Ion beam dosimetry using Gafchromic EBT3 film

被引:0
|
作者
Hassan, M. G. [1 ]
El-Saftawy, A. A. [1 ]
Soliman, B. A. [1 ]
Abdelrahman, M. M. [1 ]
Abdelmageed, K. E. [2 ]
Hassouba, M. A. [2 ]
机构
[1] Egyptian Atom Energy Author, Nucl Res Ctr, Accelerators & Ion Sources Dept, PO 13759, Cairo, Egypt
[2] Benha Univ, Fac Sci, Phys Dept, Banha, Egypt
来源
关键词
Ion beam; Peeled EBT3 film; Optical density; Coloration; Blue-phase; Red-phase; FLAT-BED SCANNERS; RADIATION-THERAPY; LANGMUIR-BLODGETT; N) POLYCARBONATE; REGISTRATION; ENERGY; POLYMERS; MAKROFOL; CR-39; PHOTOPOLYMERIZATION;
D O I
10.1007/s00339-024-07607-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The objective of this study was to investigate the use of EBT3 film, specifically the active layer, for monitoring low-energy ion beams. The film's wettability was enhanced, and its surface free energy increased by 200% after irradiation, as determined by the contact angle technique. SEM analysis showed that the surface of the film became rougher, with a needle-like structure, and increased from 80 nm for the pristine sample to 116 nm for the sample exposed to the highest fluence. XRD analysis revealed an increase in crystallite dimension and a decrease in crystallinity. ATR-FTIR analysis demonstrated that the modified film is sensitive to low-energy ion beams, with certain bands showing significant changes that can be controlled by adjusting the ion fluence. These changes affect the color properties of the EBT3 film, which can be used to monitor the ion beam. The visible spectrum exhibited two distinct colors: blue at 648 nm and red at 596 nm. The blue-to-red ratio was calibrated based on the applied fluence using a polynomial function. The film's net optical density was separately analyzed for each color, with the blue color being dominant. However, the red color accurately calibrated the film's response to low-energy ion beams with a usable fluence of up to 1 x 1017 ion/cm2. In conclusion, low-energy ion beams caused significant structural and optical changes in the active layer of EBT3 films, which can be controlled and customized for monitoring ion beams.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] External Photon Beam Dosimetry for Linac QA Using Gafchromic EBT3 Film
    Khan, I.
    Tahir, B.
    Rafique, M.
    Iqbal, T.
    Zulfiqar, S.
    Zahoor, A.
    Rehman, J.
    Iqbal, K.
    Chow, J.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E309 - E309
  • [2] Raman scattering for dosimetry using GAFCHROMIC EBT3 radiochromic dosimetry film
    Talarico, Olga S.
    Krylova, Tatyana A.
    Melnik, Nikolay N.
    [J]. MEDICAL PHYSICS, 2019, 46 (04) : 1883 - 1887
  • [3] A characterisation of EBT3 Gafchromic film for relative and absolute dosimetry
    Billas, I.
    Bouchard, H.
    Subiel, A.
    Silvestre, I.
    Duane, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S414 - S414
  • [4] Precise EBT3 Gafchromic film dosimetry for Grid therapy
    Gholami, Somayeh
    Nedaie, Hassan Ali
    Meigooni, Ali S.
    [J]. RADIATION MEASUREMENTS, 2019, 121 : 69 - 76
  • [5] CALIBRATION OF GAFCHROMIC EBT3 FILM FOR DOSIMETRY OF SCANNING PROTON PENCIL BEAM (PBS)
    Krzempek, D.
    Mianowska, G.
    Bassler, N.
    Stolarczyk, L.
    Kopec, R.
    Sas-Korczynska, B.
    Olko, P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 324 - 328
  • [6] Extrapolation Techniques for Small Field Dosimetry Using Gafchromic EBT3 Film
    Morales, J.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3596 - 3596
  • [7] Multichannel absolute film dosimetry for EBT3 GafChromic films
    Ventura, T.
    Lopes, M. C.
    Ferreira, B. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S169 - S169
  • [8] In vivo Dosimetry for Dose Verification of Total Skin Electron Beam Therapy Using Gafchromic® EBT3 Film Dosimetry
    Baba, Misba Hamid
    Singh, Benoy Kumar
    Wani, Shaqul Qamar
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (04) : 362 - 366
  • [9] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Moylan, Rebecca
    Aland, Trent
    Kairn, Tanya
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (03) : 331 - 337
  • [10] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Rebecca Moylan
    Trent Aland
    Tanya Kairn
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 331 - 337