On-line stator ground-fault location method for synchronous generators based on 100% stator low-frequency injection protection

被引:19
|
作者
Blanquez, F. R. [1 ]
Platero, C. A. [1 ]
Rebollo, E. [1 ]
Blazquez, F. [1 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, E-28040 Madrid, Spain
关键词
Fault detection; Fault location; Generators; Protection; Rotating machines; Power system protection; UNIT-CONNECTED GENERATOR; VOLTAGES; SYSTEM;
D O I
10.1016/j.epsr.2015.03.017
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Locating stator-winding ground faults accurately is a very difficult task, especially in high-impedance grounded generators. Through the conventional measurements of power plants, obtaining the precise location of these defects in on-line operating conditions is not possible, because the fault resistance is unknown. This paper presents a general algorithm for locating stator-winding ground faults in on-line operating conditions, based on the measurements provided by the 100% ground-fault low-frequency injection protection, and other available measurements. Some simplifications are applied to the general algorithm, and a simplified method is also presented for generators with especially low capacitance-to-ground, whose implementation in modern protective relays is more simple. The location through the general algorithm, and the simplified algorithms, has been validated by simulation and experimental tests, for several fault resistance values at different points of the stator winding. These algorithms assure an acceptable accuracy for a wide range of fault resistance values and locations, without the need of any additional equipment. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 44
页数:11
相关论文
共 50 条
  • [1] Evaluation of the stator ground-fault protection for synchronous generators by means of the subharmonic injection method
    Giraldo, Luis C.
    Mora-Florez, Juan J.
    Olguin, Gabriel
    INGENIERIA Y COMPETITIVIDAD, 2008, 10 (01): : 21 - 30
  • [2] Applying 100% Stator Ground Fault Protection by Low Frequency Injection for Generators
    Turner, Steve
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1152 - 1157
  • [3] Evaluation of the Grounding Circuit Measurements for Stator Ground-Fault Location of Synchronous Generators
    Blanquez, F. R.
    Rebollo, E.
    Platero, C. A.
    2013 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2013, : 229 - 233
  • [4] Adaptive 100% Stator Ground Fault Protection Based on Subharmonic Injection Method
    Safari-Shad, Nader
    Franklin, Russ
    2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 2151 - 2157
  • [5] Optimization of stator ground fault protection for synchronous generators based on negative sequence current supervision
    Faria, Bruno dos Santos
    Villegas Guerrero, Carlos Alberto
    da Silveira, Paulo Marcio
    de Paiva, Rafael Bertolini
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [6] New On-line Rotor Ground Fault Location Method for Brushless Synchronous Generators
    Pardo, M. A.
    Mahtani, K.
    Platero, C. A.
    Sanchez-Fernandez, J. A.
    2021 IEEE 13TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2021, : 140 - 145
  • [7] Adaptive 100% Injection-Based Generator Stator Ground Fault Protection With Real-Time Fault Location Capability
    Safari-Shad, Nader
    Franklin, Russ
    Negahdari, Amir
    Toliyat, Hamid A.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (05) : 2364 - 2372
  • [8] Experimental Verification of a Novel Adaptive Stator Ground Fault Protection Scheme for Synchronous Generators
    Al Jaafari, Khaled
    Negandari, Amir
    Toliyat, Hamid A.
    Safari-Shad, Nader
    Franklin, Russ
    2016 XXII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2016, : 2237 - 2243
  • [9] Improvement of the third harmonic based stator ground fault protection for high resistance grounded synchronous generators
    Ruiz-Mondragon, Byron
    Mora-Florez, Juan
    Perez-Londono, Sandra
    REVISTA FACULTAD DE INGENIERIA-UNIVERSIDAD DE ANTIOQUIA, 2010, (52): : 215 - 225
  • [10] Detection and location of a ground-fault in the excitation circuit of a 106 MVA synchronous generator by a new on-line method
    Pardo, M.
    Blanquez, F. R.
    Platero, C. A.
    Rebollo, E.
    Blazquez, F.
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 140 : 303 - 311