The Contribution of Measuring the Optic Nerve Sheath Diameter by using Ultrasonography to the Diagnosis and Monitoring of Intracranial Hypertension

被引:0
|
作者
Kendir, Ozlem Tolu [1 ]
Yilmaz, Hayri Levent [1 ]
Ozkaya, Ahmet Kagan [1 ]
Gokay, Sinem Sari [1 ]
Bilen, Sevcan [1 ]
机构
[1] Cukurova Univ, Pediat, Emergency Care Unit, Balcali Hosp, Adana, Turkey
来源
关键词
Optic nerve sheath diameter measurement; intracranial hypertension; ultrasonography; OCULAR ULTRASOUND; IDENTIFICATION; ONSD; ICP;
D O I
10.33706/jemcr.522919
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Intracranial hypertension, which may have a number of different causes, is a medical emergency. Although difficult to identify due to non-specific symptoms, it must be treated appropriately. An early sign of intracranial hypertension is an increase is observed in the optic nerve sheath diameter.. Ultrasonography is a rapid and easy-to-apply method to detect an increase in optic nerve sheath diameter, and may be useful for the emergency diagnosis and treatment, as well as contributing to clinical follow-up. Case Presentation: In the present study, seven patients with clinical suspicion for rapid intracranial pressure were admitted. Clinical scenarios included traffic accident, metabolic imbalance, infection, and intracranial mass. The pediatric emergency specialist performed optic nerve sheath measurement by using ultrasonography and a dilatation was detected. All measurements were taken by the certified and experienced pediatric emergency specialist blinded to the patient's clinical state and also the specialist was under observation of a lecturer during the measurements. Except for one patient, the control optic sheath diameter measurements were performed in the period, when they had no complaint, and the values were determined to be normal. To our knowledge, this case series is the first one examined in Turkey. The data from cases was collected between 2015 and 2016. Conclusion: Optic nerve sheath diameter measurement is a non-invasive method that offers ease of diagnosis and follow-up of suspected intracranial hypertension.
引用
收藏
页码:21 / 25
页数:5
相关论文
共 50 条
  • [1] Measuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension
    Dagdelen, Kenan
    Ekici, Merve
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2022, 80 (06) : 580 - 585
  • [2] Comment on "Measuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension"
    De Luca, Martina
    Biondino, Danilo
    Gioia, Marco
    La Marca, Aniello
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2023, 81 (06) : 610 - 611
  • [3] Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension
    del Saz-Saucedo, Pablo
    Redondo-Gonzalez, Olga
    Mateu-Mateu, Angel
    Huertas-Arroyo, Rafael
    Garcia-Ruiz, Rafael
    Botia-Paniagua, Enrique
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2016, 361 : 122 - 127
  • [4] Measuring optic nerve sheath diameter using ultrasonography for the detection of non invasive intracranial pressure: what it is and what it is not
    Robba, Chiara
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2022, 80 (06) : 547 - 549
  • [5] Measuring Optic Nerve Sheath Diameter as a Proxy for Intracranial Pressure
    Hoffman, Robert S.
    JAMA OPHTHALMOLOGY, 2018, 136 (11) : 1309 - 1309
  • [6] ULTRASONOGRAPHY OF OPTIC NERVE SHEATH DIAMETER (ONSD) FOR RAISED INTRACRANIAL PRESSURE
    Siddiqui, Naveed Ur Rehman
    CRITICAL CARE MEDICINE, 2018, 46 (01) : 397 - 397
  • [7] Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection
    Wang Li-Juan
    Chen Hong-Xiu
    Chen Ying
    Yu Ze-Yang
    Xing Ying-Qi
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2020, 7 (05): : 865 - 868
  • [8] Ultrasonography of the optic nerve sheath diameter
    Simicevic, D. Sodec
    Lovrencic-Huzjan, A.
    Popovic, I. Martinic
    Cvetkovic, V. Vukovic
    Strineka, M.
    Demarin, V.
    JOURNAL OF NEUROLOGY, 2011, 258 : 225 - 225
  • [9] Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure
    Kim, Dae Yong
    Kim, Sin Young
    Hong, Dae Young
    Sung, Bo Youn
    Lee, Sung
    Paik, Jin Hui
    Jung, Hyun Min
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 204
  • [10] Measuring Optic Nerve Sheath Diameter as a Proxy for Intracranial Pressure Reply
    Wang, Li-juan
    Chen, Hong-xiu
    Xing, Ying-qi
    JAMA OPHTHALMOLOGY, 2018, 136 (11) : 1311 - 1312