Optic Nerve Sheath Diameter Detects Intracranial Hypertension in Acute Malignant Middle Cerebral Artery Infarction

被引:11
|
作者
Oliveira, Breno Douglas Dantas [1 ,2 ]
Lima, Fabricio Oliveira [3 ]
Homem, Hellen do Carm [3 ]
Figueiredo, Alice Albuquerque [2 ]
Batista Freire, Vitoria Maria [4 ]
Maia Carvalho, Fernanda Martins [1 ,3 ]
机构
[1] Univ Fortaleza UNIFOR, Med Sci Postgrad Program, BR-60811905 Fortaleza, Ceara, Brazil
[2] Univ Fortaleza UNIFOR, Med Program, BR-60811905 Fortaleza, Ceara, Brazil
[3] Hosp Geral Fortaleza, Neurol Dept, BR-60150160 Fortaleza, Ceara, Brazil
[4] Ctr Univ Christus UNICHRISTUS, Med Program, BR-60190180 Fortaleza, Ceara, Brazil
来源
关键词
Key Words; Optic nerve; Intracranial hypertension; Ultrasound imaging; Middle cerebral artery stroke; Decompressive craniectomy; TERRITORY INFARCTION; PRESSURE;
D O I
10.1016/j.jstrokecerebrovasdis.2021.106276
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: To evaluate optic nerve sheath diameter in the acute phase of patients with malignant ischemic middle cerebral artery stroke submitted or not to decompressive craniectomy surgery. Materials and Methods: Forty patients participated in the study and were evaluated bilaterally by ultrasound on admission and at 24h, 48h and 72 h after admission. Optic nerve sheath diameter values were correlated with tomographic and/or clinical criteria compatible with severe intracranial hypertension. Results: A Receiver Operating Characteristic curve was drawn for each eye, determining a cut-off value for severe intracranial hypertension in the right eye of 5.4 mm (sensitivity: 62%; specificity: 100%; AUC: 0.82) and in the left eye 5.4 mm (sensitivity: 76%; specificity: 84%; AUC: 0.77). In patients undergoing craniectomy, there was a decrease in the mean value of 1.04mm in the right eye (pre: 5.84 +/- 0.47 mm; post: 4.80 +/- 0.84 mm; p = 0.001), while in the left, it decreased around 0.86mm (pre: 5.59 +/- 0.69 mm; post: 4.73 +/- 0.74 mm; p = 0.003). Patients with fatal outcome showed a persistent high mean ocular nerve sheath diameter. Conclusions: Monitoring optic nerve sheath by ultrasound can be considered a reliable method for identifying severe intracranial hypertension in patients with large vessel occlusion, as well as for monitoring patients undergoing craniectomy. Additional studies will be necessary to include this parameter in craniectomy indication in the future.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and Its Application to Detect Intracranial Hypertension in Children
    Fontanel, Liviana
    Pensiero, Stefano
    Ronfani, Luca
    Rosolen, Valentina
    Barbi, Egidio
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 421 - 428
  • [32] Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and its Application to Detect Intracranial Hypertension in Children
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 438 - 438
  • [33] Evaluating the optic nerve stiffness and optic nerve sheath diameter in idiopathic intracranial hypertension patients after the resolution of papilledema
    Kaya, Fatma Selin
    Bayram, Ersoy
    Inci, Ercan
    NEUROLOGICAL SCIENCES, 2021, 42 (12) : 5165 - 5170
  • [34] Evaluating the optic nerve stiffness and optic nerve sheath diameter in idiopathic intracranial hypertension patients after the resolution of papilledema
    Fatma Selin Kaya
    Ersoy Bayram
    Ercan İnci
    Neurological Sciences, 2021, 42 : 5165 - 5170
  • [35] Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke
    Guo, Yuan
    Chen, Yinjuan
    Shen, Chaoxiong
    Fan, Daofeng
    Hu, Xiaohong
    Duan, Jiaojiao
    Chen, Yangui
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [36] Intracranial hypertension: Ultrasound measurement of the optic nerve sheath
    Vazquez Martinez, Jose Luis
    Hernandez Villarroel, Aiza Carolina
    Tejado Castillo, Maria
    Sanchez Porras, Maria
    ANALES DE PEDIATRIA, 2018, 89 (05): : 318 - 319
  • [37] Ultrasound widening of the optic nerve sheath in intracranial hypertension
    Alvarez-Fernandez, J. A.
    Martin-Pellicer, A.
    de la Cal, M. A.
    MEDICINA INTENSIVA, 2014, 38 (02) : 129 - 129
  • [38] Measuring Optic Nerve Sheath Diameter as a Proxy for Intracranial Pressure
    Aggarwal, Sahil
    Knight, Darren K.
    Boisvert, Chantal J.
    JAMA OPHTHALMOLOGY, 2018, 136 (11) : 1310 - 1310
  • [39] THE EFFECTS OF FLUCTUATING INTRACRANIAL PRESSURE ON OPTIC NERVE SHEATH DIAMETER
    Lasseigne, Lindsay M.
    Wilson, Jason D.
    Butts, Christine
    JOURNAL OF NEUROTRAUMA, 2018, 35 (16) : A110 - A111
  • [40] Comment on "Measuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension"
    De Luca, Martina
    Biondino, Danilo
    Gioia, Marco
    La Marca, Aniello
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2023, 81 (06) : 610 - 611