摘要
The aim of this work is to present a non-contact video-based method for respiratory rhythm extraction. The method makes use of a consumer-grade RGB camera, and it is based on computer vision algorithms to detect and track a custom pattern placed on the thorax of the subject. The respiratory signal is extracted by computing the changes in the position of the detected pattern through time. The method has been validated by comparing the extracted respiratory signal versus the one obtained with a reference method in adult population. The reference method was an inductive thorax plethysmography system (Respiband system from BioSignalsPlux (TM)). 21 healthy subjects were measured and four tests were performed for each subject. The respiratory signals and its respiratory cycles were extracted. To characterise the error, the respiratory cycles were assessed with: the Fisher intra-class correlation (ICC), mean absolute error (MAE), the mean absolute percentage error (MAPE) and four Bland-Altman plots were obtained. The results show a > 0.9 correlation for controlled respiration and > 0.85 for unconstrained respiration between the proposed method and the reference method, with low error results (MAPE < 4% for constrained respiration and < 6% for unconstrained respiration) and with a high sensitivity when detecting the respiratory cycles (> 94% in all cases). From the obtained results we can conclude that the proposed algorithm is adequate to acquire the respiratory signal for rhythm extraction, in real-time with a high performance when compared with the reference method, and that it could be applied to real-life situations.
引用
下载
收藏
页数:10
相关论文
共 50 条
  • [31] Non-Contact Video-Based Neonatal Respiratory Monitoring
    Rossol, Scott L.
    Yang, Jeffrey K.
    Toney-Noland, Caroline
    Bergin, Janine
    Basavaraju, Chandan
    Kumar, Pavan
    Lee, Henry C.
    CHILDREN-BASEL, 2020, 7 (10):
  • [32] Non-Contact Measurement Method Research Based on HoloLens
    Huang Jing
    Yang Boxiong
    Chen Jiajie
    2017 INTERNATIONAL CONFERENCE ON VIRTUAL REALITY AND VISUALIZATION (ICVRV 2017), 2017, : 267 - 271
  • [33] Continuous non-contact respiratory rate and tidal volume monitoring using a Depth Sensing Camera
    Addison, Paul S.
    Smit, Philip
    Jacquel, Dominique
    Addison, Anthony P.
    Miller, Cyndy
    Kimm, Gardner
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (03) : 657 - 665
  • [34] Non-contact Measurement of Rotation Angle with Solo Camera
    Gan Xiaochuan
    Sun Anbin
    Ye Xin
    Ma Liqun
    NINTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2015, 9446
  • [35] Non-contact cardiac pulse rate estimation based on web-camera
    Wang, Yingzhi
    Han, Tailin
    SIXTH INTERNATIONAL CONFERENCE ON ELECTRONICS AND INFORMATION ENGINEERING, 2015, 9794
  • [36] Respiratory detection using non-contact sensors
    Chen Xinqiang
    Huang Zhicheng
    Su Lumei
    2020 6TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, CONTROL AND ROBOTICS (EECR 2020), 2020, 853
  • [37] Non-Contact SpO2 Prediction System Based on a Digital Camera
    Al-Naji, Ali
    Khalid, Ghaidaa A.
    Mahdi, Jinan F.
    Chahl, Javaan
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [38] Study on Non-contact Measurement of Respiratory Rate
    Sogabe Y.
    Sano M.
    Transactions of Japanese Society for Medical and Biological Engineering, 2020, 58 : 592 - 593
  • [39] Non-contact gaze tracking with head movement adaptation based on single camera
    University of Science and Technology Beijing, No.30 Xueyuan Road, Haidian district, Beijing, China
    World Acad. Sci. Eng. Technol., 2009, (395-398):
  • [40] Non-contact measurement of oxygen saturation with an RGB camera
    Guazzi, Alessandro R.
    Villarroel, Mauricio
    Jorge, Joao
    Daly, Jonathan
    Frise, Matthew C.
    Robbins, Peter A.
    Tarassenko, Lionel
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (09): : 3320 - 3338