Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams

被引:19
|
作者
Dasu, A
Lofroth, PO
Wickman, G
机构
[1] Umea Univ, Dept Radiat Phys, S-90185 Umea, Sweden
[2] Alexandru Ioan Cuza Univ, Dept Med Phys & Biophys, R-6600 Iasi 7, Romania
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 01期
关键词
D O I
10.1088/0031-9155/43/1/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new liquid ionization chamber (LIC) design optimized for high spatial resolution was used for measurements of dose distributions in radiation fields intended for stereotactic radiosurgery (SRS). This work was mainly focused on the properties of this detector in radiation fields from linear accelerators for clinical radiotherapy (pulsed radiation with dose rates from approximately 0.5 to 5 Gy min(-1) and beam diameters down to 8 mm). The narrow beams used in stereotactic radiosurgery require detectors with small sizes in order to provide a good spatial resolution. The LIC is investigated to see whether it can be used as a detector for dose measurements in beams currently used for stereotactic radiosurgery. Its properties are compared with those of silicon diodes. The comparisons include output factor (OF), depth dose and profile measurements in 6 MV photon fields of different sizes. For OF measurements, an NACP air ionization chamber was also used in the comparison. The dependence of the response on the detector orientation in the photon beam is also investigated for the diodes and the LIC. The results suggest that LICs can provide better properties than diodes for measuring dose distributions in narrow photon beams.
引用
收藏
页码:21 / 36
页数:16
相关论文
共 50 条
  • [31] Determination of ion recombination correction factors for a liquid ionization chamber in megavoltage photon beams
    Sang Hyoun Choi
    Kum-Bae Kim
    Young Hoon Ji
    Chan Hyeong Kim
    Seonghoon Kim
    Hyun Do Huh
    Journal of the Korean Physical Society, 2015, 66 : 1439 - 1447
  • [32] INFLUENCE OF BONE ON 45 MV PHOTON DOSE DISTRIBUTIONS
    MCLAREN, JR
    KIRCHNER, AB
    MCGINLEY, PH
    RADIOLOGY, 1977, 125 (03) : 817 - 820
  • [33] Monte Carlo study of conversion factors for ionization chamber dosimetry in solid slab phantoms for MV photon beams
    Park, Dong-wook
    Lee, Jai-ki
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (04) : 647 - 652
  • [34] Monte Carlo study of conversion factors for ionization chamber dosimetry in solid slab phantoms for MV photon beams
    Dong-wook Park
    Jai-ki Lee
    Journal of the Korean Physical Society, 2016, 69 : 647 - 652
  • [35] SURFACE DOSE CHARACTERISTICS OF 6 AND 10MV FLATTENED AND UNFLATTENED PHOTON BEAMS
    Cashmore, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S423 - S423
  • [36] Absolute dose measurements by means of a small cylindrical ionization chamber for very high dose per pulse high energy electron beams
    Karaj, E.
    Righi, S.
    Di Martino, F.
    MEDICAL PHYSICS, 2007, 34 (03) : 952 - 958
  • [37] Calibration of a Reference Standard Ionization Chamber in 6-and 18-MV Photon Beams Using a Sealed Water Calorimeter at Room Temperature
    Bateman, F.
    Chen-Mayer, H.
    Tosh, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [38] Effects of ionization chamber orientation in photon and neutron beams
    Kirjanen, Emmi
    Wendland, Lauri
    Porra, Liisa
    Seppala, Tiina
    Tenhunen, Mikko
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1066
  • [39] COMPUTER GENERATED SCATTER DOSE DISTRIBUTIONS FOR A 6 MV RADIOTHERAPY PHOTON-BEAM
    BLOCH, P
    WALLACE, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 761 - 761
  • [40] COMPUTER GENERATED SCATTER DOSE DISTRIBUTIONS FOR A 6MV RADIOTHERAPY PHOTON BEAM
    BLOCH, P
    WALLACE, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 : 74 - 74