An epistemic indoor air quality assessment protocol for air-conditioned offices

被引:15
|
作者
Hui, P. S. [1 ]
Wong, L. T. [1 ]
Mui, K. W. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
IAQ; epistemic assessment; CO2; measurements; air-conditioned offices;
D O I
10.1177/1420326X07076503
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Long-term measurement could be the best approach to determine the average pollutant concentration of an indoor environment for decisions on mitigation measures. This approach requires considerable measurement effort for accurate results and hence indoor air quality (IAQ) assessment methods that need less effort have been cleveloped.This study proposes an epistemic approach for assessing an acceptable office IAQ against certain indoor air pollutant exposure limits. Together with the prior understanding of failure rates of IAQ determined from a number of extensive survey studies, a sample test result of pollutant levels and the uncertainties of different sampling schemes, the probability of satisfactory IAQ for an assessed air-conditioned office could be quantified. In particular, assessment of an acceptable IAQ for some air-conditioned offices in Hong Kong was demonstrated by taking CO2 as an example pollutant. Accuracy of the failure rates was improved by the application of sampling correction factors and Bayesian statistics. The probabilities of an acceptable office IAQ were evaluated against a CO2 level limit. This approach would be useful for IAQ assessment in some air-conditioned offices.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 50 条
  • [21] Air Quality Assessment for the Microenvironment in Air-conditioned Passenger Trains
    Cai Wei
    Wang Danjun
    Yu Xubo
    EBM 2010: INTERNATIONAL CONFERENCE ON ENGINEERING AND BUSINESS MANAGEMENT, VOLS 1-8, 2010, : 3601 - 3604
  • [22] Energy impact of indoor environmental policy for air-conditioned offices of Hong Kong
    Wong, L. T.
    Mui, K. W.
    Shi, K. L.
    ENERGY POLICY, 2008, 36 (02) : 714 - 721
  • [23] The correlation with indoor environment parameters and current feeling of employees in air-conditioned offices
    Butala, V
    Muhic, S
    Molan, M
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1983 - 1990
  • [24] Development and application of an indoor air quality audit to an air-conditioned building in Singapore
    Cheong, KW
    Chong, KY
    BUILDING AND ENVIRONMENT, 2001, 36 (02) : 181 - 188
  • [25] Indoor air quality and energy performance of air-conditioned office buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, KW
    INDOOR AIR, 2003, 13 (04) : 315 - 331
  • [26] Indoor air quality and ventilation measurements in nine air-conditioned buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 715 - 722
  • [27] Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality
    Prasad, RK
    Uma, R
    Kansal, A
    Gupta, S
    Kumar, P
    Saksena, S
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (06) : 334 - 339
  • [28] Feasibility study of an indoor air quality measurement protocol on 12 parameters in mechanically ventilated and air-conditioned buildings
    Chao, CY
    Chan, GY
    Ho, L
    INDOOR AND BUILT ENVIRONMENT, 2001, 10 (01) : 3 - 19
  • [29] An Assessment of Airborne Fungi Exposure Risk Level in Air-conditioned Offices
    Wong, L. T.
    Chan, W. Y.
    Mui, K. W.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2009, 18 (06) : 553 - 561
  • [30] Indoor air pollution in Air-Conditioned bus and non-Air-Conditioned bus
    Husna, I. E.
    Unzilatirrizqi, Y. E. R. D.
    Sarifuddin
    Wijinurhayati, A. A.
    2ND INTERNATIONAL CONFERENCE ON ENVIRONMENT, SUSTAINABILITY ISSUES, AND COMMUNITY DEVELOPMENT, 2021, 623