Evaluation of the Grounding Circuit Measurements for Stator Ground-Fault Location of Synchronous Generators

被引:0
|
作者
Blanquez, F. R. [1 ]
Rebollo, E. [1 ]
Platero, C. A. [1 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, E-28040 Madrid, Spain
关键词
Stator ground fault; fault location; generator protection;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Locating stator-winding ground faults accurately is a very difficult task. In this paper the grounding circuit measurements are evaluated in order to obtain information about the stator ground-fault location in synchronous generators. In power generators grounded through a high impedance, the relation between the neutral voltage and the phase voltage provide a first estimation of the fault location. The location error by using this ratio depends on the fault resistance and the value of the capacitance to ground of the stator winding. However, the error added by ignoring the value of the fault resistance is the most relevant term. This location estimation and the location error have been evaluated through the data of a real synchronous machine.
引用
收藏
页码:229 / 233
页数:5
相关论文
共 50 条
  • [1] Evaluation of the stator ground-fault protection for synchronous generators by means of the subharmonic injection method
    Giraldo, Luis C.
    Mora-Florez, Juan J.
    Olguin, Gabriel
    INGENIERIA Y COMPETITIVIDAD, 2008, 10 (01): : 21 - 30
  • [2] On-line stator ground-fault location method for synchronous generators based on 100% stator low-frequency injection protection
    Blanquez, F. R.
    Platero, C. A.
    Rebollo, E.
    Blazquez, F.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 125 : 34 - 44
  • [3] Ground-Fault Circuit Interrupters
    El-Sherif, Nehad
    Domitrovich, Thomas A.
    Reyes, Frederick P.
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2021, 27 (01) : 55 - 68
  • [4] Ground-fault currents in unit-connected generators with different elements grounding neutral
    Fulczyk, M
    Bertsch, J
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (01) : 61 - 66
  • [5] Detection and location of a ground-fault in the excitation circuit of a 106 MVA synchronous generator by a new on-line method
    Pardo, M.
    Blanquez, F. R.
    Platero, C. A.
    Rebollo, E.
    Blazquez, F.
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 140 : 303 - 311
  • [6] Impact of the Main Bonding Jumper and the Equipment Grounding Conductor on Ground-Fault Circuit Interrupters
    Rubio Perez, Maria Camila
    Ramos, Gustavo
    2018 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2018,
  • [7] Synchronous Generators Stator Ground Fault Detection Using Wavelet Theory
    Al Jaafari, Khaled
    Negahdari, Amir
    Toliyat, Hamid A.
    IECON 2018 - 44TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2018, : 707 - 713
  • [8] Experimental Verification of a Novel Adaptive Stator Ground Fault Protection Scheme for Synchronous Generators
    Al Jaafari, Khaled
    Negandari, Amir
    Toliyat, Hamid A.
    Safari-Shad, Nader
    Franklin, Russ
    2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 2237 - 2243
  • [9] Parametrization of ground-fault relays in MV distribution networks with resonant grounding
    Polajzer, Bostjan
    Pintaric, Matej
    Ribic, Janez
    Roser, Miran
    Stumberger, Gorazd
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 143
  • [10] A novel protection and precise location method based on grounding currents for stator ground faults of large generators
    Wang, Y. (wyx2005635@qq.com), 1600, Chinese Society for Electrical Engineering (33):