Triple channel analysis of Gafchromic EBT3 irradiated with clinical carbon-ion beams

被引:7
|
作者
Holm, Kim Marina [1 ,2 ,3 ,4 ]
Yukihara, Eduardo G. [5 ]
Ahmed, Md Foiez [6 ]
Greilich, Steffen [2 ,3 ]
Jaekel, Oliver [2 ,3 ,7 ]
机构
[1] Phys Tech Bundesanstalt PTB, Dept Dosimetry Radiat Therapy & Diagnost Radiol, Bundesallee 100, D-38116 Braunschweig, Germany
[2] German Canc Res Ctr, Dept Med Phys Radiat Oncol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[3] Heidelberg Inst Radiat Oncol HIRO, Heidelberg, Germany
[4] Heidelberg Univ, Dept Phys & Astron, Neuenheimer Feld 226, D-69120 Heidelberg, Germany
[5] Paul Scherrer Inst, Dept Radiat Safety & Secur, Forschungsstr 111, CH-5232 Villigen, Switzerland
[6] Sun Nucl Corp, 3275 Suntree Blvd, Melbourne, FL 32940 USA
[7] Univ Hosp Heidelberg, Heidelberg Ion Beam Therapy Ctr HIT, Neuenheimer Feld 450, D-69120 Heidelberg, Germany
关键词
Triple channel analysis; Gafchromic EBT3; Carbon-ion beams; RADIOCHROMIC FILM DOSIMETRY; PROTON;
D O I
10.1016/j.ejmp.2021.06.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Self-developing radiochromic film is widely used in radiotherapy QA procedures. To compensate for typical film inhomogeneities, the triple channel analysis method is commonly used for photon-irradiated film. We investigated the applicability of this method for GafchromicTMEBT3 (Ashland) film irradiated with a clinically used carbon-ion beam. Calibration curves were taken from EBT3 film specimens irradiated with monoenergetic carbon-ion beams of different doses. Measurements of the lateral field shape and homogeneity were performed in the middle of a passively modulated spread-out Bragg peak and compared to simultaneous characterization by means of a 2D ionization chamber array. Additional measurements to investigate the applicability of EBT3 for quality assurance (QA) measurement in carbon-ion beams were performed. The triple-channel analysis reduced the relative standard deviation of the doses in a uniform carbon ion field by 30% (from 1.9% to 1.3%) and reduced the maximum deviation by almost a factor of 3 (from 28.6% to 9.8%), demonstrating the elimination of film artifacts. The corrected film signal showed considerably improved image quality and quantitative agreement with the ionization chamber data, thus providing a clear rationale for the usage of the triple channel analysis in carbon-beam QA.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 50 条
  • [1] EXPERIMENTAL EVALUATION OF DOSIMETRIC CHARACTERIZATION OF GAFCHROMIC EBT3 AND EBT-XD FILMS FOR CLINICAL CARBON ION BEAMS
    Yonai, Shunsuke
    Arai, Chinatsu
    Shimoyama, Kaoru
    Fournier-Bidoz, Nathalie
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 314 - 318
  • [2] Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams
    Reinhardt, S.
    Hillbrand, M.
    Wilkens, J. J.
    Assmann, W.
    MEDICAL PHYSICS, 2012, 39 (08) : 5257 - 5262
  • [3] Evaluation of the Energy Dependence of Gafchromic EBT3 Film for Electron Beams
    Inoue, T.
    Sugimoto, S.
    Fukata, K.
    Kurokawa, C.
    Ozawa, S.
    Sasai, K.
    MEDICAL PHYSICS, 2012, 39 (06) : 3735 - 3736
  • [4] Ion beam dosimetry using Gafchromic EBT3 film
    Hassan, M. G.
    El-Saftawy, A. A.
    Soliman, B. A.
    Abdelrahman, M. M.
    Abdelmageed, K. E.
    Hassouba, M. A.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (06):
  • [5] Validation of XiO's eMC Module Using Gafchromic EBT3 Films and Triple Channel Dosimetry
    Archambault, L. K.
    Munger, P.
    Nicol, S.
    Brunet-Benkhoucha, M.
    MEDICAL PHYSICS, 2012, 39 (07) : 4619 - 4619
  • [6] Beam quality and dose rate dependency of Gafchromic EBT3 film irradiated with therapeutic megavolt photon beams
    Sharma, Megha
    Singh, Ranjit
    Robert, N.
    Trivedi, G.
    Tomar, P.
    Oinam, A. S.
    RADIATION MEASUREMENTS, 2021, 146
  • [7] Study on Corrections of Dose Images Obtained with Gafchromic EBT3 Films for Measurements in Phantoms Irradiated with Proton Beams
    Gambarini, G.
    Massari, E.
    Regazzoni, V.
    Giove, D.
    Mirandola, A.
    Ciocca, M.
    2015 4TH INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2015,
  • [8] Dose-response of EBT3 radiochromic films to proton and carbon ion clinical beams
    Castriconi, Roberta
    Ciocca, Mario
    Mirandola, Alfredo
    Sini, Carla
    Broggi, Sara
    Schwarz, Marco
    Fracchiolla, Francesco
    Martisikova, Maria
    Arico, Giulia
    Mettivier, Giovanni
    Russo, Paolo
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02): : 377 - 393
  • [9] Comparison of the Absorption Spectra of the EBT-XD and EBT3 Films Irradiated with Clinical Radiotherapy Beams
    Leon, Y.
    Mulrow, D.
    Khan, R.
    Darafsheh, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E621 - E621
  • [10] Dosimetric Characteristics of Gafchromic EBT3 Films for Megavoltage Photon and Proton Beams
    Hayashi, N.
    Kato, H.
    Yada, R.
    Matsunaga, T.
    Ehara, I.
    Adachi, Y.
    MEDICAL PHYSICS, 2012, 39 (06) : 3732 - 3732