Camera-based Non-contact Respiratory Rate Estimation

被引:0
|
作者
Nirmala, K. [1 ]
Kumar, C. Vinoth [2 ]
Janani, M. [1 ]
Parvathi, A. R. [1 ]
Radhika, B. [1 ]
机构
[1] Sri Sivasubramaniya Nadar Coll Engn, Dept Biomed Engn, Chennai 603110, Tamil Nadu, India
[2] Sri Sivasubramaniya Nadar Coll Engn, Dept Elect & Commun Engn, Chennai 603110, Tamil Nadu, India
关键词
Detrend; Gaussian; Region of interest; Respiratory rate; Spirometer; Zero crossing detection;
D O I
10.1080/03772063.2023.2248934
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A non-contact-based system for estimating the respiration rate of individuals using a mobile phone camera is presented in this paper. Respiration rate is an important vital sign that indicates the number of breaths a person takes per minute and is commonly used in medical assessments. The method involves recording videos of the pit of the neck region using the mobile phone camera and analyzing the changes in light intensity within the video frames. By processing the obtained signals from the video frames, the system accurately estimates the respiration rate. The effectiveness of the proposed method and the estimated respiration rates are compared with rates obtained using two other methods: a spirometer, which is a device used to measure lung function and manual counting. The evaluation is conducted on a group of 34 participants who are instructed to breathe rapidly to simulate varying respiration rates. The results indicate that the presented method achieves an accuracy of over 80% compared with existing state-of-the-art methods. The standard deviation of & PLUSMN;3% suggests a relatively consistent performance across participants. The calculated error between the estimated respiration rates and the reference rates obtained from the spirometer and manual counting validates the reliability of the proposed approach. Additionally, the paper highlights the advantages of this system, including its cost-effectiveness and suitability for remote monitoring and mass screening. The non-contact nature of the method reduces the need for physical contact with patients, which could be especially beneficial in situations where hygiene and infection control are crucial. The paper also outlines plans for future work, which involve validating the method with larger sample sizes and exploring its potential applications in various clinical scenarios.
引用
收藏
页码:5311 / 5320
页数:10
相关论文
共 50 条
  • [1] A non-contact camera-based method for respiratory rhythm extraction
    Mateu-Mateus, M.
    Guede-Fernandez, F.
    Rodriguez-Ibanez, N.
    Garcia-Gonzalez, M. A.
    Ramos-Castro, J.
    Fernandez-Chimeno, M.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 66
  • [2] Camera-based Non-Contact Physiology Sensing
    Revanur, Ambareesh
    Jeni, Laszlo A.
    [J]. 2022 10TH INTERNATIONAL CONFERENCE ON AFFECTIVE COMPUTING AND INTELLIGENT INTERACTION WORKSHOPS AND DEMOS, ACIIW, 2022,
  • [3] CamBP: A Camera-Based, Non-Contact Blood Pressure Monitor
    Patil, Omkar R.
    Gao, Yang
    Li, Borui
    Jin, Zhanpeng
    [J]. PROCEEDINGS OF THE 2017 ACM INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND UBIQUITOUS COMPUTING AND PROCEEDINGS OF THE 2017 ACM INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS (UBICOMP/ISWC '17 ADJUNCT), 2017, : 524 - 529
  • [4] A Non-Contact Vision-Based System for Respiratory Rate Estimation
    Li, Michael H.
    Yadollahi, Azadeh
    Taati, Babak
    [J]. 2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2119 - 2122
  • [5] Non-contact cardiac pulse rate estimation based on web-camera
    Wang, Yingzhi
    Han, Tailin
    [J]. SIXTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING, 2015, 9794
  • [6] Non-Contact Infrared-Depth Camera-Based Method for Respiratory Rhythm Measurement While Driving
    Mateu-Mateus, Marc
    Guede-Fernandez, Federico
    Garcia-Gonzalez, Miguel A.
    Ramos-Castro, Juan
    Fernandez-Chimeno, Mireya
    [J]. IEEE ACCESS, 2019, 7 : 152522 - 152532
  • [7] Non-contact sensing of neonatal pulse rate using camera-based imaging: a clinical feasibility study
    Paul, M.
    Karthik, S.
    Joseph, J.
    Sivaprakasam, M.
    Kumutha, J.
    Leonhardt, S.
    Antink, C. Hoog
    [J]. PHYSIOLOGICAL MEASUREMENT, 2020, 41 (02)
  • [8] Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
    Addison, Paul S.
    Antunes, Andre
    Montgomery, Dean
    Smit, Philip
    Borg, Ulf R.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (04) : 1003 - 1010
  • [9] Robust Non-Contact Monitoring of Respiratory Rate using a Depth Camera
    Paul S Addison
    André Antunes
    Dean Montgomery
    Philip Smit
    Ulf R. Borg
    [J]. Journal of Clinical Monitoring and Computing, 2023, 37 : 1003 - 1010
  • [10] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    [J]. JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129