Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams

被引:19
|
作者
Dasu, A
Lofroth, PO
Wickman, G
机构
[1] Umea Univ, Dept Radiat Phys, S-90185 Umea, Sweden
[2] Alexandru Ioan Cuza Univ, Dept Med Phys & Biophys, R-6600 Iasi 7, Romania
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 01期
关键词
D O I
10.1088/0031-9155/43/1/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new liquid ionization chamber (LIC) design optimized for high spatial resolution was used for measurements of dose distributions in radiation fields intended for stereotactic radiosurgery (SRS). This work was mainly focused on the properties of this detector in radiation fields from linear accelerators for clinical radiotherapy (pulsed radiation with dose rates from approximately 0.5 to 5 Gy min(-1) and beam diameters down to 8 mm). The narrow beams used in stereotactic radiosurgery require detectors with small sizes in order to provide a good spatial resolution. The LIC is investigated to see whether it can be used as a detector for dose measurements in beams currently used for stereotactic radiosurgery. Its properties are compared with those of silicon diodes. The comparisons include output factor (OF), depth dose and profile measurements in 6 MV photon fields of different sizes. For OF measurements, an NACP air ionization chamber was also used in the comparison. The dependence of the response on the detector orientation in the photon beam is also investigated for the diodes and the LIC. The results suggest that LICs can provide better properties than diodes for measuring dose distributions in narrow photon beams.
引用
收藏
页码:21 / 36
页数:16
相关论文
共 50 条
  • [21] Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams
    De Vlamynck, K
    Palmans, H
    Verhaegen, F
    De Wagter, C
    De Neve, W
    Thierens, H
    MEDICAL PHYSICS, 1999, 26 (09) : 1874 - 1882
  • [22] Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams
    Bilge, Hatice
    Ozbek, Nurdan
    Okutan, Murat
    Cakir, Aydin
    Acar, Hilal
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (02): : 110 - 116
  • [23] Surface dose and build-up region measurements with wedge filters for 6 and 18 MV photon beams
    Hatice Bilge
    Nurdan Ozbek
    Murat Okutan
    Aydın Cakir
    Hilal Acar
    Japanese Journal of Radiology, 2010, 28 : 110 - 116
  • [24] Characterization of wedge factors and dose distributions in radiotherapy with symmetric and asymmetric physical wedged beams of 6 MV photon beam
    Zabihzadeh M.
    Fadaei M.
    Hoseini S.M.
    Arvandi S.
    Tahmasbi M.
    Iranian Journal of Medical Physics, 2020, 17 (03) : 213 - 219
  • [25] Properties of IBA Razor Nano Chamber in small-field radiation therapy using 6MV FF, 6 MV FFF, and 10 MV FFF photon beams
    Partanen, Mari
    Niemela, Jarkko
    Ojala, Jarkko
    Keyrilainen, Jani
    Kapanen, Mika
    ACTA ONCOLOGICA, 2021, 60 (11) : 1419 - 1424
  • [26] General ion recombination effect in a liquid ionization chamber in high-dose-rate pulsed photon and electron beams
    Takei, Hideyuki
    Isobe, Tomonori
    Kitamura, Nozomi
    Mori, Yutaro
    Tomita, Tetsuya
    Kobayashi, Daisuke
    Kamizawa, Satoshi
    Sato, Tomoharu
    Sakurai, Hideyuki
    Sakae, Takeji
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (03) : 282 - 285
  • [27] Feasibility of linear diode array based small field data acquisition for 6 MV & 15 MV photon beams - An intercomparison with micro ion chamber
    Gul, Attia
    Kakakhel, M. Basim
    Amjad, Nauman
    Razzaq, Aasia
    Mirza, Sikander M.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 162 : 146 - 152
  • [28] Influence of a Localized Transverse Magnetic Field on Dose Distributions of MV Photon Beams in Inhomogeneous Medium
    Ahn, Woo Sang
    Choi, Wonsik
    Ka, Young Ran
    Kwak, Jungwon
    Jung, In-Hye
    Ahn, Sohyun
    Shin, Seong Soo
    JOURNAL OF MAGNETICS, 2020, 25 (03) : 409 - 414
  • [29] THE INFLUENCE OF IONIZATION-CHAMBER AND PHANTOM DESIGN ON THE MEASUREMENT OF LUNG DOSE IN PHOTON BEAMS
    RICE, RK
    HANSEN, JL
    CHIN, LM
    MIJNHEER, BJ
    BJARNGARD, BE
    MEDICAL PHYSICS, 1988, 15 (06) : 884 - 890
  • [30] Determination of ion recombination correction factors for a liquid ionization chamber in megavoltage photon beams
    Choi, Sang Hyoun
    Kim, Kum-Bae
    Ji, Young Hoon
    Kim, Chan Hyeong
    Kim, Seonghoon
    Huh, Hyun Do
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (09) : 1439 - 1447