Evaluation of the Grounding Circuit Measurements for Stator Ground-Fault Location of Synchronous Generators

被引:0
|
作者
Blanquez, F. R. [1 ]
Rebollo, E. [1 ]
Platero, C. A. [1 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, E-28040 Madrid, Spain
关键词
Stator ground fault; fault location; generator protection;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Locating stator-winding ground faults accurately is a very difficult task. In this paper the grounding circuit measurements are evaluated in order to obtain information about the stator ground-fault location in synchronous generators. In power generators grounded through a high impedance, the relation between the neutral voltage and the phase voltage provide a first estimation of the fault location. The location error by using this ratio depends on the fault resistance and the value of the capacitance to ground of the stator winding. However, the error added by ignoring the value of the fault resistance is the most relevant term. This location estimation and the location error have been evaluated through the data of a real synchronous machine.
引用
收藏
页码:229 / 233
页数:5
相关论文
共 50 条
  • [41] MV generator low-resistance grounding and stator ground fault damage
    Wu, A
    Tang, YS
    Finney, D
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (02) : 672 - 679
  • [42] MV generator low-resistance grounding and stator ground fault damage
    Wu, A
    Tang, YS
    Finney, D
    CONFERENCE RECORD OF THE 2004 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4: COVERING THEORY TO PRACTICE, 2004, : 2445 - 2452
  • [43] MV generator low-resistance grounding and stator ground fault damage
    Wu, A
    Tang, YS
    Finney, D
    CONFERENCE RECORD OF THE 2003 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 2003, : 82 - 97
  • [44] Vibration Signature Analysis of Stator Winding Fault Diagnosis in Brushless Synchronous Generators
    Nadarajan, Sivakumar
    Wang, Rui
    Gupta, Amit Kumar
    Panda, Sanjib Kumar
    2015 IEEE INTERNATIONAL TRANSPORTATION ELECTRIFICATION CONFERENCE (ITEC), 2015,
  • [45] Ground-fault protection of four-pole generators with two parallel branches in phase winding
    Zielichowski, Mieczyslaw
    Szlezak, Tomasz
    IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (02) : 813 - 819
  • [47] EXPANDER MATCHES GROUND-FAULT INTERRUPT CIRCUIT TO UL TRIP-TIME SPECIFICATIONS
    GROSS, TAO
    ELECTRONIC DESIGN, 1977, 25 (03) : 70 - &
  • [48] Stator grounding fault location method based on distribution characteristics of fundamental wave potential
    Yin L.
    Gui L.
    Zhang Q.
    Chen J.
    Wang X.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (07): : 141 - 146
  • [49] Novel On-Line Field ground-fault Location Method for Alternators with Static Excitation
    Jamdade, K. B.
    Thorat, A. R.
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 1065 - 1069
  • [50] Impact of Stator Interturn Short Circuit Position on End Winding Vibration in Synchronous Generators
    He, Yu-Ling
    Xu, Ming-Xing
    Zhang, Wen
    Wang, Xiao-Long
    Lu, Peng
    Gerada, Chris
    Gerada, David
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (02) : 713 - 724