Automatic non-contact monitoring of the respiratory rate of neonates using a structured light camera

被引:0
|
作者
Gleichauf, Johanna [1 ]
Niebler, Christine [1 ]
Koelpin, Alexander [2 ]
机构
[1] Tech Hsch Nuremberg Georg Simon Ohm, Dept Elect Engn Precis Engn & Informat Technol, Nurnberg, Germany
[2] Hamburg Univ Technol, Inst High Frequency Technol, D-21073 Hamburg, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper introduces an automatic non-contact monitoring method for measuring the respiratory rate of neonates using a structured light camera. The current monitoring bears several issues causing pressure marks, skin irritations and eczema. A structured light camera provides distance data. Our non-contact approach detects the thorax area automatically using a plane segmentation and calculates the respiratory rate from the movement of the thorax. Our method was tested and validated using the baby simulator SimBaby by Laerdal. We used different breathing rates corresponding to preterm neonates, mature neonates and babies aged up to nine months as well as two different breathing modes with differing breathing strokes. Furthermore, measurements were taken of two positions: the baby lying on its back and on its stomach.
引用
收藏
页码:4118 / 4121
页数:4
相关论文
共 50 条
  • [1] Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
    Addison, Paul S.
    Antunes, Andre
    Montgomery, Dean
    Smit, Philip
    Borg, Ulf R.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (04) : 1003 - 1010
  • [2] Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
    Paul S Addison
    André Antunes
    Dean Montgomery
    Philip Smit
    Ulf R. Borg
    [J]. Journal of Clinical Monitoring and Computing, 2023, 37 : 1003 - 1010
  • [3] Non-Contact Respiratory Monitoring in Neonates
    Eastwood-Sutherland, Caillin
    Gale, Timothy J.
    Dargaville, Peter A.
    Wheeler, Kevin
    [J]. 2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2014,
  • [4] Non-contact automatic vital signs monitoring of neonates in NICU using video camera imaging
    Khanam, Fatema-Tuz-Zohra
    Al-Naji, Ali
    Perera, Asanka G.
    Gibson, Kim
    Chahl, Javaan
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (02): : 278 - 285
  • [5] Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates
    Maurya, Lalit
    Zwiggelaar, Reyer
    Chawla, Deepak
    Mahapatra, Prasant
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (03) : 815 - 828
  • [6] Non-contact respiratory rate monitoring using thermal and visible imaging: a pilot study on neonates
    Lalit Maurya
    Reyer Zwiggelaar
    Deepak Chawla
    Prasant Mahapatra
    [J]. Journal of Clinical Monitoring and Computing, 2023, 37 : 815 - 828
  • [7] Continuous non-contact respiratory rate and tidal volume monitoring using a Depth Sensing Camera
    Addison, Paul S.
    Smit, Philip
    Jacquel, Dominique
    Addison, Anthony P.
    Miller, Cyndy
    Kimm, Gardner
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (03) : 657 - 665
  • [8] Camera-based Non-contact Respiratory Rate Estimation
    Nirmala, K.
    Kumar, C. Vinoth
    Janani, M.
    Parvathi, A. R.
    Radhika, B.
    [J]. IETE JOURNAL OF RESEARCH, 2024, 70 (05) : 5311 - 5320
  • [9] THE DEVELOPMENT OF NON-CONTACT 'TOUCHLESS' MONITORING OF RESPIRATORY RATE
    Addison, Paul S.
    Antunes, Andre
    Montgomery, Dean
    [J]. ANESTHESIA AND ANALGESIA, 2022, 134 (4S_SUPPL): : 62 - 63
  • [10] Non-contact Heart Rate Monitoring with Mobile Phone Camera
    Lin, Shu-Yen
    Tsai, Meng-Ru
    [J]. 2019 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN (ICCE-TW), 2019,