Investigation of the punching shear behaviors of reinforced concrete slab-steel reinforced concrete L-shaped column connections

被引:0
|
作者
Xue, Jianyang [1 ,2 ]
Zhang, Wei [1 ]
Xu, Jinjun [3 ]
Yuan, Zhen [1 ]
Zhao, Fei [1 ]
Zhang, Chong [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, 13 Yanta Rd, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian, Peoples R China
[3] Nanjing Univ Technol, Coll Civil Engn, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
steel reinforced concrete; L-shaped column; slab-column connection; punching shear performance; inverted T-shaped steel; FINITE-ELEMENT-ANALYSIS; FLAT SLABS; RESISTANCE; STRENGTH;
D O I
10.1177/13694332221109035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the punching behaviors of reinforced concrete (RC) slab-steel reinforced concrete (SRC) L-shaped column connections, four slab-column connection tests were designed and completed, and a new punching shear resistance measure proposed. The test variables were column section shape, slab thickness and column cap. The test results show that the failure mode of L-shaped column was mainly two-way shear. Meanwhile, increasing slab thickness and installing column cap can effectively improve the ultimate bearing capacity of the slab-column connection. The punching angles formed by the punching cone and horizontal direction at the final failure of the connection were between 23.5 degrees and 49.5 degrees. In addition, a numerical simulation analysis was carried out using ABAQUS software, and the effects of various parameters on the performance of slab-column connections were studied. It was found that the change of column section shape will lead to more complex shear stress distribution and stress concentration phenomenon. However, the punching capacity of the special-shaped column was higher than that of the equivalent square column with the same section area. As a new punching shear resistance measure, inverted T-shaped steel can effectively improve the ultimate bearing capacity of the connections. In addition, when the ratio of slab thickness to web width of inverted T-shaped steel was less than 0.75, the failure mode of the connection changed from brittle punching failure to flexural failure.
引用
收藏
页码:2906 / 2921
页数:16
相关论文
共 50 条
  • [21] Punching Shear Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Slab-Column Interior Connections
    Hussein, Ahmed H.
    El-Salakawy, Ehab F.
    ACI STRUCTURAL JOURNAL, 2018, 115 (04) : 1075 - 1088
  • [22] Punching shear strength of flat slab corner column connections .2. Fibre-reinforced concrete connections
    Desayi, P
    Seshadri, HK
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1997, 122 (01) : 21 - 26
  • [23] Shear behavior of steel reinforced concrete column-steel beam joints with or without reinforced concrete slab
    Chu, Liusheng
    Tian, Ye
    Li, Danda
    He, Yuexi
    Feng, Hu
    JOURNAL OF BUILDING ENGINEERING, 2021, 35
  • [24] Reinforced concrete slab-column edge connections with shear studs
    El-Salakawy, EF
    Polak, MA
    Soliman, MH
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2000, 27 (02) : 338 - 348
  • [25] Investigation on Shear Capacity of Joints between Steel Reinforced Concrete Special-Shaped Column and Reinforced Concrete Beam
    Xiang, Ping
    Lin, Yipeng
    Huang, Wei
    Ding, Faxing
    Ye, Bailong
    Deng, Zhiheng
    FRONTIERS IN MATERIALS, 2020, 7 (07):
  • [26] Punching shear performance of star-shaped steel plates reinforced RC slab-column connections
    Liu, Yang
    Zhang, Wenhao
    Zhou, Meili
    Hou, Wei
    Zhang, Yixin
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 19
  • [27] Punching of reinforced and post-tensioned concrete slab-column connections.
    Kang, Thomas H. -K.
    Wallace, John W.
    ACI STRUCTURAL JOURNAL, 2007, 104 (03) : 366 - 367
  • [28] Shear strengthening of reinforced concrete with CFRP L-shaped plates
    Czaderski, Christoph
    EMPA (Swiss Federal Laboratories for Materials Testing and Research) Publication, 2002, (SPEC.RAPORT):
  • [29] Numerical Modelling of the Punching Shear Response of Shearhead Connections between a CFT Column and a Flat Reinforced Concrete Slab
    Nguyen-The, Danh
    Thai, Son
    Nguyen-Van, Hieu
    Ngo-Huu, Cuong
    STRUCTURAL ENGINEERING INTERNATIONAL, 2024,
  • [30] Punching Shear Performance of Reinforced Concrete Slab-Column Joints with Shearhead Reinforcement
    Jiang, Yi
    Li, Yan
    Zhou, Jing
    Yi, Weiwen
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2024, 22 (10) : 1893 - 1918