Investigation of the punching shear behaviors of reinforced concrete slab-steel reinforced concrete L-shaped column connections

被引:0
|
作者
Xue, Jianyang [1 ,2 ]
Zhang, Wei [1 ]
Xu, Jinjun [3 ]
Yuan, Zhen [1 ]
Zhao, Fei [1 ]
Zhang, Chong [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, 13 Yanta Rd, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian, Peoples R China
[3] Nanjing Univ Technol, Coll Civil Engn, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
steel reinforced concrete; L-shaped column; slab-column connection; punching shear performance; inverted T-shaped steel; FINITE-ELEMENT-ANALYSIS; FLAT SLABS; RESISTANCE; STRENGTH;
D O I
10.1177/13694332221109035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the punching behaviors of reinforced concrete (RC) slab-steel reinforced concrete (SRC) L-shaped column connections, four slab-column connection tests were designed and completed, and a new punching shear resistance measure proposed. The test variables were column section shape, slab thickness and column cap. The test results show that the failure mode of L-shaped column was mainly two-way shear. Meanwhile, increasing slab thickness and installing column cap can effectively improve the ultimate bearing capacity of the slab-column connection. The punching angles formed by the punching cone and horizontal direction at the final failure of the connection were between 23.5 degrees and 49.5 degrees. In addition, a numerical simulation analysis was carried out using ABAQUS software, and the effects of various parameters on the performance of slab-column connections were studied. It was found that the change of column section shape will lead to more complex shear stress distribution and stress concentration phenomenon. However, the punching capacity of the special-shaped column was higher than that of the equivalent square column with the same section area. As a new punching shear resistance measure, inverted T-shaped steel can effectively improve the ultimate bearing capacity of the connections. In addition, when the ratio of slab thickness to web width of inverted T-shaped steel was less than 0.75, the failure mode of the connection changed from brittle punching failure to flexural failure.
引用
收藏
页码:2906 / 2921
页数:16
相关论文
共 50 条
  • [31] Fire resistance of reinforced concrete column with L-shaped cross section
    State Key Laboratory of Subtropic Architecture Science, South China Univ. of Tech., Guangzhou 510640, China
    Huanan Ligong Daxue Xuebao, 2007, 7 (110-115+130):
  • [32] Rehabilitation of reinforced concrete slab-column connections
    El-Salakawy, EF
    Polak, MA
    Soudki, KA
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (04) : 602 - 611
  • [33] Shear punching studies on an impact loaded reinforced concrete slab
    Saarenheimo, Arja
    Tuomala, Markku
    Calonius, Kim
    NUCLEAR ENGINEERING AND DESIGN, 2015, 295 : 730 - 746
  • [34] Curvature ductility of reinforced concrete column with l-shaped crosse section
    Department of Civil Engineering, South China University of Technology, Guangzhou 510640, China
    Huanan Ligong Daxue Xuebao, 2009, 6 (136-141+146):
  • [35] ESTIMATING THE PUNCHING SHEAR CAPACITY OF VOIDED REINFORCED CONCRETE SLAB
    Vu, Quoc Anh
    Mai, Viet Chinh
    INTERNATIONAL JOURNAL OF GEOMATE, 2024, 27 (124): : 128 - 135
  • [36] Punching shear strength of flat slab corner column connections. Part 2. Fibre-reinforced concrete connections
    Indian Inst of Science, Bangalore, India
    Proc Inst Civ Eng Struct Build, 1 (21-26):
  • [37] Flexurally-triggered punching shear failure of reinforced concrete slab-column connections reinforced with headed shear studs arranged in orthogonal and radial layouts
    Dam, Thai X.
    Wight, James K.
    ENGINEERING STRUCTURES, 2016, 110 : 258 - 268
  • [38] Seismic behavior and strength of L-shaped steel reinforced concrete column- concrete beam planar and spatial joints
    Chen, Zongping
    Xu, Deyi
    Xu, Jinjun
    Wang, Ni
    STEEL AND COMPOSITE STRUCTURES, 2021, 39 (03): : 337 - 352
  • [39] Calculate model study on punching shear strength of reinforced concrete flat plate-special-shaped column connections
    Guangzhou Design Institute, Guangzhou 510620, China
    不详
    Jianzhu Jiegou Xuebao, 2006, SUPPL. (159-162):
  • [40] Bearing capacity assessment of reinforced concrete slab -special-shaped column connections
    Zhang, Wei
    Xue, Jianyang
    Xu, Jinjun
    Li, Baoxin
    Wei, Jinghui
    ADVANCES IN CONCRETE CONSTRUCTION, 2022, 14 (06) : 401 - 412