High precision measurements of small fields by using liquid filled ionization chamber

被引:0
|
作者
Ic, F. [1 ]
Wilhelm-Buchstab, T. [2 ]
Muedder, T. [2 ]
Schoroth, F. [2 ]
Wodarski, C. [3 ]
Garbe, S. [2 ]
机构
[1] Fachbereich Med Tech & Technomath, Julich, Germany
[2] Radiol Univ Klin, Bonn, Germany
[3] MediClin Robert Janker Klin, Bonn, Germany
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
引用
收藏
页码:137 / 137
页数:1
相关论文
共 50 条
  • [1] A liquid-filled ionization chamber for high precision relative dosimetry
    Gonzalez-Castano, D. M.
    Gomez, F.
    Brualla, L.
    Rosello, J. V.
    Planes, D.
    Sanchez, M.
    Pombar, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2011, 27 (02): : 89 - 96
  • [2] NEW HIGH RESOLUTION 2D LIQUID FILLED IONIZATION CHAMBER ARRAY FOR SMALL FIELD MEASUREMENTS
    Brualla Gonzalez, L.
    Vicedo, A.
    Gonzalez-Castano, D. M.
    Gago Arias, A.
    Pardo Montero, J.
    Pazos Alvarez, A.
    Bermudez, M.
    Gomez, F.
    Rosello, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S146 - S146
  • [3] Correction of diode dose rate dependence in relative measurements of small fields using ionization chamber measurements
    Duchaine, Jasmine
    Markel, Daniel
    Bouchard, Hugo
    MEDICAL PHYSICS, 2021, 48 (08) : 4707 - 4707
  • [4] DOSIMETRIC CHARACTERISATION OF SMALL RADIOTHERAPY PHOTON FIELDS: MICRO LIQUID-FILLED IONIZATION CHAMBER COMPARED WITH CONVENTIONAL DETECTORS
    Andreoli, S.
    Colleoni, P.
    Fortunato, M.
    Moretti, R.
    Galelli, M.
    Kaiser, S. Ren
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S421 - S422
  • [5] PRECISION ELECTRONICS FOR IONIZATION-CHAMBER MEASUREMENTS
    SANTRY, DC
    BOWES, GC
    MUNZENMAYER, K
    APPLIED RADIATION AND ISOTOPES, 1987, 38 (10) : 879 - 883
  • [6] Liquid-filled ionization chamber temperature dependence
    Franco, L.
    Gomez, F.
    Iglesias, A.
    Pardo, J.
    Pazos, A.
    Pena, J.
    Zapata, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 560 (02): : 584 - 588
  • [7] Performance parameters of a liquid filled ionization chamber array
    Poppe, B.
    Stelljes, T. S.
    Looe, H. K.
    Chofor, N.
    Harder, D.
    Willborn, K.
    MEDICAL PHYSICS, 2013, 40 (08)
  • [8] Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams
    Dasu, A
    Lofroth, PO
    Wickman, G
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (01): : 21 - 36
  • [9] Comparison of a Liquid Ionization Chamber with a Diamond Detector for Relatively Small Photon Field Measurements
    Yip, C.
    Cheng, H.
    Cheung, F.
    Chan, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Calculation of correction factors for ionization chamber measurements with small fields in low-density media
    Pisaturo, O.
    Pachoud, M.
    Bochud, F. O.
    Moeckli, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (14): : 4589 - 4598