Investigation of the punching shear behaviors of reinforced concrete slab-steel reinforced concrete L-shaped column connections

被引:0
|
作者
Xue, Jianyang [1 ,2 ]
Zhang, Wei [1 ]
Xu, Jinjun [3 ]
Yuan, Zhen [1 ]
Zhao, Fei [1 ]
Zhang, Chong [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, 13 Yanta Rd, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian, Peoples R China
[3] Nanjing Univ Technol, Coll Civil Engn, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
steel reinforced concrete; L-shaped column; slab-column connection; punching shear performance; inverted T-shaped steel; FINITE-ELEMENT-ANALYSIS; FLAT SLABS; RESISTANCE; STRENGTH;
D O I
10.1177/13694332221109035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the punching behaviors of reinforced concrete (RC) slab-steel reinforced concrete (SRC) L-shaped column connections, four slab-column connection tests were designed and completed, and a new punching shear resistance measure proposed. The test variables were column section shape, slab thickness and column cap. The test results show that the failure mode of L-shaped column was mainly two-way shear. Meanwhile, increasing slab thickness and installing column cap can effectively improve the ultimate bearing capacity of the slab-column connection. The punching angles formed by the punching cone and horizontal direction at the final failure of the connection were between 23.5 degrees and 49.5 degrees. In addition, a numerical simulation analysis was carried out using ABAQUS software, and the effects of various parameters on the performance of slab-column connections were studied. It was found that the change of column section shape will lead to more complex shear stress distribution and stress concentration phenomenon. However, the punching capacity of the special-shaped column was higher than that of the equivalent square column with the same section area. As a new punching shear resistance measure, inverted T-shaped steel can effectively improve the ultimate bearing capacity of the connections. In addition, when the ratio of slab thickness to web width of inverted T-shaped steel was less than 0.75, the failure mode of the connection changed from brittle punching failure to flexural failure.
引用
收藏
页码:2906 / 2921
页数:16
相关论文
共 50 条
  • [41] Seismic Retrofit of Reinforced Concrete Slab-Column Connections Using Shear Bolts
    Bu, Wensheng
    Polak, Maria Anna
    ACI STRUCTURAL JOURNAL, 2009, 106 (04) : 514 - 522
  • [42] Modified strip model for punching-shear strength of FRP-reinforced concrete edge-column slab connections
    Salama, Ahmed E.
    Hassan, Mohamed
    Benmokrane, Brahim
    Ferrier, Emmanuel
    ENGINEERING STRUCTURES, 2020, 216
  • [43] Reinforced concrete slab-column edge connections with openings
    El-Salakawy, EF
    Polak, MA
    Soliman, MH
    ACI STRUCTURAL JOURNAL, 1999, 96 (01) : 79 - 87
  • [44] Punching Shear Resistance of Interior GFRP Reinforced Slab-Column Connections
    Long Nguyen-Minh
    Rovnak, Marian
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (01) : 2 - 13
  • [45] Ductility of reinforced concrete flat slab-column connections
    Polak, MA
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2005, 20 (03) : 184 - 193
  • [46] Mechanical Behaviors of Reinforced Concrete L-shaped Columns Subjected to High Temperature
    Xu Yuye
    Luo Yi
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL VII, PTS A AND B, 2008, 7 : 1814 - 1819
  • [47] Reinforced L-Shaped Frame Made of Textile-Reinforced Concrete
    Zalsky, Jiri
    Vlach, Tomas
    Repka, Jakub
    Hajek, Jakub
    Hajek, Petr
    POLYMERS, 2023, 15 (02)
  • [48] Performance of reinforced concrete flat slab strengthened with CFRP for punching shear
    Ghayeb, Haider Hamad
    Atea, Rafid Saeed
    Al-Kannoon, Muslim Abdul-Ameer
    Lee, Foo Wei
    Wong, Leong Sing
    Mo, Kim Hung
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 18
  • [49] MECHANICAL BEHAVIOR OF STEEL REINFORCED CONCRETE L-SHAPED COLUMN UNDER LOW CYCLIC REVERSED LOADING
    Chen, Zong-Ping
    Xue, Jian-Yang
    Su, Yi-Sheng
    Zhao, Hong-Tie
    ISISS '2009: INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2009, : 695 - 700
  • [50] Deformation limits of L-shaped reinforced concrete shear walls: Experiment and evaluation
    Han, Xiaolei
    Chen, Binbin
    Ji, Jing
    Xie, Shunguang
    Lu, Huaikun
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (13):