Camera-based measurement of respiratory rates is reliable

被引:8
|
作者
Becker, Christoph [1 ]
Achermann, Stefan [1 ]
Rocque, Mukul [3 ]
Kirenko, Ihor [3 ]
Schlack, Andreas [3 ]
Dreher-Hummel, Thomas [1 ]
Zumbrunn, Thomas [2 ]
Bingisser, Roland [1 ]
Nickel, Christian H. [1 ]
机构
[1] Univ Hosp Basel, Dept Emergency, Basel, Switzerland
[2] Univ Hosp Basel, Clin Trial Unit, Dept Clin Res, Basel, Switzerland
[3] Philips Res, Dept Patient Care & Measurement, Eindhoven, Netherlands
关键词
clinical risk assessment; monitoring; respiratory rate; vital sign; VITAL SIGN; VALIDATION; SCORE; IDENTIFICATION; SEVERITY; RISK; CARE;
D O I
10.1097/MEJ.0000000000000476
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives Respiratory rate (RR) is one of the most important vital signs used to detect whether a patient is in critical condition. It is part of many risk scores and its measurement is essential for triage of patients in emergency departments. It is often not recorded as measurement is cumbersome and time-consuming. We intended to evaluate the accuracy of camera-based measurements as an alternative measurement to the current practice of manual counting. Materials and methods We monitored the RR of healthy male volunteers with a camera-based prototype application and simultaneously by manual counting and by capnography, which was considered the gold standard. The four assessors were mutually blinded. We simulated normoventilation, hypoventilation and hyperventilation as well as deep, normal and superficial breathing depths to assess potential clinical settings. The volunteers were assessed while being undressed, wearing a T-shirt or a winter coat. Results In total, 20 volunteers were included. The results of camera-based measurements of RRs and capnography were in close agreement throughout all clothing styles and respiratory patterns (Pearson's correlation coefficient, r=0.90-1.00, except for one scenario, in which the volunteer breathed slowly dressed in a winter coat r=0.84). In the winter-coat scenarios, the camera-based prototype application was superior to human counters. Conclusion In our pilot study, we found that camera-based measurements delivered accurate and reliable results. Future studies need to show that camera-based measurements are a secure alternative for measuring RRs in clinical settings as well. (C) 2018 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:416 / 422
页数:7
相关论文
共 50 条
  • [1] Camera-based measurement of vital signs
    Haist, Tobias
    Reichert, Carsten
    Wuertenberger, Felicia
    Lachenmaier, Lena
    Faulhaber, Andreas
    [J]. TM-TECHNISCHES MESSEN, 2019, 86 (7-8) : 354 - 361
  • [2] Camera-based measurement of cyclist motion
    Eddy, Chris
    de Saxe, Christopher
    Cebon, David
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2019, 233 (07) : 1793 - 1805
  • [3] Algorithmic insights of camera-based respiratory motion extraction
    Wang, Wenjin
    den Brinker, Albertus C.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [4] Camera-based measurement of textile card web density
    Dorrity, JL
    Zhao, F
    Carr, WW
    [J]. TEXTILE RESEARCH JOURNAL, 2003, 73 (01) : 69 - 73
  • [5] Improving the Accuracy of Camera-Based Heart Rate Measurement
    Zhu Xian-feng
    Jiao Bin
    Zhao Jing
    Li Gang
    Lin Ling
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (02) : 651 - 658
  • [6] A camera-based ballistocardiogram heart rate measurement method
    Li, Fen
    Zhao, Yuejin
    Kong, Lingqin
    Dong, Liquan
    Liu, Ming
    Hui, Mei
    Liu, Xiaohua
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (05):
  • [7] Camera-based flow measurement in open channels and rivers
    Hansen, Issa
    Satzger, Christian
    Pena-Haro, Salvador
    Luthi, Beat
    [J]. WASSERWIRTSCHAFT, 2019, 109 (7-8) : 12 - 15
  • [8] Modeling on the feasibility of camera-based blood glucose measurement
    Wang, Yiyin
    Wang, Wenjin
    van Gastel, Mark
    de Haan, Gerard
    [J]. 2019 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCVW), 2019, : 1713 - 1720
  • [9] Camera-based Curvature Measurement of a Large Incandescent Object
    Ollikkala, Arttu V. H.
    Kananen, Timo P.
    Makynen, Anssi J.
    Holappa, Markus
    [J]. OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION VIII, 2013, 8788
  • [10] Camera-based Non-contact Respiratory Rate Estimation
    Nirmala, K.
    Kumar, C. Vinoth
    Janani, M.
    Parvathi, A. R.
    Radhika, B.
    [J]. IETE JOURNAL OF RESEARCH, 2024, 70 (05) : 5311 - 5320