Investigation of the punching shear behaviors of reinforced concrete slab-steel reinforced concrete L-shaped column connections

被引:0
|
作者
Xue, Jianyang [1 ,2 ]
Zhang, Wei [1 ]
Xu, Jinjun [3 ]
Yuan, Zhen [1 ]
Zhao, Fei [1 ]
Zhang, Chong [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, 13 Yanta Rd, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian, Peoples R China
[3] Nanjing Univ Technol, Coll Civil Engn, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
steel reinforced concrete; L-shaped column; slab-column connection; punching shear performance; inverted T-shaped steel; FINITE-ELEMENT-ANALYSIS; FLAT SLABS; RESISTANCE; STRENGTH;
D O I
10.1177/13694332221109035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the punching behaviors of reinforced concrete (RC) slab-steel reinforced concrete (SRC) L-shaped column connections, four slab-column connection tests were designed and completed, and a new punching shear resistance measure proposed. The test variables were column section shape, slab thickness and column cap. The test results show that the failure mode of L-shaped column was mainly two-way shear. Meanwhile, increasing slab thickness and installing column cap can effectively improve the ultimate bearing capacity of the slab-column connection. The punching angles formed by the punching cone and horizontal direction at the final failure of the connection were between 23.5 degrees and 49.5 degrees. In addition, a numerical simulation analysis was carried out using ABAQUS software, and the effects of various parameters on the performance of slab-column connections were studied. It was found that the change of column section shape will lead to more complex shear stress distribution and stress concentration phenomenon. However, the punching capacity of the special-shaped column was higher than that of the equivalent square column with the same section area. As a new punching shear resistance measure, inverted T-shaped steel can effectively improve the ultimate bearing capacity of the connections. In addition, when the ratio of slab thickness to web width of inverted T-shaped steel was less than 0.75, the failure mode of the connection changed from brittle punching failure to flexural failure.
引用
收藏
页码:2906 / 2921
页数:16
相关论文
共 50 条
  • [1] PUNCHING SHEAR BEHAVIOR OF REINFORCED SLAB-COLUMN CONNECTIONS WITH STEEL FIBER CONCRETE - DISCUSSION
    GESUND, H
    SWAMY, RN
    ALI, SAR
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1983, 80 (04): : 358 - 359
  • [2] PUNCHING SHEAR BEHAVIOR OF REINFORCED SLAB-COLUMN CONNECTIONS MADE WITH STEEL FIBER CONCRETE
    SWAMY, RN
    ALI, SAR
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1982, 79 (05): : 392 - 406
  • [3] Punching shear strength of interior concrete slab-column connections reinforced with steel fibers
    Choi, Kyoung-Kyu
    Taha, Mahmoud M. Reda
    Park, Hong-Gun
    Maji, Arup K.
    CEMENT & CONCRETE COMPOSITES, 2007, 29 (05): : 409 - 420
  • [4] Punching shear strength of corroded reinforced concrete slab-column connections
    Qian, Kai
    Li, Jin-Song
    Huang, Ting
    Weng, Yun-Hao
    Deng, Xiao-Fang
    JOURNAL OF BUILDING ENGINEERING, 2022, 45
  • [5] Punching Shear Capacity Analysis of Reinforced Concrete Slab-column Connections
    Guo, Huiyong
    Cheng, Jinjun
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ADVANCED ENGINEERING MATERIALS AND TECHNOLOGY, 2015, 38 : 244 - 248
  • [6] Analysis on punching shear behavior of an innovative connection between T-shaped steel reinforced concrete column and reinforced concrete slab
    Xue J.
    Zhang W.
    Zhang C.
    Zhao F.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2023, 56 (06): : 1 - 13
  • [7] Punching shear performance of reinforced concrete slab-to-steel column connections incorporating ECC and UHPECC
    Hamoda, Ahmed
    Abadel, Aref A.
    Ahmed, Mizan
    Wang, Vincent
    Vrcelj, Zora
    Liang, Qing Quan
    ENGINEERING STRUCTURES, 2025, 322
  • [8] Experimental and numerical investigation of punching shear capacity of corroded reinforced concrete slab-column connections
    Qian, Kai
    Liu, Jin-Ge
    Yu, Xiao-Hui
    Weng, Yun-Hao
    STRUCTURES, 2022, 43 : 1548 - 1557
  • [9] Punching shear strength of reinforced concrete transfer slab-column connections with shear reinforcement
    Kang, Su-Min
    Na, Su-Jeong
    Hwang, Hyeon-Jong
    ENGINEERING STRUCTURES, 2021, 243
  • [10] Numerical study on the punching shear strength of edge steel-reinforced concrete slab-column connections
    Gouda, Ahmed
    RESULTS IN ENGINEERING, 2025, 25