Automatic non-contact monitoring of the respiratory rate of neonates using a structured light camera

被引:0
|
作者
Gleichauf, Johanna [1 ]
Niebler, Christine [1 ]
Koelpin, Alexander [2 ]
机构
[1] Tech Hsch Nuremberg Georg Simon Ohm, Dept Elect Engn Precis Engn & Informat Technol, Nurnberg, Germany
[2] Hamburg Univ Technol, Inst High Frequency Technol, D-21073 Hamburg, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper introduces an automatic non-contact monitoring method for measuring the respiratory rate of neonates using a structured light camera. The current monitoring bears several issues causing pressure marks, skin irritations and eczema. A structured light camera provides distance data. Our non-contact approach detects the thorax area automatically using a plane segmentation and calculates the respiratory rate from the movement of the thorax. Our method was tested and validated using the baby simulator SimBaby by Laerdal. We used different breathing rates corresponding to preterm neonates, mature neonates and babies aged up to nine months as well as two different breathing modes with differing breathing strokes. Furthermore, measurements were taken of two positions: the baby lying on its back and on its stomach.
引用
收藏
页码:4118 / 4121
页数:4
相关论文
共 50 条
  • [21] Non-contact respiration rate measurement using a single thermal camera
    Hwang, Hyeonsang
    Lee, Eui Chul
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2018, 124 : 8 - 8
  • [22] Continuous non‐contact respiratory rate and tidal volume monitoring using a Depth Sensing Camera
    Paul S. Addison
    Philip Smit
    Dominique Jacquel
    Anthony P. Addison
    Cyndy Miller
    Gardner Kimm
    Journal of Clinical Monitoring and Computing, 2022, 36 : 657 - 665
  • [23] Study on Non-contact Measurement of Respiratory Rate
    Sogabe Y.
    Sano M.
    Transactions of Japanese Society for Medical and Biological Engineering, 2020, 58 : 592 - 593
  • [24] Non-contact heart rate and respiratory monitoring based on Imaging Photoplethysmography at fingertip
    Qiao WenLong
    Zhou Liang
    Liu Zhaohui
    Yu Jiangjun
    Sun Xiaoxiao
    AOPC 2020: OPTICAL SPECTROSCOPY AND IMAGING; AND BIOMEDICAL OPTICS, 2020, 11566
  • [25] Automated Non-Contact Respiratory Rate Monitoring of Neonates Based on Synchronous Evaluation of a 3D Time-of-Flight Camera and a Microwave Interferometric Radar Sensor
    Gleichauf, Johanna
    Herrmann, Sven
    Hennemann, Lukas
    Krauss, Hannes
    Nitschke, Janina
    Renner, Philipp
    Niebler, Christine
    Koelpin, Alexander
    SENSORS, 2021, 21 (09)
  • [26] Non-contact respiration monitoring using impulse radio ultrawideband radar in neonates
    Kim, Jong Deok
    Lee, Won Hyuk
    Lee, Yonggu
    Lee, Hyun Ju
    Cha, Teahyen
    Kim, Seung Hyun
    Song, Ki-Min
    Lim, Young-Hyo
    Cho, Seok Hyun
    Cho, Sung Ho
    Park, Hyun-Kyung
    ROYAL SOCIETY OPEN SCIENCE, 2019, 6 (06):
  • [27] The Non-Contact Respiratory Monitoring System Using Thermal Image Processing
    Chiang, Ta-Chi
    Tung, Meng-Hsiung
    Hendrick
    Kurniadi, Dedi
    Wang, Zhi-hao
    Jong, Gwo-Jia
    2016 3RD INTERNATIONAL CONFERENCE ON GREEN TECHNOLOGY AND SUSTAINABLE DEVELOPMENT (GTSD), 2016, : 86 - 92
  • [28] Monitoring of sleeping animal respiratory pattern using a non-contact bioradar
    Anishchenko, L.
    Gennarelli, G.
    Tataraidze, A.
    Sviryaev, Y.
    Soldovieri, F.
    Ivashov, S.
    SLEEP MEDICINE, 2015, 16 : S92 - S92
  • [29] NON-CONTACT MONITORING OF PRETERM INFANTS USING RGB-D CAMERA
    Cenci, Annalisa
    Liciotti, Daniele
    Frontoni, Emanuele
    Mancini, Adriano
    Zingaretti, Primo
    INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 9, 2016,
  • [30] Non-contact Pulse Rate Measurement of Hand and Wrist Using RGB Camera
    Lu, Chi-Heng
    Low, Jen-Hua
    Tuan, Chiu-Ching
    ADVANCES ON BROADBAND AND WIRELESS COMPUTING, COMMUNICATION AND APPLICATIONS, BWCCA-2018, 2019, 25 : 586 - 596