact, Vital-Signs Monitoring Technology May Provide a Way for the Early Prevention of SIDS in Infants
    Zhao, Fang
    Li, Meng
    Jiang, Zhongyi
    Tsien, Joe Z.
    Lu, Zhaohui
    FRONTIERS IN NEUROLOGY, 2016, 7
  • [25] An Unobtrusive and Non-Contact Method for Respiratory Measurement With Respiratory Region Detecting Algorithm Based on Depth Images
    Sun, Chenglu
    Li, Wei
    Chen, Chen
    Wang, Zeyu
    Chen, Wei
    IEEE ACCESS, 2019, 7 : 8300 - 8315
  • [26] Camera-based measurement of respiratory rates is reliable
    Becker, Christoph
    Achermann, Stefan
    Rocque, Mukul
    Kirenko, Ihor
    Schlack, Andreas
    Dreher-Hummel, Thomas
    Zumbrunn, Thomas
    Bingisser, Roland
    Nickel, Christian H.
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2018, 25 (06) : 416 - 422
  • [27] Automatic non-contact monitoring of the respiratory rate of neonates using a structured light camera
    Gleichauf, Johanna
    Niebler, Christine
    Koelpin, Alexander
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4118 - 4121
  • [28] Non-Contact Respiratory Monitoring Using an RGB Camera for Real-World Applications
    Romano, Chiara
    Schena, Emiliano
    Silvestri, Sergio
    Massaroni, Carlo
    SENSORS, 2021, 21 (15)
  • [29] Non-Contact Respiratory Monitoring in Neonates
    Eastwood-Sutherland, Caillin
    Gale, Timothy J.
    Dargaville, Peter A.
    Wheeler, Kevin
    2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2014,
  • [30] Non-Contact HR Extraction from Different Color Spaces Using RGB Camera
    Panigrahi, Arpita
    Sharma, Hemant
    2022 NATIONAL CONFERENCE ON COMMUNICATIONS (NCC), 2022, : 332 - 337