A non-contact camera-based method for respiratory rhythm extraction

被引:11
|
作者
Mateu-Mateus, M. [1 ]
Guede-Fernandez, F. [1 ]
Rodriguez-Ibanez, N. [2 ]
Garcia-Gonzalez, M. A. [1 ]
Ramos-Castro, J. [1 ]
Fernandez-Chimeno, M. [1 ]
机构
[1] Univ Politecn Cataluna, Dept Elect Engn, Barcelona 08034, Spain
[2] Ficosa Int SA, PI Can Mitjans S-N, Viladecavalls 08232, Barcelona, Spain
关键词
Non-contact; Camera-based; Respiration; Computer vision;
D O I
10.1016/j.bspc.2021.102443
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this work is to present a non-contact video-based method for respiratory rhythm extraction. The method makes use of a consumer-grade RGB camera, and it is based on computer vision algorithms to detect and track a custom pattern placed on the thorax of the subject. The respiratory signal is extracted by computing the changes in the position of the detected pattern through time. The method has been validated by comparing the extracted respiratory signal versus the one obtained with a reference method in adult population. The reference method was an inductive thorax plethysmography system (Respiband system from BioSignalsPlux (TM)). 21 healthy subjects were measured and four tests were performed for each subject. The respiratory signals and its respiratory cycles were extracted. To characterise the error, the respiratory cycles were assessed with: the Fisher intra-class correlation (ICC), mean absolute error (MAE), the mean absolute percentage error (MAPE) and four Bland-Altman plots were obtained. The results show a > 0.9 correlation for controlled respiration and > 0.85 for unconstrained respiration between the proposed method and the reference method, with low error results (MAPE < 4% for constrained respiration and < 6% for unconstrained respiration) and with a high sensitivity when detecting the respiratory cycles (> 94% in all cases). From the obtained results we can conclude that the proposed algorithm is adequate to acquire the respiratory signal for rhythm extraction, in real-time with a high performance when compared with the reference method, and that it could be applied to real-life situations.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [1] Non-Contact Infrared-Depth Camera-Based Method for Respiratory Rhythm Measurement While Driving
    Mateu-Mateus, Marc
    Guede-Fernandez, Federico
    Garcia-Gonzalez, Miguel A.
    Ramos-Castro, Juan
    Fernandez-Chimeno, Mireya
    IEEE ACCESS, 2019, 7 : 152522 - 152532
  • [2] Camera-based Non-contact Respiratory Rate Estimation
    Nirmala, K.
    Kumar, C. Vinoth
    Janani, M.
    Parvathi, A. R.
    Radhika, B.
    IETE JOURNAL OF RESEARCH, 2024, 70 (05) : 5311 - 5320
  • [3] Camera-Based Method for Respiratory Rhythm Extraction From a Lateral Perspective
    Mateu-Mateus, Marc
    Guede-Fernandez, Federico
    Angel Garcia-Gonzalez, Miguel
    Jose Ramos-Castro, Juan
    Fernandez-Chimeno, Mireya
    IEEE ACCESS, 2020, 8 : 154924 - 154939
  • [4] Camera-based Non-Contact Physiology Sensing
    Revanur, Ambareesh
    Jeni, Laszlo A.
    2022 10TH INTERNATIONAL CONFERENCE ON AFFECTIVE COMPUTING AND INTELLIGENT INTERACTION WORKSHOPS AND DEMOS, ACIIW, 2022,
  • [5] CamBP: A Camera-Based, Non-Contact Blood Pressure Monitor
    Patil, Omkar R.
    Gao, Yang
    Li, Borui
    Jin, Zhanpeng
    PROCEEDINGS OF THE 2017 ACM INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND UBIQUITOUS COMPUTING AND PROCEEDINGS OF THE 2017 ACM INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS (UBICOMP/ISWC '17 ADJUNCT), 2017, : 524 - 529
  • [6] Effect of Different Lighting Conditions on Camera-based Non-Contact Vital Sign Monitoring
    Raysad, Tushar
    Swarubini, P. J.
    Ganapathy, Nagarajan
    2024 IEEE APPLIED SENSING CONFERENCE, APSCON, 2024,
  • [7] Infrared Camera-Based Non-contact Measurement of Brain Activity From Pupillary Rhythms
    Park, Sangin
    Whang, Mincheol
    FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [8] Algorithmic insights of camera-based respiratory motion extraction
    Wang, Wenjin
    den Brinker, Albertus C.
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [9] Non-contact Physiological Parameters Extraction Using Camera
    Rahman, Hamidur
    Ahmed, Mobyen Uddin
    Begum, Shahina
    INTERNET OF THINGS: IOT INFRASTRUCTURES, PT I, 2016, 169 : 448 - 453
  • [10] Non-contact sensing of neonatal pulse rate using camera-based imaging: a clinical feasibility study
    Paul, M.
    Karthik, S.
    Joseph, J.
    Sivaprakasam, M.
    Kumutha, J.
    Leonhardt, S.
    Antink, C. Hoog
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (02)