An epistemic indoor air quality assessment protocol for air-conditioned offices

被引:15
|
作者
Hui, P. S. [1 ]
Wong, L. T. [1 ]
Mui, K. W. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
IAQ; epistemic assessment; CO2; measurements; air-conditioned offices;
D O I
10.1177/1420326X07076503
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Long-term measurement could be the best approach to determine the average pollutant concentration of an indoor environment for decisions on mitigation measures. This approach requires considerable measurement effort for accurate results and hence indoor air quality (IAQ) assessment methods that need less effort have been cleveloped.This study proposes an epistemic approach for assessing an acceptable office IAQ against certain indoor air pollutant exposure limits. Together with the prior understanding of failure rates of IAQ determined from a number of extensive survey studies, a sample test result of pollutant levels and the uncertainties of different sampling schemes, the probability of satisfactory IAQ for an assessed air-conditioned office could be quantified. In particular, assessment of an acceptable IAQ for some air-conditioned offices in Hong Kong was demonstrated by taking CO2 as an example pollutant. Accuracy of the failure rates was improved by the application of sampling correction factors and Bayesian statistics. The probabilities of an acceptable office IAQ were evaluated against a CO2 level limit. This approach would be useful for IAQ assessment in some air-conditioned offices.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [41] Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area
    Jain, Supreme
    Garg, Divyam
    Goel, Anubha
    INDOOR ENVIRONMENTAL QUALITY, ACIEQ, 2020, 60 : 1 - 8
  • [42] Sampling strategies of indoor air quality assessment for offices
    Hui, P.
    Wong, L.
    Mui, K.
    FACILITIES, 2007, 25 (5-6) : 179 - +
  • [43] Microbial Air Quality in Air-conditioned Passenger Cars
    Golofit-Szymczak, Malgorzata
    Stobnicka-Kupiec, Agata
    ROCZNIK OCHRONA SRODOWISKA, 2018, 20 : 1564 - 1582
  • [44] Development and application of an indoor air quality audit to an air-conditioned tertiary institutional building in the tropics
    Cheong, KWD
    Lau, HYT
    BUILDING AND ENVIRONMENT, 2003, 38 (04) : 605 - 616
  • [45] FIELD STUDY OF AIR QUALITY IN AIR-CONDITIONED SPACES
    SWANTON, JR
    ASHRAE JOURNAL, 1971, 13 (01): : 55 - &
  • [46] Indoor air quality comparison of two air-conditioned zones served by the same air-handling unit
    Tham, KW
    Sekhar, SC
    Cheong, D
    BUILDING AND ENVIRONMENT, 2002, 37 (10) : 947 - 960
  • [47] A method of assessing the acceptability of noise levels in air-conditioned offices
    Mui, K. W.
    Wong, L. T.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2006, 27 (03): : 249 - 254
  • [48] Formaldehyde exposure risk in air-conditioned offices of Hong Kong
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    Chan, W. Y.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2009, 30 (04): : 279 - 286
  • [49] DISINFECTING AIR-CONDITIONED AIR
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1962, (5288): : 1357 - +
  • [50] Survey of unsatisfactory levels of airborne bacteria in air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    Law, K. Y.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 130 - 138