Evaluation of the Grounding Circuit Measurements for Stator Ground-Fault Location of Synchronous Generators

被引:0
|
作者
Blanquez, F. R. [1 ]
Rebollo, E. [1 ]
Platero, C. A. [1 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, E-28040 Madrid, Spain
关键词
Stator ground fault; fault location; generator protection;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Locating stator-winding ground faults accurately is a very difficult task. In this paper the grounding circuit measurements are evaluated in order to obtain information about the stator ground-fault location in synchronous generators. In power generators grounded through a high impedance, the relation between the neutral voltage and the phase voltage provide a first estimation of the fault location. The location error by using this ratio depends on the fault resistance and the value of the capacitance to ground of the stator winding. However, the error added by ignoring the value of the fault resistance is the most relevant term. This location estimation and the location error have been evaluated through the data of a real synchronous machine.
引用
收藏
页码:229 / 233
页数:5
相关论文
共 50 条
  • [21] Improvement of the third harmonic based stator ground fault protection for high resistance grounded synchronous generators
    Ruiz-Mondragon, Byron
    Mora-Florez, Juan
    Perez-Londono, Sandra
    REVISTA FACULTAD DE INGENIERIA-UNIVERSIDAD DE ANTIOQUIA, 2010, (52): : 215 - 225
  • [22] New Fault-Resistance Estimation Algorithm for Rotor-Winding Ground-Fault Online Location in Synchronous Machines With Static Excitation
    Blanquez, Francisco R.
    Emilio Rebollo, Maria Aranda
    Blazquez, Francisco
    Platero, Carlos A.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (03) : 1901 - 1911
  • [23] Third harmonic potential distribution based stator ground fault accurate location method for large generators
    Li, Wei
    Qiao, Jian
    Wang, Yikai
    Liu, Ren
    Lv, Tao
    Yin, Xianggen
    Liu, Feng
    ENERGY REPORTS, 2022, 8 : 21 - 28
  • [24] An Adaptive Load-Based Location Method of Stator Ground Fault for Large Hydro-Generators
    Tan L.
    Yin X.
    Wang Y.
    Qiao J.
    Xu W.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2022, 37 (17): : 4411 - 4422
  • [25] A Precise Stator Ground Fault Location Method for Large Generators Based on Potential Analysis of Slot Conductors
    Qiao, Jian
    Yin, Xianggen
    Wang, Yikai
    Tan, Liming
    Lu, Qinghui
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (06) : 5203 - 5213
  • [26] Third harmonic potential distribution based stator ground fault accurate location method for large generators
    Li, Wei
    Qiao, Jian
    Wang, Yikai
    Liu, Ren
    Lv, Tao
    Yin, Xianggen
    Liu, Feng
    Energy Reports, 2022,
  • [27] The ground-fault circuit interrupter and its utility in the chemical laboratory.
    Li, RWC
    Gruber, J
    de Lucca, MA
    Lisboa, AS
    QUIMICA NOVA, 1998, 21 (03): : 341 - 342
  • [28] Evaluation of the Applicability of IFRA for Short Circuit Fault Detection of Stator Windings in Synchronous Machines
    Yu, Yueqiang
    Zhao, Zhongyong
    Chen, Yu
    Wu, Hanzhi
    Tang, Chao
    Gu, Wenwen
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [29] New On-line Excitation-System Ground-Fault Location Method Tested in a 106 MVA Synchronous Generator
    Blanquez, F. R.
    Pardo, M.
    Platero, C. A.
    Rebollo, E.
    Blazquez, F.
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 1908 - 1914
  • [30] Verification of a Synchronous Machine Model for Stator Ground Fault Simulation Through Measurements in a Large Generator
    Bermejo, A.
    Platero, C. A.
    Blazquez, F.
    Blanquez, F.
    Rebollo, E.
    2014 2ND INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE, MODELLING AND SIMULATION, 2014, : 240 - 245