Triple channel analysis of Gafchromic EBT3 irradiated with clinical carbon-ion beams

被引:7
|
作者
Holm, Kim Marina [1 ,2 ,3 ,4 ]
Yukihara, Eduardo G. [5 ]
Ahmed, Md Foiez [6 ]
Greilich, Steffen [2 ,3 ]
Jaekel, Oliver [2 ,3 ,7 ]
机构
[1] Phys Tech Bundesanstalt PTB, Dept Dosimetry Radiat Therapy & Diagnost Radiol, Bundesallee 100, D-38116 Braunschweig, Germany
[2] German Canc Res Ctr, Dept Med Phys Radiat Oncol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[3] Heidelberg Inst Radiat Oncol HIRO, Heidelberg, Germany
[4] Heidelberg Univ, Dept Phys & Astron, Neuenheimer Feld 226, D-69120 Heidelberg, Germany
[5] Paul Scherrer Inst, Dept Radiat Safety & Secur, Forschungsstr 111, CH-5232 Villigen, Switzerland
[6] Sun Nucl Corp, 3275 Suntree Blvd, Melbourne, FL 32940 USA
[7] Univ Hosp Heidelberg, Heidelberg Ion Beam Therapy Ctr HIT, Neuenheimer Feld 450, D-69120 Heidelberg, Germany
关键词
Triple channel analysis; Gafchromic EBT3; Carbon-ion beams; RADIOCHROMIC FILM DOSIMETRY; PROTON;
D O I
10.1016/j.ejmp.2021.06.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Self-developing radiochromic film is widely used in radiotherapy QA procedures. To compensate for typical film inhomogeneities, the triple channel analysis method is commonly used for photon-irradiated film. We investigated the applicability of this method for GafchromicTMEBT3 (Ashland) film irradiated with a clinically used carbon-ion beam. Calibration curves were taken from EBT3 film specimens irradiated with monoenergetic carbon-ion beams of different doses. Measurements of the lateral field shape and homogeneity were performed in the middle of a passively modulated spread-out Bragg peak and compared to simultaneous characterization by means of a 2D ionization chamber array. Additional measurements to investigate the applicability of EBT3 for quality assurance (QA) measurement in carbon-ion beams were performed. The triple-channel analysis reduced the relative standard deviation of the doses in a uniform carbon ion field by 30% (from 1.9% to 1.3%) and reduced the maximum deviation by almost a factor of 3 (from 28.6% to 9.8%), demonstrating the elimination of film artifacts. The corrected film signal showed considerably improved image quality and quantitative agreement with the ionization chamber data, thus providing a clear rationale for the usage of the triple channel analysis in carbon-beam QA.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 50 条
  • [11] Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams
    Sorriaux, J.
    Kacperek, A.
    Rossomme, S.
    Lee, J. A.
    Bertrand, D.
    Vynckier, S.
    Sterpin, E.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (06): : 599 - 606
  • [12] Dosimetric properties of Gafchromic® EBT films in medical carbon ion beams
    Martisikova, Maria
    Jaekel, Oliver
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18): : 5557 - 5567
  • [13] Investigation of Gafchromic EBT3 Film Energy Dependence Using Proton, Photon, and Electron Beams
    Ferreira, C.
    Schnell, E.
    Ahmad, S.
    Herman, T. De La Fuente
    MEDICAL PHYSICS, 2016, 43 (06) : 3403 - 3403
  • [14] Spectral Analysis of the EBT3 Radiochromic Films for Clinical Photon and Electron Beams
    Leon, Y.
    Mulrow, D.
    Khan, R.
    Darafsheh, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E311 - E311
  • [15] Spectral analysis of the EBT3 radiochromic films for clinical photon and electron beams
    Leon-Marroquin, Elsa Y.
    Mulrow, Daniel J.
    Khan, Rao
    Darafsheh, Arash
    MEDICAL PHYSICS, 2019, 46 (02) : 973 - 982
  • [16] Temperature dependent dose readout of Gafchromic EBT3 and EBT-XD film and clinical relevance in SRT
    Buchauer, K.
    Plasswilm, L.
    Schiefer, J.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S807 - S808
  • [17] Evaluation of lens dose from anterior electron beams: comparison of Pinnacle and Gafchromic EBT3 film
    Sonier, Marcus
    Wronski, Matt
    Yeboah, Collins
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 304 - 314
  • [18] Evaluation of lens dose from anterior electron beams: comparison of Pinnacle and Gafchromic EBT3 film
    Sonier, M.
    Wronski, M.
    Yeboah, C.
    MEDICAL PHYSICS, 2014, 41 (08) : 12 - 12
  • [19] Clinical Comparison of Gafchromic EBT-XD Film to Gafchromic EBT3 Film When Utilized as An Absolute Dose Verification Method in Stereotactic Radiotherapy
    Goodman, R.
    Murphy, T.
    Siergiej, D.
    Schroeder, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E280 - E280
  • [20] Analysis of the EBT3 Gafchromic film irradiated with 6 MV photons and 6 MeV electrons using reflective mode scanners
    Farah, Nicolas
    Francis, Ziad
    Abboud, Marie
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (06): : 708 - 712