Automatic non-contact monitoring of the respiratory rate of neonates using a structured light camera

被引:0
|
作者
Gleichauf, Johanna [1 ]
Niebler, Christine [1 ]
Koelpin, Alexander [2 ]
机构
[1] Tech Hsch Nuremberg Georg Simon Ohm, Dept Elect Engn Precis Engn & Informat Technol, Nurnberg, Germany
[2] Hamburg Univ Technol, Inst High Frequency Technol, D-21073 Hamburg, Germany
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper introduces an automatic non-contact monitoring method for measuring the respiratory rate of neonates using a structured light camera. The current monitoring bears several issues causing pressure marks, skin irritations and eczema. A structured light camera provides distance data. Our non-contact approach detects the thorax area automatically using a plane segmentation and calculates the respiratory rate from the movement of the thorax. Our method was tested and validated using the baby simulator SimBaby by Laerdal. We used different breathing rates corresponding to preterm neonates, mature neonates and babies aged up to nine months as well as two different breathing modes with differing breathing strokes. Furthermore, measurements were taken of two positions: the baby lying on its back and on its stomach.
引用
收藏
页码:4118 / 4121
页数:4
相关论文
共 50 条
  • [31] Non-Contact Automatic Respiration Monitoring in Restrained Rodents
    Rezaei, Behnaz
    Lowe, Jared
    Yee, Jason R.
    Porges, Stephen
    Ostadabbas, Sarah
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4946 - 4950
  • [32] Non-contact Heart Rate Monitoring Using Multiple RGB Cameras
    Ghanadian, Hamideh
    Al Osman, Hussein
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, CAIP 2019, PT II, 2019, 11679 : 85 - 95
  • [33] Non-Contact Heart Rate Monitoring Using Lab Color Space
    Rahman, Hamidur
    Ahmed, Mobyen Uddin
    Begum, Shahina
    PHEALTH 2016, 2016, 224 : 46 - 53
  • [34] Video based non-contact monitoring of respiratory rate and chest indrawing in children with pneumonia
    Lucy, Ferdous Karim
    Suha, Khadiza Tun
    Dipty, Sumaiya Tabassum
    Wadud, Md Sharjis Ibne
    Kadir, Muhammad Abdul
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (10)
  • [35] Non-Contact Monitoring of Breathing Pattern and Respiratory Rate via RGB Signal Measurement
    Massaroni, Carlo
    Lo Presti, Daniela
    Formica, Domenico
    Silvestri, Sergio
    Schena, Emiliano
    SENSORS, 2019, 19 (12)
  • [36] Non-contact measurements using light
    Woppowa, L
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2000, 60 (7-8): : 273 - 274
  • [37] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [38] Non-contact Respiration Monitoring Method for Screening Sleep Respiratory Disturbance Using Slit Light Pattern Projection
    Aoki, Hirooki
    Koshiji, Kohji
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 680 - +
  • [39] Non-contact heart rate measurement using low-cost RGB camera under complex light conditions
    Haipeng Wang
    Shuai Zhang
    Multimedia Tools and Applications, 2025, 84 (3) : 1561 - 1575
  • [40] Non-contact Measurement of Human Heart Rate Using Low Cost Video Camera
    Sharma, Naveen
    Kaman, Surjit
    Mahapatra, Prasant K.
    2019 FIFTH INTERNATIONAL CONFERENCE ON IMAGE INFORMATION PROCESSING (ICIIP 2019), 2019, : 58 - 62