High-resolution MRI assessment of optic nerve sheath diameter in adults: optic nerve sheath variation and a new diagnostic tool for intracranial hypertension

被引:13
|
作者
Zheng, Ying-mei [1 ]
Hao, Da-peng [2 ]
Tang, Guo-zhang [3 ]
Zhou, Rui-zhi [2 ]
Pang, Jing [2 ]
Dong, Cheng [2 ]
机构
[1] Qingdao Univ, Affiliated Hosp, Hlth Management Ctr, Qingdao, Peoples R China
[2] Qingdao Univ, Affiliated Hosp, Dept Radiol, 16 Jiangsu Rd, Qingdao 266000, Peoples R China
[3] Qingdao Univ, Affiliated Hosp, Dept Cardiac Ultrasound, Qingdao, Peoples R China
关键词
Optic nerve; intracranial hypertension; magnetic resonance imaging; PEDIATRIC-PATIENTS; ULTRASONOGRAPHY;
D O I
10.1177/0284185120966715
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Assessment of optic nerve sheath diameter (ONSD) is a non-invasive measure of intracranial pressure (ICP). However, it is not clear whether healthy individuals exhibit ONSD variation or whether factors other than ICP affect the ONSD. Purpose To investigate whether ONSD was correlated with age, sex, height, weight, eyeball transverse diameter (ETD), or body mass index (BMI), and to develop a new diagnostic model to increase the diagnostic accuracy of intracranial hypertension (IH). Material and Methods A total of 145 relatively healthy adults and 40 patients with acute IH who underwent high-resolution magnetic resonance imaging (MRI) were enrolled in this study. Linear regression analyses were used to determine the relationship between ONSD and these variables. If correlations were identified, an index ONSD (Delta) removing variables effects was calculated. ROC analysis was used to assess the IH predictive value of ONSD Delta in terms of sensitivity and specificity. Results In relatively healthy adults, there was a correlation between ONSD and BMI (P = 0.002), which can be presented as an index ONSD Delta. The ONSD Delta model better predicted IH than the ONSD model (P = 0.035), with a sensitivity of 70.00%, a specificity of 71.72%, and an AUC of 0.755. Conclusion A correlation between ONSD and body mass index (BMI) was found using high-resolution MRI. This result indicates that the effects of BMI should be considered along with the ONSD during ICP monitoring. Meanwhile, the index ONSD Delta was better than the ONSD in predicting IH and could be used to obtain a more precise estimation of ICP.
引用
收藏
页码:1397 / 1403
页数:7
相关论文
共 50 条
  • [1] Diagnostic Significance of Measurement of Optic Nerve Sheath Diameter in Intracranial Hypertension
    Arjun Nair, Lakshmi
    Joshi, Karan
    INDIAN JOURNAL OF PEDIATRICS, 2024, 91 (12): : 1303 - 1303
  • [2] US and MRI guided assessment of the optic nerve sheath diameter in idiopathic intracranial hypertension
    Elsaid, N.
    Belal, T.
    Razek, A.
    Azab, A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2022, 29 : 202 - 202
  • [3] Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension
    del Saz-Saucedo, Pablo
    Redondo-Gonzalez, Olga
    Mateu-Mateu, Angel
    Huertas-Arroyo, Rafael
    Garcia-Ruiz, Rafael
    Botia-Paniagua, Enrique
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2016, 361 : 122 - 127
  • [4] Optic nerve sheath diameter and intracranial pressure
    Dubourg, Julie
    Javouhey, Etienne
    Messerer, Mahmoud
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 570 - 571
  • [5] Evaluating the optic nerve stiffness and optic nerve sheath diameter in idiopathic intracranial hypertension patients after the resolution of papilledema
    Kaya, Fatma Selin
    Bayram, Ersoy
    Inci, Ercan
    NEUROLOGICAL SCIENCES, 2021, 42 (12) : 5165 - 5170
  • [6] Evaluating the optic nerve stiffness and optic nerve sheath diameter in idiopathic intracranial hypertension patients after the resolution of papilledema
    Fatma Selin Kaya
    Ersoy Bayram
    Ercan İnci
    Neurological Sciences, 2021, 42 : 5165 - 5170
  • [7] Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs
    Mija, R.
    Zubak, I
    Schuetz, A.
    Glas, M.
    Fung, C.
    Jakob, S. M.
    Beck, J.
    Z'Graggen, W. J.
    Bloch, Andreas
    PLOS ONE, 2020, 15 (02):
  • [8] Ultrasonographic Assessment of Optic Nerve Sheath Diameter as a Screening Tool for Intracranial Hypertension in Traumatic Brain Injury
    Lioi, Francesco
    Ramm-Pettersen, Jon
    Fratini, Andrea
    Riva, Camilla
    Colella, Niccolo
    Missori, Paolo
    WORLD NEUROSURGERY, 2024, 192 : E42 - E48
  • [9] Sonographic evaluation of optic nerve sheath diameter in idiopathic intracranial hypertension
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 73 : 331 - 332
  • [10] Sonographic assessment of the optic nerve sheath in idiopathic intracranial hypertension
    Baeuerle, Jochen
    Nedelmann, Max
    JOURNAL OF NEUROLOGY, 2011, 258 (11) : 2014 - 2019