Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams

被引:19
|
作者
Dasu, A
Lofroth, PO
Wickman, G
机构
[1] Umea Univ, Dept Radiat Phys, S-90185 Umea, Sweden
[2] Alexandru Ioan Cuza Univ, Dept Med Phys & Biophys, R-6600 Iasi 7, Romania
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 01期
关键词
D O I
10.1088/0031-9155/43/1/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new liquid ionization chamber (LIC) design optimized for high spatial resolution was used for measurements of dose distributions in radiation fields intended for stereotactic radiosurgery (SRS). This work was mainly focused on the properties of this detector in radiation fields from linear accelerators for clinical radiotherapy (pulsed radiation with dose rates from approximately 0.5 to 5 Gy min(-1) and beam diameters down to 8 mm). The narrow beams used in stereotactic radiosurgery require detectors with small sizes in order to provide a good spatial resolution. The LIC is investigated to see whether it can be used as a detector for dose measurements in beams currently used for stereotactic radiosurgery. Its properties are compared with those of silicon diodes. The comparisons include output factor (OF), depth dose and profile measurements in 6 MV photon fields of different sizes. For OF measurements, an NACP air ionization chamber was also used in the comparison. The dependence of the response on the detector orientation in the photon beam is also investigated for the diodes and the LIC. The results suggest that LICs can provide better properties than diodes for measuring dose distributions in narrow photon beams.
引用
收藏
页码:21 / 36
页数:16
相关论文
共 50 条
  • [41] Study of Response of Plastic Scintillation Detectors in Small Field 6 MV Photon Beams
    Wang, L.
    Beddar, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [42] Reference dosimetry of FFF MV photon beams: a correction for intra-Farmer ion chamber dose gradients
    Ruggieri, R.
    Naccarato, S.
    Stavrev, P.
    Stavreva, N.
    Pasetto, S.
    Salamone, I.
    Alongi, F.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S685 - S686
  • [43] Total Scatter Factors of Small 6 MV Photon Beams Estimated by Simulating the Response of Small Detectors
    Francescon, P.
    Cora, S.
    Cavedon, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [44] RADIOSURGERY WITH UNFLATTENED 6-MV PHOTON BEAMS
    OBRIEN, PF
    GILLIES, BA
    SCHWARTZ, M
    YOUNG, C
    DAVEY, P
    MEDICAL PHYSICS, 1991, 18 (03) : 519 - 521
  • [45] Ion Recombination in a Liquid-Filled Ionization Chamber in High-Energy Photon Beams
    Chung, E.
    Davis, S.
    Seuntjens, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3887 - 3887
  • [47] High precision measurements of small fields by using liquid filled ionization chamber
    Ic, F.
    Wilhelm-Buchstab, T.
    Muedder, T.
    Schoroth, F.
    Wodarski, C.
    Garbe, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 : 137 - 137
  • [48] Small field output factor measurements: a detector comparison for Versa HD 6 MV and 6 MV FFF beams.
    Monasor Denia, P.
    Castellet Garcia, M. C.
    Manjon Garcia, C.
    Lopez Tarjuelo, J.
    Juan Senabre, X. J.
    Quiros Higueras, J. D.
    De Marco Blancas, N.
    Bonaque Alandi, J.
    Montenegro Iglesias, N.
    Santos Serra, A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S920 - S921
  • [49] Surface Dose and Build-Up Dose Comparison of 6MV and 10MV Flattened with 6MV FFF and 10MV FFF Photon Beams with Different Detectors
    Nambiraj, Arunai
    Sigamani, Ashokkumar
    Kaviarasu, K.
    Rajesh, T.
    Karthikeyan, S.
    Subramanian, Narayanan
    Meerza, Kazem
    MEDICAL PHYSICS, 2015, 42 (06) : 3502 - 3502
  • [50] COMPARISON OF PRIMARY DOSES OBTAINED IN THREE 6 MV PHOTON BEAMS USING A SMALL ATTENUATOR
    Trauernicht, Christoph
    RADIATION PROTECTION DOSIMETRY, 2017, 173 (1-3) : 198 - 202