Triple channel analysis of Gafchromic EBT3 irradiated with clinical carbon-ion beams

被引:7
|
作者
Holm, Kim Marina [1 ,2 ,3 ,4 ]
Yukihara, Eduardo G. [5 ]
Ahmed, Md Foiez [6 ]
Greilich, Steffen [2 ,3 ]
Jaekel, Oliver [2 ,3 ,7 ]
机构
[1] Phys Tech Bundesanstalt PTB, Dept Dosimetry Radiat Therapy & Diagnost Radiol, Bundesallee 100, D-38116 Braunschweig, Germany
[2] German Canc Res Ctr, Dept Med Phys Radiat Oncol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[3] Heidelberg Inst Radiat Oncol HIRO, Heidelberg, Germany
[4] Heidelberg Univ, Dept Phys & Astron, Neuenheimer Feld 226, D-69120 Heidelberg, Germany
[5] Paul Scherrer Inst, Dept Radiat Safety & Secur, Forschungsstr 111, CH-5232 Villigen, Switzerland
[6] Sun Nucl Corp, 3275 Suntree Blvd, Melbourne, FL 32940 USA
[7] Univ Hosp Heidelberg, Heidelberg Ion Beam Therapy Ctr HIT, Neuenheimer Feld 450, D-69120 Heidelberg, Germany
关键词
Triple channel analysis; Gafchromic EBT3; Carbon-ion beams; RADIOCHROMIC FILM DOSIMETRY; PROTON;
D O I
10.1016/j.ejmp.2021.06.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Self-developing radiochromic film is widely used in radiotherapy QA procedures. To compensate for typical film inhomogeneities, the triple channel analysis method is commonly used for photon-irradiated film. We investigated the applicability of this method for GafchromicTMEBT3 (Ashland) film irradiated with a clinically used carbon-ion beam. Calibration curves were taken from EBT3 film specimens irradiated with monoenergetic carbon-ion beams of different doses. Measurements of the lateral field shape and homogeneity were performed in the middle of a passively modulated spread-out Bragg peak and compared to simultaneous characterization by means of a 2D ionization chamber array. Additional measurements to investigate the applicability of EBT3 for quality assurance (QA) measurement in carbon-ion beams were performed. The triple-channel analysis reduced the relative standard deviation of the doses in a uniform carbon ion field by 30% (from 1.9% to 1.3%) and reduced the maximum deviation by almost a factor of 3 (from 28.6% to 9.8%), demonstrating the elimination of film artifacts. The corrected film signal showed considerably improved image quality and quantitative agreement with the ionization chamber data, thus providing a clear rationale for the usage of the triple channel analysis in carbon-beam QA.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 50 条
  • [41] The Effect of Thermoplatic Mask to the Surface Dose in Sterotactic Brain Treatments with Flattening Filter Free Beams with EBT3 Gafchromic Film and OSL Dosimeter
    Yilidir, G.
    Acar, H.
    Kucuk, N.
    Kucukmorkoc, E.
    Doyuran, M.
    Caglar, M.
    Altinok, A.
    Cebe, M.
    Mabhouti, H.
    Caglar, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3505 - 3505
  • [42] Comparative analysis of the immune responses in cancer cells irradiated with X-ray, proton and carbon-ion beams
    Du, Junyan
    Kageyama, Shun-Ichiro
    Hirata, Hidenari
    Motegi, Atsushi
    Nakamura, Masaki
    Hirano, Yasuhiro
    Okumura, Masayuki
    Yamashita, Riu
    Tsuchihara, Katsuya
    Hojo, Hidehiro
    Hirayama, Ryoichi
    Akimoto, Tetsuo
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2021, 585 : 55 - 60
  • [43] Genetic polymorphisms in mutagenesis progeny of Arabidopsis thaliana irradiated by carbon-ion beams and γ-rays irradiations
    Chen, Xia
    Feng, Hui
    Du, Yan
    Luo, Shanwei
    Li, Wenjian
    Yu, Lixia
    Feng, Zhuo
    Cui, Tao
    Zhou, Libin
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2020, 96 (02) : 267 - 275
  • [44] Acquisition of Small Field Electron Dosimetry Data using Ion Chamber & Gafchromic® EBT3 Film and Development of GUI for Treatment Parameters Calculation
    Ali, Faisal
    Jangda, Abdul Qadir
    Hussain, Amjad
    Ahmed, Shahbaz
    Rehman, Shakeel Ur
    2016 INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2016,
  • [45] Spectral analysis of the EBT3 radiochromic film irradiated with 6 MV X-ray radiation
    Leon-Marroquin, Elsa Y.
    Camacho-Lopez, Miguel A.
    Garcia-Garduno, Olivia A.
    Alfredo Herrera-Gonzalez, J.
    Eduardo Villarreal-Barajas, J.
    Gutierrez-Fuentes, Ruben
    Contreras-Bulnes, Rosalia
    RADIATION MEASUREMENTS, 2016, 89 : 82 - 88
  • [46] Development of a procedure for quenching-effect correction in images of absorbed dose from protons or carbon ions acquired with Gafchromic EBT3 films
    Gambarini, G.
    Bettega, D.
    Camoni, G.
    Barzon, G.
    Bettinelli, L.
    Giove, D.
    Carrara, M.
    Mirandola, A.
    Ciocca, M.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 155 : 138 - 145
  • [47] Changes in scanning orientation effects of Gafchromic EBT-3 film irradiated with ultra-high dose rate proton beams
    Yasuda, Hiroshi
    Bantan, Hassna
    Umezawa, Masumi
    Yamada, Masashi
    Yogo, Katsunori
    Toshito, Toshiyuki
    DISCOVER APPLIED SCIENCES, 2025, 7 (01)
  • [48] Chromosome breakage and cell lethality in human hepatoma cells irradiated with X rays and carbon-ion beams
    Space Particle Radiat. Sci. Res. G., Natl. Inst. of Radiological Sciences, 9-1, Anagawa-4-chome, Inage-ku, Chiba-shi, Chiba 263-8555, Japan
    不详
    J. Rad. Res., 2 (125-133):
  • [49] Chromosome breakage and cell lethality in human hepatoma cells irradiated with X rays and carbon-ion beams
    Ofuchi, T
    Suzuki, M
    Kase, Y
    Ando, K
    Isono, K
    Ochiai, T
    JOURNAL OF RADIATION RESEARCH, 1999, 40 (02) : 125 - 133
  • [50] ESR spin trapping of hydroxyl radicals in aqueous solution irradiated with high-LET carbon-ion beams
    Moritake, T
    Tsuboi, K
    Anzai, K
    Ozawa, T
    Ando, K
    Nose, T
    RADIATION RESEARCH, 2003, 159 (05) : 670 - 675