Optic Nerve Sheath Diameter Detects Intracranial Hypertension in Acute Malignant Middle Cerebral Artery Infarction

被引:11
|
作者
Oliveira, Breno Douglas Dantas [1 ,2 ]
Lima, Fabricio Oliveira [3 ]
Homem, Hellen do Carm [3 ]
Figueiredo, Alice Albuquerque [2 ]
Batista Freire, Vitoria Maria [4 ]
Maia Carvalho, Fernanda Martins [1 ,3 ]
机构
[1] Univ Fortaleza UNIFOR, Med Sci Postgrad Program, BR-60811905 Fortaleza, Ceara, Brazil
[2] Univ Fortaleza UNIFOR, Med Program, BR-60811905 Fortaleza, Ceara, Brazil
[3] Hosp Geral Fortaleza, Neurol Dept, BR-60150160 Fortaleza, Ceara, Brazil
[4] Ctr Univ Christus UNICHRISTUS, Med Program, BR-60190180 Fortaleza, Ceara, Brazil
来源
关键词
Key Words; Optic nerve; Intracranial hypertension; Ultrasound imaging; Middle cerebral artery stroke; Decompressive craniectomy; TERRITORY INFARCTION; PRESSURE;
D O I
10.1016/j.jstrokecerebrovasdis.2021.106276
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: To evaluate optic nerve sheath diameter in the acute phase of patients with malignant ischemic middle cerebral artery stroke submitted or not to decompressive craniectomy surgery. Materials and Methods: Forty patients participated in the study and were evaluated bilaterally by ultrasound on admission and at 24h, 48h and 72 h after admission. Optic nerve sheath diameter values were correlated with tomographic and/or clinical criteria compatible with severe intracranial hypertension. Results: A Receiver Operating Characteristic curve was drawn for each eye, determining a cut-off value for severe intracranial hypertension in the right eye of 5.4 mm (sensitivity: 62%; specificity: 100%; AUC: 0.82) and in the left eye 5.4 mm (sensitivity: 76%; specificity: 84%; AUC: 0.77). In patients undergoing craniectomy, there was a decrease in the mean value of 1.04mm in the right eye (pre: 5.84 +/- 0.47 mm; post: 4.80 +/- 0.84 mm; p = 0.001), while in the left, it decreased around 0.86mm (pre: 5.59 +/- 0.69 mm; post: 4.73 +/- 0.74 mm; p = 0.003). Patients with fatal outcome showed a persistent high mean ocular nerve sheath diameter. Conclusions: Monitoring optic nerve sheath by ultrasound can be considered a reliable method for identifying severe intracranial hypertension in patients with large vessel occlusion, as well as for monitoring patients undergoing craniectomy. Additional studies will be necessary to include this parameter in craniectomy indication in the future.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Bedside Optic Nerve Sheath Diameter Assessment in the Identification of Increased Intracranial Pressure in Suspected Idiopathic Intracranial Hypertension
    Irazuzta, Jose E.
    Brown, Martha E.
    Akhtar, Javed
    PEDIATRIC NEUROLOGY, 2016, 54 : 35 - 38
  • [42] Transorbital sonography and MRI reliability to assess optic nerve sheath diameter in idiopathic intracranial hypertension
    Roemer, Sebastian Niclas
    Friedrich, Erik Bernhard
    Kettner, Michael
    Rauzi, Martina
    Schub, Peter
    Kulikovski, Johann
    Janitschke, Daniel
    Stoegbauer, Jakob
    Lochner, Piergiorgio
    JOURNAL OF NEUROIMAGING, 2023, 33 (03) : 375 - 380
  • [43] The Contribution of Measuring the Optic Nerve Sheath Diameter by using Ultrasonography to the Diagnosis and Monitoring of Intracranial Hypertension
    Kendir, Ozlem Tolu
    Yilmaz, Hayri Levent
    Ozkaya, Ahmet Kagan
    Gokay, Sinem Sari
    Bilen, Sevcan
    JOURNAL OF EMERGENCY MEDICINE CASE REPORTS, 2020, 11 (01): : 21 - 25
  • [44] Effect of bronchoscopy on intracranial hypertension during different regimen of sedation by optic nerve sheath diameter
    Ozsari, Emine
    Demirhan, Abdullah
    NEUROLOGY ASIA, 2021, 26 (04) : 795 - 800
  • [45] Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and its Application to Detect Intracranial Hypertension in Children REPLY
    Fontanel, Liviana
    Pensiero, Stefano
    Ronfani, Luca
    Rosolen, Valentina
    Barbi, Egidio
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 439 - 439
  • [46] High-resolution MRI assessment of optic nerve sheath diameter in adults: optic nerve sheath variation and a new diagnostic tool for intracranial hypertension
    Zheng, Ying-mei
    Hao, Da-peng
    Tang, Guo-zhang
    Zhou, Rui-zhi
    Pang, Jing
    Dong, Cheng
    ACTA RADIOLOGICA, 2021, 62 (10) : 1397 - 1403
  • [47] PREDICTORS OF MALIGNANT MIDDLE CEREBRAL ARTERY INFARCTION IN ACUTE STROKE
    da Silva, A. A.
    Almeida, M. S.
    Oliverira-Filho, J.
    INTENSIVE CARE MEDICINE, 2011, 37 : S251 - S251
  • [48] Response to "Measuring the Optic Nerve Sheath Diameter with Ultrasound in Acute Middle Cerebral Artery Stroke Patients": For Application to Long-Duration Spaceflight (LDSF)
    Mohanadass, Chloe A.
    Church, Lauren E.
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (04):
  • [49] Optic Nerve Sheath Diameter and Acute Mountain Sickness
    Keyes, Linda E.
    Paterson, Ryan
    Boatright, Dowin
    Browne, Vaughn
    Leadbetter, Gig
    Hackett, Peter
    WILDERNESS & ENVIRONMENTAL MEDICINE, 2013, 24 (02) : 105 - 111
  • [50] Optic Nerve Sheath Diameter and Acute Mountain Sickness
    Sikri, Gaurav
    Singh, Krishan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (02) : 455 - 456